• Title/Summary/Keyword: 정적 하중 시험

Search Result 266, Processing Time 0.033 seconds

Static Behavior Analysis of Spillway Pier for Dam Safety Evaluation (댐 안전성 평가를 위한 여수로 피어부의 정적 거동 분석)

  • Jang, Bong-Seok;Lim, Jeong-Yeul;Lee, Myung-Kue;Lee, Hyung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.11-18
    • /
    • 2007
  • Seismic performance evaluation for dam safety evaluation has been continually conducted. However the behavior analysis for the spillway pier which is known as the weak point of dam is seldom reported. Therefore, this study performed the static loading tests for a prototype structures as elementary tests for the final seismic performance evaluation of dam safety. The prototype of pier structure has 1/20 scale and it adopts to strength model. And cracking loads and ultimate loads of real structures are calculated through numerical analysis using commercial FEM program (ABAQUS). The results of this study show some difference between the results of prototype tests and the results of numerical analysis. Also, the ultimate and cracking loads can be estimated through the prototype loading test and numerical analysis.

Structural Static Test for Validation of Structural Integrity of Fuel Pylon under Flight Load Conditions (비행하중조건에서 연료 파일런의 구조 건전성 검증을 위한 구조 정적시험)

  • Kim, Hyun-gi;Kim, Sungchan;Choi, Hyun-kyung;Hong, Seung-ho;Kim, Sang-Hyuck
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.97-103
    • /
    • 2022
  • An aircraft component can only be mounted on an aircraft if it has been certified to have a structural robustness under flight load conditions. Among the major components of the aircraft, a pylon is a structure that connects external equipment such as an engine, and external attachments with the main wing of an aircraft and transmits the loads acting on it to the main structure of the aircraft. In civil aircraft, when there is an incident of fire in the engine area, the pylon prevents the fire from spreading to the wings. This study presents the results of structural static tests performed to verify the structural robustness of a fuel pylon used to mount external fuel tank in an aircraft. In the main text, we present the test set-up diagram consisting of test fixture, hydraulic pressure unit, load control system, and data acquisition equipment used in the structure static test of the fuel pylon. In addition, we introduce the software that controls the load actuator, and provide a test profile for each test load condition. As a result of the structural static test, it was found that the load actuator was properly controlled within the allowable error range in each test, and the reliability of the numerical analysis was verified by comparing the numerical analysis results and the strain obtained from the structural test at the main positions of the test specimen. In conclusion, it was proved that the fuel pylon covered in this study has sufficient structural strength for the required load conditions through structural static tests.

Conformity Assessment of Vertical Static Stiffness Test Method for Rail Pad (레일패드 정적 수직강성 시험방법의 적합성 평가)

  • Bae, Young-Hoon;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2015
  • The vertical static stiffness of rail pads or baseplate pads, which are important components in rail fastening systems for track safety, is a key factor to determine the total track stiffness and a guideline of quality control in the manufacturing process. The vertical static stiffness can be checked by laboratory testing: test methods are EN 13146-9 and KRS TR 0014, which are widely used in the railway field. In this paper, to correct some problems, namely the preloading step, the unloading level, and the holding time in the loading program in the vertical static stiffness test of EN 13146-9 and KRS TR 0014, domestic and foreign test standards of pads were analyzed and then certain schemes for a vertical static stiffness test were proposed. To assess the reliability of the proposed schemes, the vertical static stiffness tests were performed with 4 pads and the validity of the test results was estimated.

A Study on the Behavior of Steel Pipe Subjected to Vertical Load inSand (사질토 지반에서의 강관 말뚝의 수직거동 연구)

  • 김영수;허노영;김병탁;김대만
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.5-13
    • /
    • 2000
  • 모래지반의 상대밀도, 말뚝의 시공방법, 일정근입깊이에 따른 소요향타 에너지 그리고 지하수 조건에 따라 말뚝의 지지력과 하중전이를 연구하기 위하여 강관말뚝을 이용한 모형실험을 수행하였다. 매입말뚝은 말뚝을 미리 설치한후에 지반성형을 실시하였고, 타입말뚝은 매입말뚝과 같은 깊이까지 항타높이를 5, 10, 15cm로 달리하여 말뚝을 관입하였다. 그 뒤 정적하중을 단계적으로 가하여 하중-침하 곡선에 의한 모형 말뚝의 지지력과ㅏ 말뚝내의 등간격으로 설치된 변형 게이지를 이용하여 타입말뚝 의 하중전이에 대해 살펴보았다. 타입말뚝의 하중전이시험에서는 항타 전과 항타 후 말뚝내 하중전의 소효항타 에너지에 따른 변화를 관찰하였다. 매입말뚝의 시험결과는 현재 가장 많이 사용하고 있는 대표적인 정적 지지력 공식들에 의하여 계산되어진 값들과 비교 분석하였다. 그 결과 상대밀도가 작은 느슨한모래지반에서는 Vesic 공식이 그리고 상대밀도가 큰 조밀한 모래지반에서는 Hanbu 공식이 가장 근접한 평가를 나타내었다. 하중전이시험에 의한 항타시 잔류응력은 모든 경우에서 지표면과 선단부위에서 아주 큰 잔류응력이 나타났고. 말뚝의 선단 지지력비는 상대밀도에 비례하게 증가하였다.

  • PDF

Experimental study on Static Behavior of H-beam prestressed with Multi-Stepwise TPSM (다단계 온도프리스트레싱 도입 강재보의 정적거동평가를 위한 실험적 연구)

  • An, Jin Hee;Jung, Chi Young;Kim, Jun Hwan;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.247-258
    • /
    • 2008
  • In this study, static loading tests were performed on H-beam specimens to assess the static behavior of H-beam prestressed with multi-stepwise thermal prestressing method (TPSM). The amount of induced thermal prestress and connection type were differentiated among the 400-mm-high and 6,000-mm-long H-beam specimens to evaluate their effect on the behavior of the beams. From the experimental results, it between the H-beam and the cover-plate increased in yielding load by 13~18%, whereas stiffness increased by 27~34%. In case of specimens with both bolting and welding connection, yie lding load increased by 18~29% and stiffness increased by 43~51%. Multi-stepwise initial stress distribution was also observed from the prestressed specimens, verifying the effectiveness of the multi-stepwise TPSM. By application of the multi-stepwise TPSM, a significant increase in yielding load and stiffness can be achieved, hence increasing sectional and prestressing efficiencies.

Development of Full-Scale Static Test System for Aircraft Sensor Pod (항공용 센서 포드의 정적 구조시험장비 개발)

  • Jae Myung Cho;Hoon Hyuk Park;Won Woong Lee;Jong In Bae;Han Sol Lee;Eui Hwan Oh
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2023
  • For aviation sensor pod, structural integrity should be verified through static structural tests for flight loads induced in various maneuvering conditions of the aircraft. For this, it is necessary to develop a test system for full-scale static load test of sensor pod. Based on test requirements, this paper introduced a test system configuration of the static test and the development of test structure frame, restraints equipment, loading equipment, control, and measurement equipment. In addition, methods and procedures for verifying the developed test system were explained. In conclusion, the static load test and data acquisition were successfully performed. Reliability of the test equipment was also verified in the process.

Static Test of a Composite Wing with Damage Tolerance Design (손상 허용 설계를 적용한 복합재 날개의 정하중 시험)

  • Park, Min-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.471-478
    • /
    • 2018
  • Static tests of the composite wing structure were performed to verify damage tolerance design. Both 5 cases of DLLT and 3 cases of DULT were completed to meet requirements for static strength. After inducing BVID and open hole damages on the critical areas of the composite wing based on associated regulations, the DULT and fracture test were performed. In major wing parts, the measured strains and displacements agreed well with those of structural analysis. The initial structural fracture occurred at the area having minimum margin of safety as expected by analysis. As a result, it was confirmed that results from analytic model and strength evaluation were similar to behaviors of the composite wing structure.

Static Behavior of Bi Prestressed Concrete Girders (프리스트레스트 콘크리트거더의 정적거동 평가)

  • Lee, Pil-Goo;Kim, Choong-Eon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.357-360
    • /
    • 2008
  • This study was performed to estimate the workability and the static behavior for Bi Prestressed Concrete Girder(Bicon girder) which could introduce effectively prestressed forces into concrete girders. A bicon girder is manufactured by means of introducing pure bending moment that prestress simultaneously the compressive member(steel bar) and the tensile member(steel tendon). Static test was executed for 20m railway bridge girder specimen and evaluated whether pure bending moment was introduced or not, and the behaviors after cracking, and at the ultimate load. Test results showed that a bicon girder had the enough safety in the introduction of pure moment, the serviceability, and the ultimate behavior.

  • PDF

KC-100 Full-scale Airframe Static Test (KC-100 전기체 정적 구조시험)

  • Shim, Jae-Yeul;Jung, Keunwan;Lee, Hanyong;Lee, Sang Keun;Hwang, Gui-Chul;Ahn, Seokmin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.67-75
    • /
    • 2014
  • A full-scale static test for a composite structure small aircraft (KC-100) was conducted in the KARI. The test includes 15 full-scale test and 7 local test conditions. Test requirements with test schedule, test article with dummy structures, test load generation, test system, and equipment are introduced for the test. Test load data of the 1st test condition(U1) was analyzed to evaluate an accuracy of load control for the test. The analysis results show that load data obtained during test were within tolerance of Static Null Pacing Error(SNPE) and the error value of load control was 8.6N. The error of load controls for the full-scale static test using dozens of actuators was calculated by a method suggested by authors. Test data for all other test conditions is also shown in this paper. Finally, reactions measured from restraint system of the U1 test condition show that the reaction changes as load increment. The factors which may change the change of reactions for a full-scale static test are introduced in this study.