Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control (유량제어방식에 따른 태양열 급탕시스템의 열성능 평가)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

A Study on Improved Heating Performance of an Apartment Housing Unit (공동주택 세대별 난방 성능 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

자동차연료의 저 공해화 기술

  • 김경원
    • Journal of the KSME
    • /
    • v.32 no.12
    • /
    • pp.1049-1058
    • /
    • 1992
  • 자동차 공해를 저감하기 위해서는 정부 당국의 도로 여건 개선을 통한 교통 체증의 해소, 자동차 제조기술(연소, 제어, 배기가스 정화등)의 개선, 정유사의 저공해 연료 개발 및 운전자 개개인의 운전 습관 개선, 차량 정비 점검 등 제반 노력이 합치되어야 할 것이다. 이중 연료 측면에서의 대기오염 개선을 위한 저공해화 기술을 요약하면 다음과 같다. 자동차 배기가스에 영향을 미치는 휘발유의 황함량을 낮추면 휘발유 자동차의 유해 배기가스 배출이 전반적으로 감소한다. RVP와 방향족 함량은 낮을수록, 함산소화합물함량은 높을수록 HC와 CO를 저감시키며 특히 CO의 저 감이 현저하다. 90% 증류점을 낮추면 HC 배출량이 크게 감소하고 올레핀함량을 낮추면 $NO_{x$ 배출이 억제된다.

  • PDF

Irradiation and Power Analysis According to Months (태양광 시스템의 월별 일사량과 전력량)

  • Jung, You-Ra;Kim, Seok-Gon;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.205-205
    • /
    • 2009
  • 태양광 발전은 다른 발전방식과는 달리 연료비가 불필요하고 대기오염이나 폐기물 발생이 없으며 부위가 반도체 소자이고 제어부가 전자제품이므로 기계적인 진동과 소음 등의 공해가 전혀 없는 에너지원이다. 그러나 태양광 발전은 에너지 밀도가 낮아 일사량, 온도, 계절 등 기상조건의 작은 변화에도 발전량의 편차가 심하고 출력이 불안정하여 상용전원과의 연계나 별도의 축전설비 또는 발전설비 없이 독립적으로 사용하기에는 다소 무리가 있다는 단점이 있다. 따라서 본 논문에서는 이러한 문제점을 해결하기 위해서 1년 동안 실증운전을 통한 종합적인 운전특성 데이터, 태양전지 어레이 출력의 전압 전류, 교류 전력 및 전력량, 일사량 및 모듈의 온도, 외기온도 등 분석기간 동안 수집된 운전 데이터를 이용하여 태양이 태양전지 모듈에 입사되는 각과 발전량 즉 태양 전지 어레이 형태와 발전량과의 상관관계를 정량적으로 규명하여 태양광 발전시스템의 설계 및 시공의 최적화가 이루어질 수 있도록 하였다.

  • PDF

Removal of Volatile Organic Compounds (VOCs) of Deodorant by Adding a Metal Oxide to the Essential Oils (식물정유물질에 금속산화물을 첨가한 탈취제의 휘발성유기화합물질의 제거에 관한 연구)

  • Lim, You-Young;Lee, Min-Ho;Jeon, Soo-Bin;Yang, Kyeong-Soon;Jeong, Hae-Eun;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.96-105
    • /
    • 2016
  • VOCs emissions from industries cause the air pollution and odor. In the industrial facilities, the existing odor treatment techniques have limits and problems. In this study, the optimum essential oil and metal oxide selected by screening test. lavender oil, cypress oil and TiO2 were determined by deodorant materials and those were blended by 5%, 45%, 10%, respectively. In addition, the result of batch type experiments depending on the dilution rate, injection, rate, temperature showed that the optimum condition of deodorant is 6 mL of injection rate, and 200 times of dilution rate and the removal efficiency increased in proportion with temperature. In addition, the activation energy was calculated from the rate equation, which appeared in the 3-4 times lower than conventional deodorants.

Method and Analysis of Dynamic Simulation for Ondol Heating (온돌 난방에 대한 동적 시뮬레이션 및 분석)

  • Hong, Hi-Ki;Kim, Si-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

Detection and Response scheme against DDOS attack using the cooperation between routers (라우터들간의 협력에 의한 DDOS 공격 탐지 및 대응)

  • Choi, Won-Ju;Jung, Yu-Seok;Hong, Man-Pyo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11b
    • /
    • pp.1143-1146
    • /
    • 2002
  • 1999 년 이후 DDOS 공격에 대한 많은 연구가 이루어지고 있고, 지금까지 많은 대응 방안이 제안되었다. 그 중에서 공격이 이루어질 때 라우터의 최소생존성을 기본 가정으로 하고 라우터의 출력 대역폭를 조절하는 방법이 가장 적합한 방안으로 인식된다. 그러나 실제 희생자주위의 라우터들은 과도한 패킷량으로 인한 생존성을 보장 받기 힘들다. 또한 대역폭 제어만으로는 정상 패킷과 공격 패킷의 구분 없이 전체 트래픽량을 조절하기 때문에, 네트워크 노드들의 보호는 가능하지만, 많은 정상 패킷의 손실로 인한 정상 서비스는 불가능하게 된다. 이러한 문제점을 해결하기 위해서 이웃라우터 상호협력을 통한 공격경로의 묘사 방법과 대응 방법에 있어서 특정패킷집단을 정의하고 패턴 필터링을 통한 공격 패킷의 차단 방안을 제안한다.

  • PDF

Mechanical Properties Evaluation of the Transparent Oxide Thin films for flexible Devices (연성소자용 투명산화물 박막의 기계적 특성 평가)

  • Lee, Seong-Hun;Yun, Jeong-Heum;Jo, Sang-Hyeon;Jeong, Jae-Hye;Jeong, Yu-Jeong;Lee, Geon-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.175-176
    • /
    • 2009
  • 연성 기판을 기초로 하는 플렉서블 디스플레이 등의 연성 소자에 적용되는 TCO, 투습방지막의 기계적 특성을 시험하였다. 실제 사용 환경에서의 기계적 특성을 평가하기 위하여 굽힘시험과 인장시험을 적용하였다. PET 기판위에 PE-CVD 공정으로 성장된 실리콘 산화물 ($SiO_x$) 박막과 그 위에 스퍼터링 공정으로 성장된 투명 전도성 산화물 (TCO, Transparent Conducting Oxide) 박막의 시험 결과, 균열 생성 임계 변형량은 TCO 박막에 의해서 결정됨을 알 수 있었다. 따라서 향상된 기계적 특성을 얻기 위해서는 TCO 박막의 특성 제어가 필요하다.

  • PDF

Adjustment of Valve Opening in Ondol Hot Water Distributor (온돌 난방분배기의 개도조정)

  • Hong, Hi-Ki;Kim, Si-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

A study on the optimized hood design in melting process of casting facilities using CFD (전산유체역학을 이용한 주물 제조 사업장 용해 공정의 최적 후드 설계에 관한 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Jung, Jong-Hyeon;Lim, Ki-Hyuk;Kim, Jin-Uk;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.269-272
    • /
    • 2011
  • 주물 사업장의 용해 공정인 장입과 출탕 작업, 첨가제 투입 과정에서 많은 분진이 발생한다. 실제 주물 사업장에서 사용되는 후드 형태는 매우 다양하며 구조적인 문제점으로 인해 효과적인 배기가 어려운 실정이다. 본 연구를 통해 실제 사업장에 전기로의 다양한 공정 형태에 대한 대응이 가장 우수한 직인식 후드 방식을 제시하고, 전산유체역학(CFD : Computational Fluid Dynamics)을 이용한 오염물질 거동 예측 기법을 활용하여 직인식 후드의 적정 배기량을 산정하여 현장에 제시하였다. 실제 현장에서는 본 개념 설계 결과를 바탕으로 용해 공정에 $400m^3/min$의 배기량을 갖는 직인식 후드를 설치한 결과, 매우 만족스러운 분진 제어 효율을 확인할 수 있었다.