• 제목/요약/키워드: 정유량조절밸브

검색결과 4건 처리시간 0.022초

자동 정유량 온도조절밸브의 스프링 길이가 밸브 용량에 미치는 영향 (Spring Length Effect on the Flow Capacity of automatic Flow-Temperature Control Valve)

  • 유선학;강승덕;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.174-177
    • /
    • 2003
  • The automatic temperature control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have simillar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the automatic flow-temperature control valve was developed. The perfromance of this control valve is effected by the catridge shape and spring length. The flow capacity of this control valve is obtained with the different shape of catridges and with change of spring length.

  • PDF

Y 스트레이너형 자동 정유량 조절 밸브의 개발 (Development of Y Strainer Type Automatic Flow Rate Regulating Valve)

  • 윤준용;권우철
    • 한국유체기계학회 논문집
    • /
    • 제10권1호
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구 (A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings)

  • 차민철;제성호;석호태
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF