• Title/Summary/Keyword: 정상 참고치

Search Result 45, Processing Time 0.134 seconds

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Trace element concentrations profiles in the hair of normal children living in the northern area of Seoul (서울 북부지역에 거주하는 정상 아동의 모발 미네랄 함량)

  • Kwon, Ji Won;Kim, Byung Eui;Park, Mi Jung;Kim, Sang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2006
  • Purpose : The reliability of hair mineral analyses regarding nutritional status, environmental exposure or diseases is controversial. The aim of this study was to determine the normal reference range of hair mineral concentration of Korean children. Methods : We examined hair mineral concentrations of 223 children(3-12 yrs old, 110 boys, 113 girls, mean age $8.8{\pm}2.2$ yrs old) living in the northern area of Seoul. The trace elements including six toxic elements(Al, As, Cd, Ba, Hg, Pb) and 11 nutritional elements(Na, Mg, P, K, Ca, Cr, Mn, Fe, Cu, Zn, Se) were analyzed by inductive coupled plasma mass spectrometry(ICP-MS). Results : The mean concentrations of Ca and Mg were higher in girls than in boys. The mean concentrations of Cd, Pb and Cr were higher in boys than girls. The Zn, Ca, Mg, Cu and Hg levels in hair samples were positively correlated with increasing age. The Zn levels of the Korean children's hair samples appear to be lower than that of other countries' reference values. Conclusion : There are considerable differences in hair mineral concentrations by age, sex and race. Additional research is needed to establish Korean reference values, and to evaluate the usefulness of hair mineral analyses as a screening tool for nutrition- and environment-related childhood diseases.

Evaluation of reference value of anti-Glutamic acid decarboxylase antibody for cerebrospinal fluid (뇌척수액에서 항 Glutamic acid decarboxylase 항체검사의 참고치 설정)

  • Park, Min-Ho;Shin, Sun-Young;Youn, Tae-Seok;Shin, Hi-Jung;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.28-30
    • /
    • 2017
  • Purpose Anti-Glutamic acid decarboxylase antibody test (GAD Ab) has been used as a predictor of type 1 diabetes. GAD Ab has also been shown to be highly potent in cerebrospinal fluid (CSF) of patients with suspected diabetic peripheral neuropathy. Recently, it has been known that clinical significance of GAD Ab using CSF is useful for the neurological disorders. However, the reference value of anti-GAD Ab has been provided only for serum. In this experiment, we estimated the reference value of anti-GAD antibody for CSF in neurological patients. Materials and Methods A total of 211 neurological patients were enrolled. Serum and CSF were analyzed by radioimmunoassay (RIA) using commercial RIA anti-GAD Ab kit (RSR, London, United Kingdom). Normal saline was used as the normal CSF control because CSF is most similar to 0.9% normal saline. Results The mean value of normal CSF control was 1.97 U/mL, and two standard deviations (2SD) was 1.44 U/mL. Based on this data, the expected reference range of CSF could be estimated from 0.54 U/mL to 3.40 U/mL Conclusion The reference range of normal CSF control using normal saline obtained with Hoffmann's method. However, there will be a need to validate the CSF reference values using human normal CSF.

  • PDF

Quantification of Glottal Cycle According to the Variation of Frequency and Intensity in Normal Speaker (발성의 강도와 주파수 변화에 따른 성대 움직임의 정량적 분석)

  • 손영익;이경아;류준선;백정환
    • Proceedings of the KSLP Conference
    • /
    • 1996.11a
    • /
    • pp.92-92
    • /
    • 1996
  • 비디오스트로보스코피 화상의 정량화를 통한 glottal cycle의 객관적인 평가는 여러 질환의 감별 및 치료전후의 결과를 비교하는데 중요한 역할을 담당할 수 있으리라 사려되나 아직은 정상 발성시나 병적인 조건에서의 참고치나 그 의미에 대하여 보고된 경우는 흔치 않은 실정이다. 이에 저자들은 정상성인을 대상으로 발성의 주파수와 강도의 변화에 따른 glottal cycle의 변화를 정량화 함으로써 추후 연구나 임상적용 둥의 기본자료로서 활용하고자 하였다. (중략)

  • PDF

A New Reference Range of Serum Anion Gap (혈청 Anion gap의 새로운 범위에 관한 연구)

  • Shin Young-Ju;Cheon Hae-Won;Choi Byung-Min;Yoo Kee-Hwan;Hong Young-Sook;Lee Joo-Won;Kim Soon-Kyum
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.9-13
    • /
    • 1998
  • Purpose: The old reference range of serum anion gap(AG) may be excessive compared with value measured by new electrolyte analyzers. Therefore, we studied to establish a new reference range of AG using an autoanalyzer. Methods: With the use of analyzer(Hitachi 747 by enzymatic methods), serum Na and Cl were measured, and with the use of analyzer(CX-3 by differental rage pH), serum $TCO_2$ was measured. We measured AG(=Na-($Cl+HCO_3$)) in 395 stable patients with normal serum albumin and creatinine levels of the pediatric in-patients and out-patients for preoperative examination from march 1997 to July 1997. Results: The normal serum$ AG(mean{\pm}SD)$ were neonate, $11.2{\pm}3.2$ mEq/L; infancy, $11.8{\pm}2.7$ mEq/L; early childhood, $12{\pm}2.7$ mEq/L; late childhood, $11.7{\pm}3.2$ mEq/L; adolescence, $9.6{\pm}2.7$ mEq/L; adult, $9.0{\pm}2.7$ mEq/L. Normal serum AG in more than 10 years of age was significantly lower than the previous normal value and also the difference of AG between more than 10 years and less than 10 years was statistically significant(P<0.05). Conclusions: We suggest to measure serum AG according to each type of analyzers.

  • PDF

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Establishment of Reference Intervals of Osteocalcin according to Age in Women for Health Promotion Center (건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정)

  • Kang, Ji-Soon;Yoo, Byoung-Joo;Oh, Jung-Eun;Kim, Geon-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.104-111
    • /
    • 2009
  • Purpose: Osteocalcin is also known as the bone gamma-carboxyglutamic acid (Gla) protein (BGP), is noncollagenous bone protein synthesized by osteoblasts. Serum concentrations of Osteocalcin have been used as a biochemical marker of bone turnover. The reference intervals of Osteocalcin is categorized by kit corporation according to the age. However, each laboratory should establish its own reference intervals. In this study, the variation in the serum Osteocalcin level were used to find actual standard age-specific Osteocalcin reference intervals. Materials and Methods: We have selected 864 healthy females aged 20~80 years who visited a health promotion center between Aug. 2007 and Sep. 2008. The Osteocalcin IRMA Kit (OSTEO-RIACT, CIS Bio international, Gif-sur-Yvette, France) was used for the quantification. Each results were analyzed with the SPSS 12.0 statistical software. Results: The analyzed reference intervals of Osteocalcin by using Hoffmann method are from 8.8~39.4 ng/mL to 6.3~28.8 ng/mL for the case of the age from 20 to 30, from 7.7~31.9 ng/mL to 5.9~17.4 ng/mL for the case of the age from 31 to 40, and from 8.0~36.0 ng/mL to 5.5~20.1 ng/mL for the case of the age from 41 to 50, and from 8.0~50.5 ng/mL to 6.7~27.0 ng/mL for the case of the age from 51 to 60, and from 12.9~55.9 ng/mL to 7.5~27.5 ng/mL for the case of the age from 61 to 80. Reference intervals of Osteocalcin were not in agreement with those recommended by the manufacturers. Conclusions: Osteocalcin is used as an indication of metabolic bone diseases. So in our study we wanted to provide reference intervals of Osteocalcin that can be useful to a clinical decisions. Also, previous reference intervals should not be re-used and new intervals should be set by continuous analyzing.

  • PDF

Cross-calibration of Bone Mineral Density between Two Different Dual X-ray Absorptiometry Systems: Hologic QDR 4500-A and Lunar EXPERT-XL (서로 다른 이중에너지 방사선흡수기계 기종(Hologic QDR 4500-A와 Lunar EXPERT-XL) 간의 골밀도 교차 보정)

  • Jo, Jin-Man;Kim, Jae-Seung;Kim, Ghi-Su;Kim, Sang-Wook;Shin, Jung-Woo;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.282-288
    • /
    • 1999
  • Purpose: A cross-calibration equation is needed to compare bone mineral density measured by different dual X-ray absoptiometry systems. We performed this study to establish appropriate cross-calibration equations between two different dual X-ray absorptiometry systems. Materials and Methods: Bone mineral density of anterior-posterior lumbar spine (L2-4 level) and femoral neck were measured in 109 women ($55{\pm}11yr$) using two different dual X-ray absorptiometry systems (Lunar EXPERT-XL and Hologic QDR 4500-A). Bone mineral density values measured by two systems, including area, bone mass content, bone mineral density and percentile of young normals were compared and cross-calibration equations between two systems derived. Results: The bone mineral density values of 109 women measured by Lunar system were $0.958{\pm}0.17g/cm^2$ at L2-4 and $0.768{\pm}0.131g/cm^2$ at femur neck, which were significantly higher ($13{\pm}6%$ at L2-4 and $19{\pm}7%$ at femur neck, p<0.001) than those ($0.851{\pm}0.144 g/cm^2$ at L2-4 and $0.649{\pm}0.108 g/cm^2$ at femur neck) by Hologic system. Bone mineral content and percentile of young normals measured by Lunar system were also significantly higher than those by Hologic system (p<0.001), whereas there was no difference in area (p>0.05). There was a high correlation between bone mineral density values of L2-4 and femoral neck obtained with both dual X-ray absortiometry systems (r=0.96 and 0.95, respectively). Cross-calibration equations relating the bone mineral density were Lunar= 1.1287${\times}$Hologic -0.0027 for L2-4 and Lunar= 1.1556${\times}$Hologic+0.0182 for femoral neck. Conclusion: We obtained cross-calibration equations of bone mineral density between Lunar EXPERT-XL and Hologic QDR 4500-A. These equations can be useful in comparing bone mineral density obtained by different dual X-ray absorptiometry systems.

  • PDF

진단검사의학 검체검사의 정상치와 참고치

  • Lee, Gap-No
    • Journal of Korea Association of Health Promotion
    • /
    • v.1 no.1
    • /
    • pp.19-20
    • /
    • 2003
  • In Korea association of health promotion(KHAP) there are fourteen laboratories in branch offices and one laboratory in headquarter office. To standardize the reference ranges of all laboratories of KAHP, they have been newly calculated from the laboratory data perfomed during the previous yearsby statistical metod annually for the period of 2000 through2003 so far. The referance ranges of total 56 test items were assigned. Among these there were eight test items that needed referance ranges by age groups and nine test items that needed reference rages by gender. The age grouping was into six groups : baby (0-3y), children(4-12y), adolescent(13-18y), adult(19-64y), younger elderly(19-64y), older elderly(over 80y) with references of statics in Medical Informatics and WHO classification. All the data collected were statistically analyzed with SAS 6.04 for Gaussian distribution that had been repeated two or three times after trimming out the the tests showed Gaussian distribution. Subsequently, Thereference ranges were defined in the rage from the point of lower 2.5% to the point of higher 97.5%. And in case the lower range could be "0", the reference ranges were defined in the range of 0 to 95%. Fifteen laboratoried troughout Korea of KAHP currently have standarzed reference rages of the tests that they perform. This means the patient data and reference values an be exchangeable among laboratories of KHAP.Annual revise of such reference rages can eventually lead to the level of those representing a standard of the national reference ranges.

  • PDF

Quantitative Analysis of Glottal Cycles According to Frequency and Intensity Variations in Normal Speakers (발성의 강도와 주파수 변화에 따른 성대 움직임의 정량적 분석)

  • Young-Ik Son;Kyungah Lee;Jun-Sun Ryu;Chung-Hwan Baek
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.5-11
    • /
    • 1997
  • To set up an objective basis for the evaluation of the stroboscopic findings, video-strobolaryngoscopic images of vocal fold vibration in 5 female and 5 male normal speakers were analyzed using an image analysis computer program called KSIP(Kay Storoboscopy Image Processing, Kay Elemetrics Corp., NJ, USA). Four consecutive vibratory cycles were compared in comfortable, louder, high-pitched /ee/ phonation for every subject. findings mostly replicated earlier studies including glottal chinks which were observed in most female speakers throughout the cycles and clear distinction between female and male speakers in their vibratory patterns as well as intensity and frequency-re-lated differences. However, there were some findings incompatible with those from previous studies which may be attributable to technical problems. This study may provide an objective basis of the stroboscopic findings such as image shape, amplitude, area, and their changes according to frequency and intensity variations. We anticipate that funker study with larger samples ran provide an objective criteria for normal vibratory characteristics of the laryngostro-boscopic findings.

  • PDF