• Title/Summary/Keyword: 정상상태 오차

Search Result 353, Processing Time 0.022 seconds

Rainfall Prediction of Seoul Area by the State-Vector Model (상태벡터 모형에 의한 서울지역의 강우예측)

  • Chu, Chul
    • Water for future
    • /
    • v.28 no.5
    • /
    • pp.219-233
    • /
    • 1995
  • A non-stationary multivariate model is selected in which the mean and variance of rainfall are not temporally or spatially constant. And the rainfall prediction system is constructed which uses the recursive estimation algorithm, Kalman filter, to estimate system states and parameters of rainfall model simulataneously. The on-line, real-time, multivariate short-term, rainfall prediction for multi-stations and lead-times is carried out through the estimation of non-stationary mean and variance by the storm counter method, the normalized residual covariance and rainfall speed. The results of rainfall prediction system model agree with those generated by non-stationary multivariate model. The longer the lead time is, the larger the root mean square error becomes and the further the model efficiency decreases form 1. Thus, the accuracy of the rainfall prediction decreases as the lead time gets longer. Also it shows that the mean obtained by storm counter method constitutes the most significant part of the rainfall structure.

  • PDF

Gain clamping system of erbium-doped fiber amplifier using differential ASE monitoring (WDM용 EDFA의 이득조절 시스템을 구현하기 위한 ASE 차동 감시 방법에 대한 연구)

  • 윤호성;배성호;박재형;박남규;안성준
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2000
  • This paper presents a simple but novel gain deviation detector scheme which can be used for general gain-clamping systems. By using the difference of ASEJprobe powers extracted from the edges of gain-flattened bandwidth, gain deviation of EDFA can be exactly detected regardless of the operating condition of a constructed EDFA. To prove the vahd1ty of the suggested scheme, we Implemented gain clamping systems on a single EDFA and cascaded EDFA's link and achieved sufficient gam-clamping performance without the elaborate measurement for tlIe determination of control parameters. eters.

  • PDF

Sinusoidal Tracking Control of Voltage Source PWM Converter by Input Current Estimation (입력전류추정에 의한 전압형 PWM 컨버터의 정현추종제어)

  • 허태원;박지호;신동률;김춘삼;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2000
  • This paper presents the sinusoidal tracking controller in error to eliminate the steady state control error and to improve the transient characteristics for input current in voltage source PWM converter with input current estimation. The estimation method of input current values and configuration of controller are described. DC output voltage is controlled by PI controller, and sinusoidal tracking current controller which tracks directly AC input current is used as input current controller. The sinusoidal tracking current controller can be used without any coordinate transformation algorithms.It is proved that the steady state deviation of input current reduces to zero and the proposed control system is not affected by input voltage from transfer functions of input current control system. The validity of proposed scheme is verified by simulations and experimental results for load resister and input voltage variation.

  • PDF

Single-Phase Utility-Interactive Inverter for Residential Fuel Cell Generation System (가정용 연료전지 발전 시스템을 위한 단상 계통연계형 인버터)

  • Jung, Sang-Min;Bae, Young-Sang;Yu, Tae-Sik;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • In this paper, a new single-phase utility-interactive inverter system for residential power generation with fuel cell is proposed. The proposed inverter system is not only capable of working in both stand-alone and grid-connected mode, but also ensures smooth and automatic transfer between the two modes of operation. The proposed control method has little steady-state error and good transient response characteristic. Also, the control method can be implemented using low-cost, fixed point DSP since it has simpler structure, smaller amount of calculation, and smaller number of sensors. The controller for the proposed utility-interactive inverter system is described, and the validity is verified through simulation and experiment.

Design of a Integral Sliding Mode Speed Controller having Chattering Alleviation Characteristics for the Sinusoidal type Brushless DC Motor (채터링 저감특성을 갖는 정현파형 브러시리스 직류전동기 (BLDC Motor)의 적분 슬라이딩 모드 속도제어기 설계)

  • Kim, Sei-Il;Choi, Jung-Keyng;Park, Seung-Yub
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.2
    • /
    • pp.1-11
    • /
    • 2001
  • In this paper, a chattering alleviation VSS controller for the sinusoidal type BLDC motor is designed. Dead Zone function is proposed to change the chattering occurring in the transient state from high frequency to low frequency and time varying gains arc applied for the control input to eliminate the steady state excessive chattering in the conventional ISM. The proposed Dead Zone function represents the sliding layer composed of two switching surfaces and if a state vector exists in this layer, the chattering don't occur. Simulation and experimental results confirm the useful effects of the above algorithm.

  • PDF

A Convergence Analysis of Normalized Sign Algorithm for Adaptive Noise Canceler (적응잡음제거기를 위한 정규 부호화 알고리즘의 수렴특성 분석)

  • 김현태;박장식;배종갑;손경식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1203-1210
    • /
    • 1999
  • Coefficients of the adaptive filter are misadjusted by primary signals which are uncorrelated with reference signals of the adaptive filter. In this paper, the normalized sign algorithm is analyzed and compared with the NLMS algorithm by the steady state performance and the transient characteristics when target signals are included in primary signals. The excess mean square error of the NLMS algorithm is proportional to the power of target signals. That of normalized sign algorithm is proportional to the square root of the target signal power. However, the convergence speed of the normalized sign algorithm is slower than that of NLMS algorithm. In this paper, it is shown that theoretical analysis of the steady state performance and the transient characteristics are well consisted with the results of computer simulation.

  • PDF

Quantifying the Variation of Mass Flow Rate generated by Pressure Fluctuation (압력섭동에 의한 유량변동 측정 정량화)

  • Khil, Tae-Ock;Kim, Dong-Jun;Cho, Seong-Ho;Ahn, Kyu-Bok;Han, Yeoung-Min;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.152-156
    • /
    • 2007
  • It is very important to understand about mass flow rate variations of propellants generated by pressure fluctuation in the combustion chamber. Therefore, we have studied quantifying the variation of mass flow rate generated by pressure fluctuation. The flow velocity in orifice is acquired through theoretical approach after measuring the pressure in orifice and the flow area in orifice is measured by film thickness measuring device. Our results agreed with it in the very small error range comparing our results with velocity and mass flow rate in steady state. Thus, our result based on theoretical approach will help about measuring mass flow rate in non-steady state.

  • PDF

A Study on Driving Algorithm of Single-phase PMSM based on Proportional Resonant Current Controller (비례공진 전류제어기 기반의 단상 영구자석 동기전동기 운전에 관한 연구)

  • Seong, Uiseok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.1
    • /
    • pp.115-120
    • /
    • 2021
  • In this paper, an operating algorithm for single-phase permanent magnet synchronous motor based on PR current controller is proposed. In general, an asymmetric gap may occur depending on the shape of the rotor of single-phase PMSM, and this causes noise and vibration during high-speed operation. Therefore, in this paper, an operating algorithm for a single-phase PMSM usihng a proportional resonant current conrtoller with excellent control stability was proposed. Proportional resonant current controller has on steady state error is relatevly robust against distortion. Also, steady state error of AC input can be eleminated without complicated calculation process. The validity and availability of the proposed algorithm are verified through the experiment.

Performance Evaluation of a Switch Router with Output-Buffer (출력 버퍼를 장착한 스위치 라우터의 성능 분석)

  • Shin Tae-zi;Yang Myung-kook
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.2
    • /
    • pp.244-253
    • /
    • 2005
  • In this paper, a performance evaluation model of the switch router with the multiple-buffered crossbar switches is proposed and examined. Buffered switch technique is well known to solve the data collision problem of the crossbar switch. The proposed evaluation model is developed by investigating the transfer patterns of data packets in a switch with output-buffers. The performance of the multiple-buffered crossbar switch is analyzed. Steady state probability concept is used to simplify the analyzing processes. Two important parameters of the network performance, throughput and delay, are then evaluated. To validate the proposed analysis model, the simulation is carried out on a network that uses the multiple buffered crossbar switches. Less than $2\%$ differences between analysis and simulation results are observed. It is also shown that the network performance is significantly improved when the small number of buffer spaces is given. However, the throughput elevation is getting reduced and network delay becomes increasing as more buffer spaces are added in a switch.

Performance Evaluation of a Multistage Interconnection Network with Output-Buffered ${\alpha}{\times}{\alpha}$ Switches (출력 버퍼형${\alpha}{\times}{\alpha}$스위치로 구성된 다단 연결망의 성능 분석)

  • 신태지;양명국
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.6
    • /
    • pp.738-748
    • /
    • 2002
  • In this paper, a performance evaluation model of the Multistage Interconnection Network(MIN) with the multiple-buffered crossbar switches is Proposed and examined. Buffered switch technique is well known to solve the data collision problem of the MIN. The proposed evaluation model is developed by investigating the transfer patterns of data packets in a switch with output-buffers. The performance of the multiple-buffered${\alpha}{\times}{\alpha}$ crossbar switch is analyzed. Steady state probability concept is used to simplify the analyzing processes, Two important parameters of the network performance, throughput and delay, are then evaluated, To validate the proposed analysis model, the simulation is carried out on a Baseline network that uses the multiple buffered crossbar switches. Less than 2% differences between analysis and simulation results are observed. It is also shown that the network performance is significantly improved when the small number of buffer spaces is given. However, the throughput elevation is getting reduced and network delay becomes increasing as more buffer spaces are added in a switch.