• Title/Summary/Keyword: 정상굴절

Search Result 72, Processing Time 0.033 seconds

The Study on Relation between Asthenopia of Lateral Phoria and Fusional Reserve (수평사위의 안정피로와 융합여력과의 관계)

  • Kim, Jung-Hee;Ryu, Kyung-Ho;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.329-335
    • /
    • 2006
  • The aim of this study was to evaluate the relation between Asthenopia of near lateral phoria and fusional reserve and also to provide fundamental clinical data. A total of 97 subjects, aged between 17 and 35 years old, who had no strabismus, an eye trouble or whole body disease, were examined nacked visual acuity, corrected visual acuity, corrected diopter, phoria, fusional reserve tests from October of 2005 to July of 2006. We excluded 8 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 87 subjects remained. The results were as follow. According to interview results was that in near works, exophoria and esophoria with asthenopia was 59.6%, 64.7%, and 52.6% respectively. The subjects who have exophoria of $0-6{\Delta}$ in the range of normal state was 19.1%. The subjects who have exophoria of $7{\Delta}$ over in the range of abnormal state was 80.9%. The fusional reserve was in inverse proportion to phoria. The fusional reserve was twice over of phoria were 30.3%, and twice under were 69.7%. The asthenopia complain persons were 33.9% with the twice over fusional reserve of phoria. The asthenopia no complain persons were 66.1% with the twice under fusional reserve of phoria. In conclusion, our research has shown conclusively that there is a link between asthenopia of lateral phoria and fusional reserve and we also find that fusional reserve must be examined when we prescribe for a patient who has phoria.

  • PDF

Central Corneal Thickness of Normal Eyes and Contact Lens-wearing Eyes Aged in their 20s and 30s (20․30대 정상안과 콘택트렌즈 착용안의 각막 중심 두께)

  • Park, Mijung;Park, Kyeong Sun;Ahn, So Yeoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.29-35
    • /
    • 2007
  • This study was conducted to measure the central corneal thickness(CTT) changes associated with kinds of wearing contact lens. The CCT was measured using ultrasonic pachymeter in three hundred four subjects in their 20s and 30s. Although the CCT of Group 1 who had never worn any kinds of contact lens had no differences between left and right eye as well as between genders, the CCT tended to become thinner depending on the increment in refractive error. In Group 2 wearing only soft contact lens, the CCT was thinner depending on wearing period, and subjects wearing for more than 10 years had significantly thin CCT comparing with subjects wearing for less than 4 years. There was no significant difference in the CCT between Group 3 wearing only RGP lens and Group 2 for less than 4 years. Furthermore, when comparing the CCT between the Group 2 and Group 4 changing to RGP lens after wearing soft contact lens, there was no statistically significant change in the CCT. However, the CCT was significantly thinner in Group 5 changing to soft contact lens after wearing PMMA(polymethyl methacrylate) hard lens compared with Group 2.

  • PDF

Analysis of anterior and posterior corneal spherical aberration with age in the korean (한국 성인의 연령에 따른 각막 전후면 구면수차에 관한 분석)

  • Song, Yun-Young;Jung, Mi-A;Kang, In-San;Choi, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.315-320
    • /
    • 2013
  • We have investigated the variation of spherical aberration of the anterior and posterior surface in a Korean sample population with various age between 20 to 71 years old. We used Pentacam (Oculus Inc., Germany) to measure the corneal radius, asphericity, and spherical aberration of 290 patients with normal cornea. There were negative correlation between corneal anterior radius and spherical aberration(r = -0.22, p<0.0001), and, there were negative correlation between corneal posterior radius and spherical aberration(r=-0.27, p < 0.0001). There were positive correlation between anterior asphericity and spherical aberration(r = 0.24, p < 0.0001), however there were negative correlation between posterior asphericity and spherical aberration(r = -0.17, p=0.00288).The average of anterior spherical aberration and posterior spherical aberration was $0.482{\pm}0.099{\mu}m$ and $-0.098{\pm}0.029{\mu}m$. The average of spherical aberration was $0.385{\pm}0.097{\mu}m$. There were significant positive correlations between anterior spherical aberration and age(r = 0.227, p<0.0001), and there were positive correlations between posterior aberration and age(r = 0.349, p<0.0001). It is considered that this data can be used as basic information for furture studies for improving the quality of vision of modern human and, through the analysis of the spherical aberration of cornea was to provide a better understanding of the optical part of the Korean's eye.

Evaluation and interpretation of the effects of heterogeneous layers in an OBS/air-gun crustal structure study (OBS/에어건을 이용한 지각구조 연구에서 불균질층의 영향에 대한 평가와 해석)

  • Tsuruga, Kayoko;Kasahara, Junzo;Kubota, Ryuji;Nishiyama, Eiichiro;Kamimura, Aya;Naito, Yoshihiro;Honda, Fuminori;Oikawa, Nobutaka;Tamura, Yasuo;Nishizawa, Azusa;Kaneda, Kentaro
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.1-14
    • /
    • 2008
  • We present a method for interpreting seismic records with arrivals and waveforms having characteristics which could be generated by extremely inhomogeneous velocity structures, such as non-typical oceanic crust, decollement at subduction zones, and seamounts in oceanic regions, by comparing them with synthetic waveforms. Recent extensive refraction and wide-angle reflection surveys in oceanic regions have provided us with a huge number of high-resolution and high-quality seismic records containing characteristic arrivals and waveforms, besides first arrivals and major reflected phases such as PmP. Some characteristic waveforms, with significant later reflected phases or anomalous amplitude decay with offset distance, are difficult to interpret using only a conventional interpretation method such as the traveltime tomographic inversion method. We find the best process for investigating such characteristic phases is to use an interactive interpretation method to compare observed data with synthetic waveforms, and calculate raypaths and traveltimes. This approach enables us to construct a reasonable structural model that includes all of the major characteristics of the observed waveforms. We present results here with some actual observed examples that might be of great help in the interpretation of such problematic phases. Our approach to the analysis of waveform characteristics is endorsed as an innovative method for constructing high-resolution and high-quality crustal structure models, not only in oceanic regions, but also in the continental regions.

Arthroscopic Treatment of Tibial Spine Fracture using Suture Hook and pull-out PDS (Suture Hook과 pull-out PDS를 이용한 경골극 골절의 관절경적 치료)

  • Lee, Young Kuk;Kim, Joon Seok;Sohn, Sung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.132-137
    • /
    • 1999
  • Displaced tibial spine fractures need the anatomical reduction of the displaced bone fragment to achieve normal range of motion and anterior stability of the knee joint. The purpose of this paper is to describe details of arthroscopic technique using suture hook and pull-out PDS and to evaluate the clinical results. We report 7 cases who underwent arthroscopic reduction and internal fixation using suture hook and pull-out PDS. All cases had fresh fractures generated within 3 weeks. The follow up period was at average 16.6 months. The fracture union was achieved at average 7.4 weeks. Knee exercise was started 2 weeks after the operation. One of the patients, who had combined injury of posterior cruciate ligament and lateral meniscus, showed limitation of knee movement. But he was underwent the arthroscopic fibrolysis at one year later, he returned to normal range of motion. Arthroscopic treatment of displaced tibial spine fracture using suture hook and pull-out PDS showed good results including rigid fixation and early mobilization. Therefore it is thought to be one of the effective operative techniques in treatment of the tibial spine fractures.

  • PDF

천연물로부터의 다당류에 의한 항종양효과에 관한 연구 I. 형광기표지와 HPLC에 의한 당의 분석

  • 김영식;박호군
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.132-132
    • /
    • 1993
  • 정상세포의 암세포로의 전환에 수반하는 세포표면상에 당구조 변화가 주목을 받고 있으며 이에 탄수화물이 세포간의 상호작용, 성장 등에 중요한 역할을 하리라고 생각된다. 따라서, 당구조 변화를 야기 시키는 당분해소효소나 전이활성 효소의 활성이 주요한 임상적 지표가 될 수 있다. 또한 천연물에서 유래된 다당류 등이 면역증강 효과를 나타내면서 항종양 효과를 보여준다. 이와같은 일을 원활히 수행하기 위해서는 당을 분석하는 기술이 필요하다. 당을 분석하는 방법으로 많이 이용된 것 중의 하나가 유도체를 만들어 GC에 의해서 확인하는 것이고 또한 당은 chromophore가 없기 때문에 굴절율의 검출기를 이용한 HPLC에 의해서도 분석이 가능하다. HPLC에 의한 또 다른 방법으로 당의 환원당 말단에 형광기를 결합시켜 감도를 매우 높게하여 역상 칼람을 이용해 당을 분리할 수 있다. 환원당에 결합시킬 수 있는 물질로는 대부분 amine기를 띄고 있고 결합하여 형광을 나타내는 특징을 지니고 있다. 본 연구는 형광기를 결합시켜 전기영동과 HPLC에 의해 동시에 추적이 가능한 물질을 결합시켜서 분석을 용이하게 한 방법을 이용하여 단당류를 $C_{18}$ column에 의해서 분리하였고 또한 모델로서 면역증강제로 사용되는 운지버섯 및 영지버섯 다당류와 생약에서 분리한 지유의 당을 분석하였다. 현재까지의 결과로 가장 좋은 방법은 $C_{18}$-->phenyl column을 연결하여 isocratic 방법으로 분리하였을 때이었다. 버섯의 당은 대부분이 glucose로 이루어졌고 지유는 arabinose가 주 구성성분이었다. 위의 분석 기술을 이용하면 피코몰 범위내에서 정확한 구조를 가진 항암효과의 올리고당 및 암세포의 발현에 따른 당단백질의 당의 구조를 규명하는데 도움을 줄 수 있다.aeonol이 aspirin과 같거나 강한 사망 억제 효과가 있었다.cyclopropyl-7-(2-furanyl) -6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 4), 1-cyclopropyl-7-(2-thiophenyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 6) ,1-cyclopropyl-7-(3-pyridinyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 8), 1-cyclopropyl-7-(2-fluoro-3-pyridinyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 10)를 합성하였다.10^{-7}$ M)에 의한 단백인산화에 대하여는 더 미약한 억제-효과를 나타내었다. 이상의 결과는 PDE-1과 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경우 Dv값이 제일 작았다. 바. 본 연구의 목적중의 하나인

  • PDF

Numerical Study of SPGD-based Phase Control of Coherent Beam Combining under Various Turbulent Atmospheric Conditions (대기외란에 따른 SPGD 기반 결맞음 빔결합 시스템 위상제어 동작성능 분석)

  • Kim, Hansol;Na, Jeongkyun;Jeong, Yoonchan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.247-258
    • /
    • 2020
  • In this paper, based on a stochastic parallel gradient descent (SPGD) algorithm we study phase control of a coherent-beam-combining system under turbulent atmospheric conditions. Based on the statistical theory of atmospheric turbulence, we carry out the analysis of the phase and wavefront distortion of a laser beam propagating through a turbulent atmospheric medium. We also conduct numerical simulations of a coherent-beam-combining system with 7- and 19-channel laser beams distorted by atmospheric turbulence. Through numerical simulations, we characterize the phase-control characteristics and efficiency of the coherent-beam-combining system under various degrees of atmospheric turbulence. It is verified that the SPGD algorithm is capable of realizing 7-channel coherent beam combining with a beam-combining efficiency of more than 90%, even under the turbulent atmospheric conditions up to cn2 of 10-13 m-2/3. In the case of 19-channel coherent beam combining, it is shown that the same turbulent atmospheric conditions result in a drastic reduction of the beam-combining efficiency down to 60%, due to the elevated impact of the corresponding refractive-index inhomogeneity. In addition, by putting together the number of iterations of the SPGD algorithm required for phase locking under atmospheric turbulence and the time intervals of atmospheric phenomena, which typically are of the order of ㎲, it is estimated that hundreds of MHz to a few GHz of computing bandwidth of SPGD-based phase control may be required for a coherent-beam-combining system to confront such turbulent atmospheric conditions. We expect the results of this paper to be useful for quantitatively analyzing and predicting the effects of atmospheric turbulence on the SPGD-based phase-control performance of a coherent-beam-combining system.

Estimation of the Convective Boundary Layer Height Using a UHF Radar (UHF 레이더를 이용한 대류 경계층 고도의 추정)

  • 허복행;김경익
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.1
    • /
    • pp.1-14
    • /
    • 2001
  • The enhancement of the refractive index structure parameter $C_n^2$ often occurs where vertical gradients of virtual potential temperature ${\theta}_v$ and mixing ratio q have their maximum values. The $C_n^2$ can be a very useful parameter for estimating the convective boundary layer(CBL) height. The behavior of $C_n^2$ peaks, often used to locate the height of mixed layer, was investigated in the present study. In addition, a new method to determine the CBL height objectively using both $C_n^2$ and vertical air velocity variance ${\sigma}_w$ data of UHF radar was also suggested. The present analysis showed that the $C_n^2$ peaks in the backscatter intensity profiles often occurred not only at the top of the CBL but also at the top of a residual layer or at a cloud layer. The $C_n^2$ peaks corresponding to the CBL heights were slightly lower than the CBL heights derived from rawinsonde sounding data when vertical mixing owing to weak solar heating was not significant and the height of strong vertical ${\theta}_v$ gradients were not consistent with that of strong vertical q gradients. However, the $C_n^2$ peaks corresponding to the CBL heights were in good agreement with the rawinsonde-estimated CBL hegiths when vertical mixing owing to solar heating was significant and the vertical gradient of both ${\theta}_v$ and q in the entrainment zone was very strong. The maximum backscatter intensity method, which determines the height of $C_n^2$ peak as the CBL height, correctly estimated the CBL height when the $C_n^2$ profile had single peak, but this method erroneously estimated the CBL height when there was a residual layer or a cloud layer over the top of the CBL. The new method distinguished when there the CBL height from the peak due a cloud layer or a residual layer using both $C_n^2$ and ${\sigma}_w$ data, and correctly estimated the CBL height. As for estimation of diurnal variation of the CBL height, the new method backscatter intensity method even if the vertical profile of backscatter intensity had two peaks from the CBL height and a residual layer or a cloud layer.

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.