• Title/Summary/Keyword: 정밀 저항

Search Result 464, Processing Time 0.035 seconds

Sewage Treatment Using Electric Field Pretreatment and Metal Membrane Microfiltration Process (전기장 전처리 및 금속 정밀여과 공정을 이용한 하수처리)

  • Jung, Jongtae;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.15-21
    • /
    • 2007
  • This study was investigated to evaluate the effect of electric fields application for the reduction of membrane fouling, the inactivation of microorganisms and the enhancement of particle coagulation in microfiltration/coagulation. Cumulative permeate in the case with electric field treatment showed high value compared to the case without electric field. Particularly, the increase of HRT (Hydraulic retention time) showed the increase of cumulative permeate as well as the decrease of total resistance. By electric field treatment, the amount of small particle size less than 100 ${\mu}m$ is increased and the survival fraction is reduced by the increase of electric field intensity. This may be attributed to the cleavage of particle or cytological destruction resulting from the inactivation of microorganism. Coagulant dosage of PAC compared with no electric field application could also be saved about 75% for the 95% of turbidity removal at 10 kV/cm.

  • PDF

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of Organic Materials in $N_2$-back-flushing (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척 시 유기물의 영향)

  • Park, Jin-Yong;Park, Gil-Yong
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • In this study, we used the hybrid module that was composed of granular activated carbons (GAC) packing between module inside and outside of tubular ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, modified solution was prepared with humic acid and kaolin. $N_2$-back-flushing of 10 sec was performed per every period of 10 min to minimize membrane fouling and to improve permeate flux (J). As a result, resistance of membrane fouling ($R_f$) decreased and J increased as concentration of humic acid changed from 10 mg/L to 2 mg/L step by step, and finally the highest total permeate volume ($V_T$) could be obtained at 2 mg/L. Then, treatment efficiencies of turbidity and $UV_{254}$ absorbance were excellent above 99.36% and 97.19%, respectively, but that of $UV_{254}$ absorbance for only microfiltration without GAC at 10 mg/L of humic acid was decreased a little as 90.84%.

Shallow Subsurface Structure of the Yaksoo Area, Ulsan, Korea by Geophysical Surveys (물리탐사기법에 의한 울산광역시 약수지역 천부지하구조 조사)

  • Lee, Jung-Mo;Kong, Young-Sae;Chang, Tae-Woo;Park, Dong-Hee;Kim, Tae-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2000
  • The location and geometry of the Ulsan Fault play important roles in interpreting tectonic evolution of the southeastern part of the Korean Peninsula. Dipole-dipole electrical resistivity surveys and seismic refraction surveys were carried out in the Yaksoo area, Ulsan in order to measure the thickness of the alluvium covering the Ulsan Fault and to find associated fracture zones and possibly the location of its major fault plane. The collected data were analyzed and interpreted. Some results reported previously by others were also used in this interpretation. No low resistivity anomalies were found in the cross-sectional resistivity image of the survey line located in the east of the Dong River. In contrast, well-developed continuous low resistivity anomalies were detected in the west of the Dong River. This strongly suggests that the major fault plane of the Ulsan Fault is located under or in the west part of the Dong River. Two refraction boundaries corresponding to the underground water level and the bottom of the alluvium were found by refraction surveys carried out on the limited part of the east survey line. The thickness of the alluvium was found to be about 30 m. Small faults in the basement rock identified by reflection surveys were not detected by both resistivity and refraction seismic surveys. This might be explained by assuming that low resistivity anomaly is more closely related to the clay contents than the water contents. On the other hand, it may be resulted by the limited resolution of the resistivity and refraction surveys. Detailed study is required to clarify the reason. Resistivity survey is frequently considered to be a good exploration method to detect subsurface faults. However, it appears to be less useful than reflection seismic survey in this work. In dipole-dipole resistivity survey, the number of separation should be increased to survey deeper subsurface with the same resolution. However, signal to noise ratio decreases as the number of separation increases. In this survey area, the signal to noise ratio of up to sixteen separations was good enough based on the statistical properties of measurements.

  • PDF

Hybrid Water Treatment of Photocatalyst Coated Polypropylene Beads and Ceramic Membranes: Effect of Membrane and Water Back-flushing Period (광촉매 코팅 폴리프로필렌 구와 세라믹 분리막의 혼성수처리: 분리막과 물 역세척 주기의 영향)

  • Park, Jin Yong;Hwang, Jung Hye
    • Membrane Journal
    • /
    • v.23 no.3
    • /
    • pp.211-219
    • /
    • 2013
  • Effect of water back-flushing period (FT) was investigated in hybrid water treatment process of carbon ultrafiltration and polypropylene (PP) beads coated with photocatalyst, and membrane effect was studied by comparing the previous studies with carbon microfiltration or alumina ultrafiltration, microfiltration membranes. FT 6 min was the most effective to control initial membrane fouling and optimal condition because the membrane fouling resistance was low until initial 60 min and the maximum total permeate volume was acquired at this FT. The turbidity treatment efficiency was high beyond 98.6%, and did not depend on FT, which was same with the previous result of carbon or alumina microfiltration. The organic matters treatment efficiency was the highest value of 98.2% at FT 6 min, which was almost same trend with the previous result of alumina microfiltration. Then the organic matters treatment efficiency of carbon microfiltration was the minimum at no back-flushing (NBF) and increased as decreasing FT, but that of alumina ultrafiltration was the maximum at NBF and also increased as decreasing FT. Therefore it means that water back-flushing effect on the organic matters treatment efficiency had a different mechanism depending on pore size in spite of the same material membranes.

Precise Orbit Determination of LEO Satellite Using Dual-Frequency GPS Data (이중 주파수 GPS 데이터를 이용한 저궤도 위성의 정밀궤도결정)

  • Hwang, Yoo-La;Lee, Byoung-Sun;Kim, Jae-Hoon;Yoon, Jae-Cheol
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.2
    • /
    • pp.229-236
    • /
    • 2009
  • KOorea Multi-purpose SATellite(KOMPSAT)-5 will be launched at 550km altitude in 2010. Accurate satellite position(20 cm) and velocity(0.03 cm/s) are required to treat highly precise Synthetic Aperture Radar(SAR) image processing. Ionosphere delay was eliminated using dual frequency GPS data and double differenced GPS measurement removed common clock errors of both GPS satellites and receiver. SAC-C carrier phase data with 0.1 Hz sampling rate was used to achieve precise orbit determination(POD) with ETRI GNSS Precise Orbit Determination(EGPOD) software, which was developed by ETRI. Dynamic model approach was used and satellite's position, velocity, and the coefficients of solar radiation pressure and drag were adjusted once per arc using Batch Least Square Estimator(BLSE) filter. Empirical accelerations for sinusoidal radial, along-track, and cross track terms were also estimated once per revolution for unmodeled dynamics. Additionally piece-wise constant acceleration for cross-track direction was estimated once per arc. The performance of POD was validated by comparing with JPL's Precise Orbit Ephemeris(POE).

Development of Polymer Elastic Bump Formation Process and Bump Deformation Behavior Analysis for Flexible Semiconductor Package Assembly (유연 반도체 패키지 접속을 위한 폴리머 탄성범프 범핑 공정 개발 및 범프 변형 거동 분석)

  • Lee, Jae Hak;Song, Jun-Yeob;Kim, Seung Man;Kim, Yong Jin;Park, Ah-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.31-43
    • /
    • 2019
  • In this study, polymer elastic bumps were fabricated for the flexible electronic package flip chip bonding and the viscoelastic and viscoplastic behavior of the polymer elastic bumps according to the temperature and load were analyzed using FEM and experiments. The polymer elastic bump is easy to deform by the bonding load, and it is confirmed that the bump height flatness problem is easily compensated and the stress concentration on thin chip is reduced remarkably. We also develop a spiral cap type and spoke cap type polymer elastic bump of $200{\mu}m$ diameter to complement Au metal cap crack phenomenon caused by excessive deformation of polymer elastic bump. The proposed polymer elastic bumps could reduce stress of metal wiring during bump deformation compared to metal cap bump, which is completely covered with metal wiring because the metal wiring on these bumps is partially patterned and easily deformable pattern. The spoke cap bump shows the lowest stress concentration in the metal wiring while maintaining the low contact resistance because the contact area between bump and pad was wider than that of the spiral cap bump.

Design of the Acupoint Discriminator(DM96A-2) by Improvement of Meridian Point Discrimination Parameter (경혈식별 파라메터의 개선에 의한 혈위식별시스템 DM96A-2의 설계)

  • 이후학;어윤기고수복정동명
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.825-828
    • /
    • 1998
  • 경혈을 대상으로 인체를 진단하는 의료기기들은 경혈점에 미세한 직류전류를 인가하고, 이 점에서의 전기저항과 세포의 분극에 의해 반응하는 경락체계의 균형상태를 측정하여 인체를 종합적으로 진단한다. 따라서 전 과정이 정확한 경혈의 위치에서 이루어져야만 치료효과와 진단의 신뢰성이 보장된다. 그러나 대부분의 경락관련 치료기들이 정확한 혈위식별에 어려움이 있고 사용자의 전문적 숙련을 요구한다. 따라서 선행연구에서 일정한 주파수로 교호되는 자극패턴(SPAC) 방식을 사용하여 식별률을 높인 혈위식별기 DM96A-1를 개발하였다. DM96A-1은 단일전원이 양방향으로 교호되는 전류로 자극펄스를 출력하고 측정범위가 0.5∼50㎂인 전류메터와 레벨메터를 이용하여 혈위의 전류량을 표시한다. 이에 따라 방향전환 소자의 두 채널 제어신호가 교호되는 과도기에서 두 자극패턴의 중첩 도통에 의해서 누설전류가 발생하는 경우가 있으며 이를 제거하기 위하여 정밀한 조정을 필요로 하는 불편이 있었다. 따라서 이와 같은 단점들을 보완하여 신뢰성 있는 출력 파라메터를 얻을 수 있도록 마이크로프로세서 i80c196kc를 사용하여 DM96A-2를 재 설계하였으며 임상실험에 의하여 개선된 최적 파라메터의 타당성을 검증하였다.

  • PDF

The wear properties of SiCw and SiCp reinforced bronze matrix composites (무윤활 미끄럼 마찰하에서의 SiC 휘스커 및 입자강화 청동기지 복합재의 마모특성)

  • 이상로;허무영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1993.04a
    • /
    • pp.59-62
    • /
    • 1993
  • 고품위의 동력전달 장치와 같은 고정밀 기능 부품들은 보다 높은 비강도, 고경도, 내마모성 및 내식성을 가져야 하며, 특히 소재의 마찰, 마모 특성은 기아제품 등의 수명, 정밀도 및 에너지 손실을 좌우하는 것으로서 물성의 열화를 극복할 수 있는 소재의 개발이 요구되고 있다. 지난 수년동안 금속기지에 $Al_2O_3$나 SiC등의 보강재를 첨가하여 복합재의 응착 및 연삭마모에 대한 저항성을 향상시키는 시도를 하고 있다. 주로 제조비용이 낮고 거의 등방적인 성질을 가지며 가공성이 좋은 입자 보강 복합재료에 대한 연구가 지배적이었지만, 입자 보강 복합재료의 경우 강도 및 탄성계수의 향상 정도가 적다는 단점을 지니고 있다. 본 연구에서는 분말야금법을 이용하여 금속기지에 세라믹상으로 SiC 입자 및 휘스커가 첨가된 복합재를 제조하여 제조공정변수에 따라 마모거동을 pin-on-disk 형태의 마모시험기에서 실험하였으며, 주사전자현미경으로 마모표면관찰 등으로 복합재의 마모기구를 연구하였다.

  • PDF

An Evaluation of Hydraulic Influence Caused by Tree Planting on Flood Plain through Field Survey (현장조사를 통한 고수부지 내 수목 식재의 수리적 영향 평가)

  • Kim, Chang-Wan;Cheong, Sang-Hwa;Lee, Min-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1264-1268
    • /
    • 2005
  • 본 연구에서는 2002년부터 2004년까지 3년에 걸쳐 한강고수부지(반포지구)에서 수목 식재에 따른 수리적 영향을 수치모형 및 현장조사를 통하여 평가하였다. RMA-2모형을 이용하여 분석한 결과 수목 식재전$\cdot$후로 수위는 3 cm 증가하고 유속은 4 cm/s 감소하는 것으로 나타났다. 따라서 식재로 인한 수리량의 변화는 매우 미미한 것으로 나타났다. .현장조사를 통해 얻은 실측자료도 홍수 시 수목 식재에 의한 하천수리특성에 미치는 영향은 크지 않은 것으로 나타났다. 그러나 매년 홍수기간 동안 보여 지는 침수양상에 따라 수리특성이 상이하게 나타났다. 그러므로 지속적인 자료 수집을 통하여 다양한 침수상황에 다른 기초 수리자료를 축척하고 정밀 분석할 필요가 있다. 또한 수리모형실험을 통해 현장조사 및 수치모형 결과와 비교$\cdot$분석하여 상호보완 할 필요성이 있다.

  • PDF

Development of a Charge&Discharge Test system for Super Capacitor (슈퍼커패시터 성능평가를 위한 충방전 시험 시스템 개발)

  • Kim, Geum-Soo;MOON, Jong-Hyun;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.494-495
    • /
    • 2011
  • 초고용량의 커패시터는 신재생 에너지 이용의 증가와 더불어 이용 영역이 점차 넓어지고 있어 유망신규시장의 창출이 기대된다. 따라서, 슈퍼커패시터의 성능을 측정하여 시험할 수 있는 충방전 순환 시험기가 필수적이라 할 수 있다. 이를 위해 슈퍼커패시터의 기본 충/방전 특성을 기준으로, 충전과 방전시의 고속계측이 가능하도록 용량 및 내부저항 측정을 위한 회로와 전압유지특성을 측정하기 위한 회로를 설계하였다. 5V, 100A Proto-type의 충방전 시험 시스템 구축으로 특성 평가결과, 전압 및 전류 측정 정밀도 ${\pm}$ 0.1%이내로 확인하였고, 데이터 모니터링 및 로깅을 위한 프로그램을 제작하였다. 또한 전체시스템 구성과 실험결과를 통해, 본 연구에서 개발하고자 하는 슈퍼커패시터용 충방전 시험 시스템이 실제 응용 가능함을 확인하였다.

  • PDF