• Title/Summary/Keyword: 정류장치

Search Result 206, Processing Time 0.04 seconds

A Study on the Dynamic Characteristics Improvement of Direct Drive Electro-mechanical Actuation System using Dynamic Force Feedback Control (동적 하중 되먹임 제어를 사용한 직구동 방식 전기기계식 구동장치시스템의 동특성 개선에 관한 연구)

  • Lee, Hee-Joong;Kang, E-Sok;Song, Ohseop
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.328-341
    • /
    • 2017
  • In the control actuator system of a launch vehicle based on thrust vectoring, the interaction between electro-mechanical position servo and inertial load are combined with the dynamic characteristics of the flexible vehicle support to generate synthetic resonance. This occurred resonance is fed back to the attitude control system and can influence stability of launch vehicle. In this study, we proposed a simulation model to analyze synthetic resonance of electro-mechanical actuation system for thrust vector control and explained the results of simulation and test using dynamic force feedback control which improves dynamic characteristics of servo actuation system by reducing synthetic resonance.

An improvement of cycloconverter output using phase shifting filter (상천이 필터를 이용한 싸이클로컨버터 출력의 개선)

  • Kim, Jong-Su;Seo, Dong-Hoan;Kim, Jeong-Woo;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Cycloconverter used as a power conversion device in the speed and torque control system of AC machines has the advantage of a simple control and a large torque at low speed. In addition, because a rectifier, a DC link, and an inverter are not installed, this system is simple and suitable for large power system. If a power conversion device, which is currently used as a propulsion motor of large vessel, is changed into cycloconverter, the system is simplified and then the installation costs can be significantly reduced. However, conventional cycloconverter has the increased harmonics because the power loss is large and the waveform of output voltage is distorted, due to the high-speed switching of power semiconductor devices. In order to improve these shortcomings, this paper describes a phase shifting filter which is composed of two inputs with different phases in the primary side and one output in the secondary one. As the voltage waveforms with two different phases are added and transformed into the secondary side, these outputs are close to sinusoidal waves. Thereby the voltage waveforms, which are applied to the propulsion motors, are improved and total harmonic distortions (THDs) are significantly reduced.

A Study on Stereo Visualization of the X-ray Scanned Image Based on Dual-line Sensors (듀얼센서 기반 X-선 검색영상 스테레오 가시화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2083-2090
    • /
    • 2010
  • This paper presents a 3-D visualization technique using stereo radioactive images to provide efficient inspection of fast moving cargo objects. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment. Stereo radioactive images are acquired from a specially designed equipment which consists of a X-ray source, linear radioactive sensors, and a moving stage. Two radioactive sensors are installed so that rectified stereo X-ray images of objects are acquired. Using the stereo X-ray images, we run a matching algorithm to find the correspondences between the images and reconstruct 3-D shapes of real objects. The objects are put in a parallelepiped box to simulate cargo inspection. Three real objects are tested and reconstructed. Due to the inherent ambiguity in the stereo X-ray images, we reconstruct 3-D shapes of the edges of the objects. The experimental results show the proposed technique can provide efficient visualization for cargo inspection.

Development of Portable Cardiopulmonary Support System (이동형 심폐보조시스템의 개발)

  • Lee, Hyuk-Soo;Min, Byoung-Goo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.94-99
    • /
    • 2007
  • Many cases of acute cardiac shock and cardiac arrest in emergency room and ICU have been increasing. In this case, ECMO with centrifugal pump has been used generally. However, due to the heavy weight and big size, the system is not adequate for emergency cases. And other defects of this system are that membrane oxygenator's pressure is high and blood are exposed to the air. There was some tries of ECMO using pulsatile pump, but it was found that the weak point of these system is high peak pressure and hemolysis. The mechanism of twin pulsatile pump is that Membrane oxygenator Outlet Pump(MOP) make negative pressure when Membrane oxygenator Inlet Pump(MIP) provides high positive pressure, and the negative pressure will decrease positive pressure of Membrane Oxygenator. Our group analyzed this advantage through In-Vitro and 12 Cases In-Vivo test.

Design of a AC driver with constant current and negative temperature resistance for a LED lamp (정전류와 부 열저항 특성을 갖는 AC Direct Driver를 이용한 LED 형광등 개발)

  • Kim, Hyun-jo;Son, Kyung-min;Kim, Min;Kim, Gwan-Hyung;Byun, Gi-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.382-384
    • /
    • 2013
  • LED is much brighter than the traditional incandescent, and low power consumption. Development and commercialization of LED fluorescent lamp is made in order to improve efficient fluorescent lamps with this existing and environmental problems. Because, unlike fluorescent lamps, it is not possible to directly use AC power to the unidirectional element having a polarity, LED requires a power supply. The power supply function is lowered as compared with the fluorescent lamp common in terms of maintenance costs because of the high price large. In this study, we constructed a circuit that can be controlled with a constant current in order to eliminate a phenomenon that brightness of the light which rectifies the AC power supply easy to place in the power supply due to the current change due to the voltage fluctuation is changed, in maintenance, I would like to propose how to develop a device which can be easily replaced less expensive composed of interchangeable modules of Plug in / out method to distinguish the LED module this.

  • PDF

Soft Switching Single Stage AC-DC Full Bridge Boost Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Single Stage AC-DC Full Bridge Boost 컨버터)

  • 김은수;조기연;김윤호;조용현;박경수;안호균;박순구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.377-383
    • /
    • 1999
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output i is presented in this paper. Due to the use of a non-dissipative snubber on the primary side, a single stage high-power f factor isolated full bridge boost converter has a significant reduction of switching losses in the main switching devices. The non-dissipative snubber adopted in this study consists of a snubber capacitor Cr, a snubber inductor Cr, a fast r recovery snubber diode Dr' and a commutation diode Dp. This paper presents the complete operating principles, t theoretical analysis and experimental results.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

The Construction of Solid State Detector System Using Commercially Available Diode and Its Application (정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구)

  • 신동오;홍성언;이병용;이명자
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

Topology of the Novel High Frequency Insulated Soft Switching PWM DC-DC Converter (새로운 고주파 절전형 소프트 스위칭 PWM DC-DC 컨버터의 토폴로지)

  • Kwon, Soon-Kurl;Suh, Ki-Young;Kim, Ju-Yong;Lee, Su-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.119-124
    • /
    • 2006
  • A novel high frequency insulated soft switching PWM DC-DC converter circuit is proposed and then it is achieved the high-efficiency. This converter does not use the o(citing current of a high frequency transformer but use inductance. Then it realizes a widely stable zero voltage switching operation with the use of a novel ON-OFF control method at synchronized rectification power MOSEFETs of the high frequency insulated transformer secondary. Therefore, it is brought over 97[%] measurement efficiency by proposed DC-DC converter.

WLED Communication System Using SC-FDMA Techniques (SC-FDMA기술을 적용한 WLED 통신시스템)

  • Li, Xun;Park, Noe-Yoon;Kim, Young-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.10
    • /
    • pp.94-101
    • /
    • 2010
  • In this paper, a WLED communication system with SC-FDMA technique is proposed. OFDM is a promising technique to realize high-speed WLED communication system. However, because of the PAPR, the system performance can be significantly compromised by non-linear distortions in the transmission chain. Furthermore, the overload current due to peak signal power lead the WLED equipment over bright which is harmful to equipment life and human‘s eye. The novel WLED communication system proposed in this paper solved these problems by using SC-FDMA technique which has an inherent low PAPR property. The severity of PAPR performances expressed by CCDF curve and the BER performances under different modulation schemes are analyzed in this paper.