• Title/Summary/Keyword: 정로

Search Result 54,988, Processing Time 0.085 seconds

Larvae Growth and Biochemical Composition Change of the Pacific Oyster Crassostra gigas, Larvae during Artificial Seed Production (참굴 Crassostrea gigas 인공종묘생산 시 유생의 성장과 체성분 변화)

  • Hur, Young-Baek;Min, Kwang-Sik;Kim, Tae-Eic;Lee, Seung-Ju;Hur, Sung-Bum
    • Journal of Aquaculture
    • /
    • v.21 no.4
    • /
    • pp.203-212
    • /
    • 2008
  • A nutritional demand of oyster, Crassostrea gigas larva as part of research for improving of utilization of microalgae being used for the artificial oyster seed production. The change of body growth and biochemical compositions of larvae were investigated during larvae rearing in hatchery. The larvae were cultured in 60 M/T tank and fed mixture 6 different phytoplankton species, Isochrysis galbana (30%), Cheatoceros gracilis (20%), Pavlova lutheri (20%), Phaeodactylum triconutum (10%), Nannochryis oculata (10%) and Tetraselmis tetrathele (10%). The initial feeding amount was $0.3{\times}10^4cells/mL$ at three times a day to D-shaped larva and the feeding amount had been increased 30% gradually every two day since the larvae were raising. The larvae were developed from D shape to pediveliger stage for 12 days. The daily growth of shell length and hight were $5.8{\sim}30.8\;{\mu}m$ and $8.7{\sim}31.4\;{\mu}m$, respectively and weight gains were changed from D shape to pediveliger as follow: wet weight was $0.52{\sim}15.0\;{\mu}g/larva$, dry weight was $0.2{\sim}6.5\;{\mu}g/larva$, and ash free dry weight was $0.1{\sim}8.5\;{\mu}g/larva$. The larvae growth pattern shown a logarithmic phase from D shape to umbone stage but after that stage shown a exponential growth aspect. The crude protein, crude lipid and nitrogen free extract (NFE) of larvae during rearing periods were analyzed as $6.1{\sim}10.6%$, $0.6{\sim}1.1%$ and 1.0-2.7%, respectively. And the total amino acid contents of the larvae during rearing periods were in order as glutamic acid $1.26{\sim}2.24%$, aspartic acid $0.97{\sim}1.70%$, and methionine $0.12{\sim}0.33%$. Of the total fatty acid in the analyzed larvae, the saturated fatty acid (SSAFA) was decreased from 54.3% (D shaped larvae) to 17.1 % (pediveliger) as larvae development but the total mono-unsaturated fatty acid (${\Sigma}MOFA$) and Poly-unsaturated fatty acid (${\Sigma}PUFA$) were increased from 29.9% and 7.8% to 40.6% and 45.6%, respectively. By the way the each fatty acid of the larvae were composed of palmitic acid $9.89{\sim}36.95%$, oleic acid $12.17{\sim}32.29%$, linoleic acid $1.96{\sim}33.55%$, EPA $2.17{\sim}11.58%$ and DHA $1.95{\sim}4.51%$. As a result of this study, the larvae of oyster were demanded a various nutrients for healthy growth and the feeding control, expecially after umbone stage larvae are a rapidly growing time, is very important for success of artificial seed production.

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

The Effect of Seminal Plasma on Chilling and Freezing of Canine Spermatozoa (개 정액의 정장이 개정자의 냉각과 동결에 미치는 영향)

  • You, Myung-Jo;Lee, John-Hwa;Kim, In-Shik;Park, Jin-Ho;Kwon, Jung-Kee;Kim, Jong-Hoon;Kim, Bum-Seok;Yu, Il-Jeoung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.486-492
    • /
    • 2007
  • Seminal plasma(SP) is usually removed from semen that is to be cryopreserved. However, some reports indicate that SP has beneficial effects on spermatozoa during chilling and freezing. The purpose of this study was to determine the effect of SP on sperm survival by adding SP to the extender before cooling and freezing canine spermatozoa. In replicate experiments, ejaculates obtained from four healthy dogs(1-4 years old) of various breeds were pooled, centrifuged at $300{\times}g$ for 10 min at $25^{\circ}C$, and the supernatant of seminal plasma was decanted. Spermatozoa were suspended in egg yolk-Tris(EYT) buffer. The study comprised two experiments: [Exp 1] Sperm were suspended in EYT extender containing either 0, 20, 40, 80 or 100% SP and were slowly cooled to $4^{\circ}C$ for 2h or held at $25^{\circ}C$ as controls. Sperm concentration was adjusted to $2{\times}10^8/ml$. [Exp II] Sperm samples, each of which contained $1{\times}10^8/ml$, were assigned to nine groups to be frozen. In the first four groups, sperm in EYT containing either 20, 40, 80 or 100% SP were cooled to $4^{\circ}C$, then diluted to contain final concentrations of EYT+0.6M glycerol and then were frozen. The final concentrations of SP were 10, 20, 40 or 50%. In the other four groups, sperm in EYT alone were first cooled slowly to $4^{\circ}C$, then diluted to contain final concentrations of EYT+0.6M glycerol plus 10, 20, 40 or 50% SP and then were frozen. Spermatozoa, which chilled in EYT alone and diluted to contain final concentrations of EYT+0.6M glycerol without seminal plasma, and then frozen, was regarded as control. Spermatozoa were frozen at $25^{\circ}C/min$ of cooling rate in plastic straws that were suspended above liquid nitrogen and thawed in water at $38^{\circ}C$ for 1 min. Sperm survival was assayed by determining progressive motility and integrity of plasma and acrosome membranes. Progressive motility was determined by microscopic examination at $200{\times}$ magnification. Membrane integrity was assessed by use of a double fluorescent dye, and acrosome integrity by staining sperm with Pisum sativum agglutinin. The results of the first experiment showed that adding SP did not improve motility of spermatozoa compared to those incubated without SP regardless of temperature. The results of the second experiment showed that spermatozoa suspended in EYT+0.6M glycerol containing SP exhibited the higher progressive motility before being frozen(P<0.05). However, frozen-thawed spermatozoa that had suspended in EYT+0.6M glycerol containing SP showed the similar or lower viability(P<0.05). In summary, although seminal plasma did not affect spermatozoa that were chilled in EYT without cryoprotectant(CPA), addition of seminal plasma to EYT containing CPA did significantly improved progressive motility of canine spermatozoa that were chilled.

Crystal Structures of $Cd_6-A$ Dehydrated at $750^{\circ}C$ and Dehydrated $Cd_6-A$ Reacted with Cs Vapor ($750^{\circ}C$ 에서 탈수한 $Cd_6-A$의 결정구조와 이 결정을 세슘 증기로 반응시킨 결정구조)

  • Se Bok Jang;Yang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.2
    • /
    • pp.191-198
    • /
    • 1993
  • The crystal structures of $Cd_{6-}A$ evacuated at $2{\times}10^{-6}$ torr and $750^{\circ}C$ (a = 12.204(1) $\AA$) and dehydrated $Cd_{6-}A$ reacted with 0.1 torr of Cs vapor at $250^{\circ}C$ for 12 hours (a = 12.279(1) $\AA$) have been determined by single crystal X-ray diffraction techniques in the cubic space group Pm3m at $21(1)^{\circ}C.$ Their structures were refined to final error indices, $R_1=$ 0.081 and $R_2=$ 0.091 with 151 reflections and $R_1=$ 0.095 and $R_2=$ 0.089 with 82 reflections, respectively, for which I > $3\sigma(I).$ In vacuum dehydrated $Cd_{6-}A$, six $Cd^{2+}$ ions occupy threefold-axis positions near 6-ring, recessed 0.460(3) $\AA$ into the sodalite cavity from the (111) plane at O(3) : Cd-O(3) = 2.18(2) $\AA$ and O(3)-Cd-O(3) = $115.7(4)^{\circ}.$ Upon treating it with 0.1 torr of Cs vapor at $250^{\circ}C$, all 6 $Cd^{2+}$ ions in dehydrated $Cd_{6-}A$ are reduced by Cs vapor and Cs species are found at 4 crystallographic sites : 3.0 $Cs^+$ ions lie at the centers of the 8-rings at sites of $D_{4h}$ symmetry; ca. 9.0 Cs+ ions lie on the threefold axes of unit cell, ca. 7 in the large cavity and ca. 2 in the sodalite cavity; ca. 0.5 $Cs^+$ ion is found near a 4-ring. In this structure, ca. 12.5 Cs species are found per unit cell, more than the twelve $Cs^+$ ions needed to balance the anionic charge of zeolite framework, indicating that sorption of Cs0 has occurred. The occupancies observed are simply explained by two unit cell arrangements, $Cs_{12}-A$ and $Cs_{13}-A$. About 50% of unit cells may have two $Cs^+$ ions in sodalite unit near opposite 6-rings, six in the large cavity near 6-ring and one in the large cavity near a 4-ring. The remaining 50% of unit cells may have two Cs species in the sodalite unit which are closely associated with two out of 8 $Cs^+$ ions in the large cavity to form linear $(Cs_4)^{3+}$ clusters. These clusters lie on threefold axes and extend through the centers of sodalite units. In all unit cells, three $Cs^+$ ions fill equipoints of symmetry $D_{4h}$ at the centers of 8-rings.

  • PDF

Comparison of Electrocardiographic Time Intervals, Amplitudes and Vectors in 7 Different Athletic Groups (운동종목별(運動種目別) 선수(選手)의 심전도시간간격(心電圖時間間隔), 파고(波高) 및 벡터의 비교(比較))

  • Kwon, Ki-Young;Lee, Won-Jung;Hwang, Soo-Kwan;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.61-72
    • /
    • 1985
  • In order to compare the cardiac function of various groups of athletes, the resting electrocardiographic time intervals, amplitudes and vectors were analyzed in high school athletes of throwing(n=7), jumping(n=11), short track(n=8), long track(n=14), boxing(n=7), volleyball(n=8) and baseball(n=9), and nonathletic control students(n= 19). All athletic groups showed a significantly longer R-R interval(0.96-1.09 sec) than the controls (0.78 sec). Therefore, the heart rate was significantly slower in atheletes than in the control, but was not different among the different athletic groups. R-R interval is the sum of intervals of P-R, 0-T and T-P: P-R and Q-T intervals showed no difference among the control and athletic groups, but T-P interval in the jump, short track, long track and boxing groups was significantly higher than the control. R-B interval showed a significant correlation with T-P or Q-T intervals but no correlation with P-R or QRS complex. Comparing the amplitude of electrocardiographic waves, the athletic groups showed a lower trend in P wave than the controls. T wave in lead $V_5\;(Tv_5)$ was similar in the athletic and control groups. The long track group showed a significantly higher waves of $Rv_5$, $Sv_1$, and the sum of $Rv_5$ and $Sv_1$ than not only the controls but also the other athletic group. The angles of P, QRS, and T vector in the frontal and horizontal planes were not different among the control and all the athletic groups. Each athletic group stowed a lower trend in amplitude of P vector in the frontal plane, but in horizontal plane, throwing, jump, short track and baseball groups showed a significantly lower than the controls. The amplitude of QRS and T vector was similar in the athletic and control groups, but only the baseball group showed a significantly higher QRS vector in the frontal plane. In taken together, all the athletic groups showed a slower heart rate than the controls, mainly because of elongated T-P interval. Comparing the electrocardiographic waves and vector, the athletic groups showed lower amplitudes of P wave and P vector than the controls. Values of $Rv_5$ and $Sv_1$ strongly suggest that only the long distance runners among the various athletic groups developed a left ventricular hypertrophy.

  • PDF

End to End Model and Delay Performance for V2X in 5G (5G에서 V2X를 위한 End to End 모델 및 지연 성능 평가)

  • Bae, Kyoung Yul;Lee, Hong Woo
    • Journal of Intelligence and Information Systems
    • /
    • v.22 no.1
    • /
    • pp.107-118
    • /
    • 2016
  • The advent of 5G mobile communications, which is expected in 2020, will provide many services such as Internet of Things (IoT) and vehicle-to-infra/vehicle/nomadic (V2X) communication. There are many requirements to realizing these services: reduced latency, high data rate and reliability, and real-time service. In particular, a high level of reliability and delay sensitivity with an increased data rate are very important for M2M, IoT, and Factory 4.0. Around the world, 5G standardization organizations have considered these services and grouped them to finally derive the technical requirements and service scenarios. The first scenario is broadcast services that use a high data rate for multiple cases of sporting events or emergencies. The second scenario is as support for e-Health, car reliability, etc.; the third scenario is related to VR games with delay sensitivity and real-time techniques. Recently, these groups have been forming agreements on the requirements for such scenarios and the target level. Various techniques are being studied to satisfy such requirements and are being discussed in the context of software-defined networking (SDN) as the next-generation network architecture. SDN is being used to standardize ONF and basically refers to a structure that separates signals for the control plane from the packets for the data plane. One of the best examples for low latency and high reliability is an intelligent traffic system (ITS) using V2X. Because a car passes a small cell of the 5G network very rapidly, the messages to be delivered in the event of an emergency have to be transported in a very short time. This is a typical example requiring high delay sensitivity. 5G has to support a high reliability and delay sensitivity requirements for V2X in the field of traffic control. For these reasons, V2X is a major application of critical delay. V2X (vehicle-to-infra/vehicle/nomadic) represents all types of communication methods applicable to road and vehicles. It refers to a connected or networked vehicle. V2X can be divided into three kinds of communications. First is the communication between a vehicle and infrastructure (vehicle-to-infrastructure; V2I). Second is the communication between a vehicle and another vehicle (vehicle-to-vehicle; V2V). Third is the communication between a vehicle and mobile equipment (vehicle-to-nomadic devices; V2N). This will be added in the future in various fields. Because the SDN structure is under consideration as the next-generation network architecture, the SDN architecture is significant. However, the centralized architecture of SDN can be considered as an unfavorable structure for delay-sensitive services because a centralized architecture is needed to communicate with many nodes and provide processing power. Therefore, in the case of emergency V2X communications, delay-related control functions require a tree supporting structure. For such a scenario, the architecture of the network processing the vehicle information is a major variable affecting delay. Because it is difficult to meet the desired level of delay sensitivity with a typical fully centralized SDN structure, research on the optimal size of an SDN for processing information is needed. This study examined the SDN architecture considering the V2X emergency delay requirements of a 5G network in the worst-case scenario and performed a system-level simulation on the speed of the car, radius, and cell tier to derive a range of cells for information transfer in SDN network. In the simulation, because 5G provides a sufficiently high data rate, the information for neighboring vehicle support to the car was assumed to be without errors. Furthermore, the 5G small cell was assumed to have a cell radius of 50-100 m, and the maximum speed of the vehicle was considered to be 30-200 km/h in order to examine the network architecture to minimize the delay.

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Comparative Study on the Actual Conditions about Hypertension and Diabetes Case Management of the Elderly at the Hall for the Aged and the D Senior's College (D 노인대학과 경로당 노인들의 건강행태 및 고혈압당뇨병 관리실태 비교조사)

  • Yoon, Young-Suk;Kwon, Yang-Ok;Jung, Young-Hee
    • Journal of dental hygiene science
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • The purpose of this study was to provide the basic data for effective intervention of oral health behaviors strategy and to compare the actual conditions about hypertension and diabetes case management of the elderly at the hall for the aged and the D senior's college. The research method was a questionnaire including hypertension and diabetes case management of the elderly and the subjects were 174 of the elderly(65 age over) at the hall for the aged(100) and the senior's college(74). The results of this study were as follows; 1. Hypertension 1)The incidence of hypertension of elderly at the hall for the aged and the senior's college were 32.2%. 2)83.9% of the hypertension cases were initially diagnosed during hospital examination(p < 0.05). 3)Regular blood pressure checks were performed more than one time monthly on 76.8% of the cases(p < 0.05). 4)Blood pressure control was well controlled on 75%(p < 0.05). 5)85.7% of the elderly at the hall for the aged took hypertension drugs daily and 42.9% of the elderly at the senior's college took no drug alternatively(p < 0.05). 2. Diabetes 1)The incidence of the diabetes of elderly at the hall for the aged and the senior's college were 14.4%. 2)80.0% of the diabetes cases were initially diagnosed during hospital examination(p < 0.05). 3)64.0% of the cases did not have blood sugar measuring instrument(p < 0.05). 4. In the quality of life, the thinking of no difficulty in walking and no anxiety/depression was more presented on the elderly at the senior's college than those at the hall for the aged(p < 0.05). 5. The subjective health condition scores were higher on the elderly at the senior's college than those at the hall for the aged(p < 0.05).

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.