• Title/Summary/Keyword: 정량적 초음파 측정

Search Result 109, Processing Time 0.026 seconds

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I) (전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I))

  • Kang, Young-June;Park, Nak-Kyu;Ryu, Won-Jae;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.393-401
    • /
    • 2002
  • Pipelines in power plants, nuclear facilities and chemical industries are often affected by corrosion effects. It is important to inspect the internal defects in pipelines in oder to guarantee safe operational condition. We have taken relatively much time, cost and manpower to use conventional NDT methods because these methods are contact measuring methods. In this paper, we used digital shearography, a laser-based optical method which allows full-field measurement of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time measurement. The experiment was performed with pressure vessels which has different internal cracks and detected internal cracks in the pressure vessels at a real time using phase shifting method.

Measurement of Mechanical Property and Thermal Expansion Coefficient of Carbon-Nanotube-Reinforced Epoxy Composites (탄소나노튜브로 강화된 에폭시 복합재료의 기계적 물성과 열팽창 계수 측정)

  • Ku, Min Ye;Kim, Jung Hyun;Kang, Hee Yong;Lee, Gyo Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.657-664
    • /
    • 2013
  • By using shear mixing and ultrasonication, we fabricated specimens of well-dispersed multi-walled carbon nanotube composites. To confirm the proper dispersion of the filler, we used scanning electron microscopy images for quantitative evaluation and a tensile test for qualitative assessment. Furthermore, the coefficients of thermal expansion of several specimens having different filler contents were calculated from the measured thermal strains and temperatures of the specimens. Based on the microscopy images of the well-dispersed fillers and the small deviations in the measurements of the tensile strength and stiffness, we confirmed the proper dispersion of nanotubes in the epoxy. As the filler contents were increased, the values of tensile strength increased from 58.33 to 68.81 MPa, and those of stiffness increased from 2.93 to 3.27 GPa. At the same time, the coefficients of thermal expansion decreased. This implies better thermal stability of the specimen.

Application of Non-linear Acoustic Effect for Evaluation of Degradation of 2.25Cr-1Mo Steel (2.25Cr-1Mo 강의 열화도 평가를 위한 비선형 음향효과 응용법)

  • Choi, Y.H.;Jhang, K.Y.;Park, I.K.;Kim, H.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.170-176
    • /
    • 2002
  • Nonlinear acoustic effect has been considered as an effective tool for the evaluation of material degradation. In this paper, the applicability of nonlinear acoustic effect to the evaluation of degraded 2.25Cr-1Mo steel is investigated. Firstly, artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540^{\circ}C$. Secondly, ultrasonic nonlinear parameter was quantitatively measured by bi-spectrum and power spectrum. Nonlinear acoustic parameter from bi-spectrum was found to be clearly sensitive to the aging time.

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

The Usefulness of Liver Fibroscan Test Using Ultrasound Image (초음파영상을 이용한 간탄력도 검사의 유용성)

  • An, Hyun;Lee, Jin-Soo;Im, In-Chul;Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.205-212
    • /
    • 2017
  • Chronic diffuse hepatopathy is one of the important clinical tasks to reduce mortality and morbidity due to liver cirrhosis, liver failure, and liver cancer. The purpose of this study was to evaluate the criteria for predicting liver and chronic liver disease using Fibroscan based on ultrasound diagnosis. Serum and liver stiffness measurement(kPa) were analyzed in 280 patients and cut-off values of liver stiffness measurement for predicting fatty liver and chronic diffuse hepatopathy were determined using ROC curve analysis. Bilirubin and PT(prothrombin time) were not related to disease prediction(p=0.243, p=0.115). Serum glucose and triglyceride levels were significantly higher in the liver (p<0.05). The cut-off value for predicting chronic diffuse hepatopathy was determined as 10.3 kPa(AUC 0.98, sensitivity 94.94%, specificity 94.93%) in the order of control group, fatty liver and chronic diffuse hepatopathy. Therefore, it will be used as a primary tool for the diagnosis of chronic liver disease patients with quantitative evaluation.

Dependencies of Group Velocity and Attenuation Coefficient on Structural Properties in Copper and Nickel Foams with an Open-Celled Structure as Trabecular-Bone-Mimicking Phantoms (해면질골 팬텀으로서 개포된 구조를 갖는 구리폼 및 니켈폼에서 구조적 특성에 대한 군속도 및 감쇠계수의 의존성)

  • Kim, Seong-Il;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.158-166
    • /
    • 2011
  • In the present study, copper and nickel foams with an open-celled structure as trabecular-bone-mimicking phantoms were used to investigate the dependencies of group velocity and attenuation coefficient on structural properties such as trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) in trabecular bone. The group velocity and attenuation coefficient of the copper and nickel foams were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. The separation of the Biot's fast and slow waves was consistently observed in the ultrasonic signals transmitted through the copper and nickel foams. The group velocities of the copper and nickel foams showed highly positive correlations with Tb.Th and Tb.Sp. The attenuation coefficient of the copper foam showed a highly negative correlation with Tb.Th and Tb.Sp, whereas that of the nickle foam showed a highly positive correlation with Tb.Th and Tb.Sp. These results advance our understanding of those previously reported by other researchers using trabecular bone samples or phantoms.

Quantification of Heterogenous Background Fractures in Bedrocks of Gyeongju LILW Disposal Site (경주 방폐장의 불균질 배경 단열의 정량화)

  • Cho, Hyunjin;Cheong, Jae-Yeol;Lim, Doo-hyun;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.463-474
    • /
    • 2017
  • Heterogeneous background fractures of granite and sedimentary rocks in Gyeongju LILW (low-intermediate level radioactive waste) facility area have been characterized quantitatively by analyzing fracture parameters (orientation, intensity, and size). Surface geological survey, electrical resistivity survey, and acoustic televiewer log data were used to characterize the heterogeneity of background fractures. Bootstrap method was applied to represent spatial anisotropy of variably oriented background fractures in the study area. As a result, the fracture intensity was correlated to the inverse distance from the faults weighted by nearest fault size and the mean value of electrical resistivity and the average volumetric fracture intensity ($P_{32}$) was estimated as $3.1m^2/m^3$. Size (or equivalent radius) of the background fractures ranged from 1.5 m to 86 m and followed to power-law distribution based on the fractal property of fracture size, using fractures measured on underground silos and identified surface faults.

Effect of Specimen Geometry on Bending and Tensile Strength of Material Used in Dissimilar Joints (이종 접합재의 굽힘 및 인장강도에 미치는 시험편 형상의 효과)

  • Hur, Jang-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.341-346
    • /
    • 2010
  • The effect of specimen geometry on the bending and tensile strengths of dissimilar joints ($\beta-Si_3N_4/S45C$) with copper interlayers was evaluated. The average bending strength of specimens with circular cross sections was higher than that of specimens with rectangular cross sections. The crack initiation stress ($\sigma_i$) was successfully determined by the acoustic emission (AE) method and was approximately 60~80% of the bending strength. The residual stresses near the interfaces on the ceramic side were measured by X-ray diffraction before conducting the bending test. The bending strength and the crack initiation stress decreased with an increase in the residual stresses. The effect of the bending strain component was evaluated by the tensile testing; the tensile strength decreased with an increase in the bending strain component and was approximately 80% of the bending strength.

PD Characteristics Analysis of Improved Insulating Materials for Power Cables (개질된 전력용 케이블절연체의 부분방전 특성 해석)

  • 송일근;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.93-102
    • /
    • 1997
  • In order tl get Maaterial requirements for the Improviment of erliability of Insulatint materials for power cables, partial discharge characteristics of Polyethylenes were measured by an ultrasonic techjique and Measured signals were processed to cbtain the paraceters useful for thr quantification of partial discharge characteristics of polyethylenes. This technique was applied to obtain material requirements for the development of improved insulating materials for power cables,As a result, it was found that partial discharging activities in polyethylenes were suppressed considerably when p proper amount of acrylic acid, 0.003[wt %]in this particular case, is grafted on polyethylene chains.It can be concludid from the present study that partial discharging actibities in polyethylenes could be suppressed by the modification of polyethylene with proper chemical components, acrilic acid in this particular study.

  • PDF