• Title/Summary/Keyword: 접합 면적

Search Result 149, Processing Time 0.025 seconds

Junction Capacitance Dependence of Response Time for Magnetic Tunnel Junction (터널링 자기저항 소자의 접합면 정전용량에 따른 전기적 응답특성)

  • Park, S.Y.;Choi, Y.B.;Jo, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • In this research, the effects of capacitance to the access time were studied at the junction area of tunneling magnetoresistance when these were used as memory devices. These results were obtained by applying electric signal input and magnetic field was not used. We applied bipolar square waves of 1MHz to the MTJ samples to obtain the results and time constant ($\tau$) calculated by observing wave responses utilizing an oscilloscope. And time constant was compared with junction area. Each part of MTJ sample, such as electrical pad, lead and contact area, was modeled as an electrical equivalent circuit based on experimental results. For the 200㎛$\times$200㎛ cell, junction capacitance was 90 pF. Also, measurement and simulation results were compared, which showed those similarity.

Structural Behavior of Beam-to-Column Connections of Rectangular CFT Structures having Different Diaphragm Opening (콘크리트충전 각형강관구조의 다이아프램 개구부 형상에 따른 기둥-보 접합부 구조적 거동)

  • Kim, Ki Hoon;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.289-298
    • /
    • 2015
  • The steel tube of Concrete-Filled Tube(CFT) confines the concrete and the concrete restrains the buckling of the tube, The objective of this study is to investigate the influences of the opening shape of the through diaphragm in case of the rectangular CFT column-to-beam connection through the structural experiment. The experiment results are compared with analysis results obtained by using the FEM program. These results are shown that strength of the rectangular CFT column-to-beam connection have similar structural performance regardless of the opening shape if opening areas of the through diaphragm are same. Also in case the connection area/shape of the through diaphragm and the flange of H-beam are similar, it was ascertained that the bending stress occurred at the beam can be transferred to the column through the diaphragm.

Efficiency Improvement of $N^+NPP^+$ Si Solar Cell with High Low Junction Emitter Structure (고저 접합 에미터 구조를 갖는 $N^+NPP^+$ Si 태양전지의 효율 개선)

  • 장지근;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.1
    • /
    • pp.62-70
    • /
    • 1984
  • N+NPP+ HLEBSF (high low emitter back surface field) solar cells which have N+N high low junction in the emitter as well as N+PP+ BSF cells were designed and fabricated by using <111> oriented P type Si wafers with the resistivity of 10$\Omega$/$\textrm{cm}^2$ and the thickness of 13-15 mil. Physical parameters (impurity concentration, thickness) at each region of N+PP+ and N+NPP+ cell were made equally through same masks and simultaneous process except N region of HLEBSF cell to investigate the high low emitter junction effect for efficiency improvement. Under the light intensity of 100 mW/$\textrm{cm}^2$, total area (active area) conversion efficiency were typically 10.94% (12.16%) for N+PP+ BSF cells and 12.07% (13.41%) for N+N PP+ cells. Efficiency improvement of N+NPP+ cell which has high low emitter Junction structure is resulted from the suppression of emitter recombination current and the increasement of open circuit voltage (Voc) and short circuit current (Ish) by removing heavy doping effects occurring in N+ emitter region.

  • PDF

Assessment of Optimum Reinforcement of Rebar for Joint of PHC Pile and Foundation Plate (고강도 콘크리트 말뚝과 기초판 접합부의 최적 철근보강량 산정)

  • Park, Jong-Bae;Sim, Young-Jong;Chun, Young-Soo;Park, Seong-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.

Study on the Characteristics of GaInP/AlGaInP Heterojunction Photovoltaic Cells under Concentrated Illumination (집광 조건에서의 GaInP/AlGaInP 이종접합 구조 태양전지 특성 연구)

  • Kim, Junghwan
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.504-508
    • /
    • 2019
  • The feasibility of replacing the tope cell of pn GaInP homojunction with our GaInP/AlGaInP heterojunction structure in III-V semiconductor multijunction photovoltaic (MJPV) cells having the highest current conversion efficiency was investigated. The performance of photovoltaic (PV) cells grown on $2^{\circ}$ and $10^{\circ}$ off-oriented GaAs substrates were compared to each other. The PV cells on the $10^{\circ}$ off-cut substrate showed higher short-circuit current density ($J_{sc}$) and conversion efficiency values than that of using the $2^{\circ}$ one. For $2{\times}2mm^2$ area PV cell on $10^{\circ}$ off substrate, the $J_{sc}$ of $9.21mA/cm^2$ and the open-circuit voltage of 1.38 V were measured under 1 sun illumination. For $5{\times}5mm^2$ cell on $10^{\circ}$ off substrate, the conversion efficiency was decreased from 6.03% (1 sun) to 5.28% (20 sun) due to a decrease in fiill factor (FF).

Evaluation of Moment Transfer Efficiency According to the Connection Length of the Column Flange and the Beam Web of the H-beam Column Connection (H형강 보-기둥 접합부의 보 웨브 단부접합길이에 따른 모멘트전달효율 평가)

  • Hong, Young-Ju;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.193-203
    • /
    • 2022
  • In this study, in order to compare the seismic performance of steel structure beam-column connection details and non-scallop connection details mainly used in Korea, a full-scale static cyclic loading test and FEM analysis were conducted through the same modeling as the experiment. For quantitative numerical comparison, the strain concentration ratio and moment transfer efficiency used in previous studies were cited. As the welding area of the beam web decreased, the deformation rate of the beam flange increased, and the plastic deformation capacity according to the rotation angle decreased or brittle fracture occurred. Comparing the analysis results with the experimental results, the possibility of brittle fracture tended to increase when the web welding ratio for the total cross-sectional area of H-shaped fell below 60%.

Fabrication of large scale $Cu_2$S/CdS solar cells prepared by spray pyrolysis (Spray pyrolysis 방법에 의한 넓은 면적의 $Cu_2$S/CdS 태양전지의 제작)

  • 차덕준;고정곤;정상조;남승재;김광윤;전용기
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.341-347
    • /
    • 1996
  • We fabricated the effective $Cu_2S$/CdS solar cells with large area by a spray pyrolysis method. In preparation process, we investigated the process parameters which directly influenced the efficiency of solar cell, such as the grid contact for electrodes, the temperature condition of CdS spray and the junction characteristics of $Cu_2S$ layer, by scanning electron microscope(SEM), x-ray diffraction(XRD) and temperature dependent optical absorption and photoconductivity. The $Cu_2S$/CdS solar cell with area of 1$\textrm{cm}^2$ showed the efficient of 3.15% under air mass 2(AM2) spectrum irradiation with 75mW/$\textrm{cm}^2$.

  • PDF

Applicability Analysis of Head Loss Coefficients at Surcharge Manholes for Inundation Analysis in Urban Area (도시침수해석을 위한 과부하 맨홀의 손실계수 적용성 분석)

  • Kim, Chae Rin;Kim, Jung Soo;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.395-406
    • /
    • 2018
  • The XP-SWMM model, widely used for inundation analysis of urban watersheds, underestimated the inundation area (range) because the manhole was regarded as a node and the influence of the local loss occurring in the surcharged manhole can not be considered. Therefore, it is necessary to analyze the applicability of the head loss coefficients considering the local loss in the surcharged manholes in inundation analysis using XP-SWMM. The Dorim 1 drainage section of the Dorim-river watershed, where frequent domestic flood damage occurred, was selected as the study watershed. The head loss coefficients of the surcharged manholes estimated from the previous experimental studies were applied to the inundation analysis, and the changes of the inundation area with and without the application of the head loss coefficients with manhole types were compared and analyzed. As a result of inundation simulation with the application of head loss coefficients, the matching rates were increased by 17% in comparison with the without application of them. In addition, the simulated inundation area applied only the head loss coefficients of straight path manholes and applied up to the head loss coefficients of combining manholes ($90^{\circ}$ bend, 3-way, and 4-way) were similar. Therefore, in order to accurately simulate the storm drain system in urban areas, it could be to carry out two-dimensional inundation analysis considering the head loss coefficients at the surcharged manholes. It was expected that the study results will be utilized as basic data for establishing the identification of the inundation risk area.

Development of Process for High Deposited Metal Melting Efficiency in TIG Welding Using Filler Wire (필러와이어를 쓰는 TIG용접에서 용착금속의 높은 용융효율을 얻기 위한 공정개발)

  • Shin, Hee-Seop;Ham, Hyo-Sik;Seo, Ji-Seuk;Cho, Sang-Myoung
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.41-41
    • /
    • 2010
  • 에어컨용 냉매 압축기, 냉장고용 냉매압축기 및 자동차 샷시 부품들은 주로 겹치기 필릿용접을 GMAW 으로 실시하고 있다. 그러나 용접 시 스패터 발생으로 인한 추가공수가 요구되며 작업환경 또한 열악한 실정이다. 따라서 저가의 고생산이면서 용접비드의 외관이 미려하고 스패터, 소음 그리고 Fume 이 발생되지 않는 청정한 TIG 용접이 있지만, 용접속도가 수십 cpm 이하로 제한되어 생산성이 낮다는 기술적 모순을 가지고 있다. TIG 용접에서 생산성을 증가시키기 위해 모재와 와이어를 고속 용융 시키려면 전류를 높여 입열량을 증가시켜야 하지만, 증가된 전류로 인하여 상승된 아크력이 험핑비드와 언더컷이 발생되는 물리적 모순을 가진다. 또한 필러와이어를 사용한 기존의 TIG 용접에서 필러 와이어는 주로 원형 단면 와이어를 사용하게 되는데 와이어의 직경이 증가함에 따라 비표면적은 감소하여 용융효율이 낮아지므로 $\Phi$1.2 이하의 필러와이어를 송급하여 용접하였다. 그러나 요구되는 용착량이 큰 경우 필러 와이어를 고속으로 송급하게 되는데 이 경우 필러 와이어 용융이 곤란하거나 송급상의 문제가 자주 생겨 용접속도를 고속으로 하기 곤란하였다. 따라서 필러와이어를 사용한 TIG 용접에서 용착금속의 용융효율을 높게 함으로서 전류를 크게 증가시키지 않으면서도 용접속도를 높일 수 있는 용접 공정개발이 필요한 실정이다. 본 연구에서는 비표면적을 증가시켜 용착금속의 높은 용융효율을 얻을 수 있도록 개발된 와이어와 기존의 $\Phi$3.2 일반와이어 및 를 이용하여 BOP TIG 용접에 비교 실험하였으며, 개발된 와이어와 기존의 $\Phi$1.2 필러와이어를 이용하여 필릿용접부에 적용 실험하여 비교하였다. 그 결과 개발된 와이어의 경우 적절한 비드를 형성하였으나 3.2 일반와이어의 경우 과도한 볼록비드와 불용착부의 문제가 발생하였고, 필릿용접 비교실험에서는 각각 200cpm과 50cpm에서 적절한 비드가 형성되어 더 높은 용착금속 용융효율을 얻을 수 있었다.

  • PDF

Cap Formation Process for MEMS Packages using Cu/Sn Rim Bonding (Cu/Sn Rim 본딩을 이용한 MEMS 패키지의 Cap 형성공정)

  • Kim, S.K.;Oh, T.S.;Moon, J.T.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • To develop the MEMS cap bonding process without cavity formation, we electroplated Cu/Sn rim structures and measured the bonding characteristics for the Cu/Sn rims of $25{\sim}400{\mu}m$ width. As the effective device-mounting area ratio decreased and the failure strength ratio increased for wider Cu/Sn rim, these two properties were estimated to be optimized for the Cu/Sn rim with 150 ${\mu}m$ width. Complete bonding was accomplished at the whole interfaces of the Cu/Sn packages with the rim widths of 25 ${\mu}m$ and 50 ${\mu}m$. However, voids were observed locally at the interfaces with the rim widths larger than 100 ${\mu}m$. Such voids were formed by local non-contact between the upper and lower rims due to the surface roughness of the electroplated Sn.

  • PDF