Warpage and Solder Joint Strength of Stacked PCB using an Interposer (인터포저를 이용한 Stacked PCB의 휨 및 솔더 조인트 강도 연구)

  • Kipoong Kim;Yuhwan Hwangbo;Sung-Hoon Choa
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.40-50
    • /
    • 2023
  • Recently, the number of components of smartphones increases rapidly, while the PCB size continuously decreases. Therefore, 3D technology with a stacked PCB has been developed to improve component density in smartphone. For the s tacked PCB, it i s very important to obtain solder bonding quality between PCBs. We investigated the effects of the properties, thickness, and number of layers of interposer PCB and sub PCB on warpage of PCB through experimental and numerical analysis to improve the reliability of the stacked PCB. The warpage of the interposer PCB decreased as the thermal expansion coefficient (CTE) of the prepreg decreased, and decreased as the glass transition temperature (Tg) increased. However, if temperature is 240℃ or higher, the reduction of warpage is not large. As FR-5 was applied, the warpage decreased more compared to FR-4, and the higher the number and thickness of the prepreg, the lower the warpage. For sub PCB, the CTE was more important for warpage than Tg of the prepreg, and increase in prepreg thickness was more effective in reducing the warpage. The shear tests indicated that the dummy pad design increased bonding strength. The tumble tests indicated that crack occurrence rate was greatly reduced with the dummy pad.

An Experimental Study on the Flexural Behavior of RC Beams Strengthened with High-Strength Bars(1) (고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(1))

  • Shin, Kyung-Jae;Kwak, Myong-Keun;Heo, Byung-Wook;Na, Jung-Min;Oh, Young-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.527-534
    • /
    • 2006
  • This paper outlines a new strengthening technique for concrete beams using externally unbended high-strength bars. The advantages of proposed method lie in speed and simplicity of construction compared to the alternative strengthening method. Externally unbended reinforcement retains many of the advantages over external unbended prestressed tendons. It eliminates time consuming stressing operations. Clearance requirements around anchorages are reduced as access is not required for prestressing jacks. Test results of eight specimens on reinforced concrete beams using different reinforcement materials such as carbon fiber sheet, steel plate and high-tension bar are reported. The beam strengthened by carbon fiber sheet showed a brittle failure mode due to the separation of fiber. As a result of draped profile of external bar, the maximum strength of the beam were increased by up to 212 percent and the deflections were reduced by up to 65 percent. Test results show that the beams reinforced with high-tension bar are superior to reference specimens, especially for the strength and deformation capacity.

DFMT Electromagentic Transducer for Implantable Middle Ear Hearing Aid (이식형 인공중이 시스템을 위한 차동 플로팅매스형 전자 튜랜스듀서)

  • 송병섭;박재훈;윤영호;배상곤;채승표;김명남;이상흔;이건일;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.625-632
    • /
    • 1999
  • 이식형 인공중이에 사용되는 전자트랜스듀서는 압전형 트랜스듀서에 비해 음향특성은 좋으나 부피가 크고 효율이 낮으며 수술시 정밀한 코일-자석 간격 조정이 필요하며, 최근 제안된 FMT 트랜스듀서는 외부 자장의 변화에 민감하다는 문제점이 지적되고 있다. 본 논문에서는 코일-자석 간격조정이 필요 없고 외부자장에 영향을 받지 않는 차동 플로팅메스형 전자 트랜스듀서를 제안하였다. 제안된 방식은 2개의 소형 자석을 같은 극끼리 접합함으로써 외부자장에 대해 영향을 받지 않고 효율이 높은 등의 장점을 가진다. 제안된 트랜스듀서의 진동력 및 효율에 관한 정량적인 해석을 하였으며 기존의 트랜스듀서와 비교분석을 행하였다. 그리고 공급전류에 대해 발생되는 진동력의 크기를 계산함으로서 실제 이식형 인공중이의 제작에 필요한 객관적인 설계데이타를 제시하였다. 한편, 시험 제작된 트랜스듀서의 해석결과 제안한 트랜스듀서는 기존의 FMT 트랜스듀서보다도 효율이 1.5배 정도의 향상됨을 보였으며 무부하시험 및 사체의 이소골 진동실험을 통하여 적절한 진동을 효과적으로 이소골에 전달할 수 있음을 보였다.

  • PDF

Experimental study of Hydraulic Cable Connection Systems with Re-tensioning and Wireless Monitoring (재긴장과 무선 모니터링이 가능한 유압식 케이블 접합부시스템의 실험에 대한 연구)

  • Kim, Min-Su;Lee, Ki-Hak;Kim, Seong-Beom;Lee, Sung-Min;Baek, Ki-Youl
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.71-79
    • /
    • 2011
  • Due to the self-equilibrium status of the cable system, the loss of the tensioning in the cable system results in other cables carrying larger tension forces than those initially calculated by structural engineers. Also, turn-buckle systems, which have been widely used to pre-tension and/or re-tension the cables, are limited to use for small cables and to provide a rough estimation for tension forces. In this study, the re-tensioning cable connection systems were developed to overcome the problems mentioned above. The main objective of the proposed system is to re-tension large cables and measure the exact amount of tension forces of the cable systems. This connection system is also combined with the wireless signal monitoring module so that engineers are able to measure the tension forces any place where the internet is available. This paper presents the development of the re-tensioning cable connection systems and experiment using the real-scale cable systems to verify the fe-tensioning and signal monitoring systems.

A Study on Elasto-Plastic Behavior of Column-to-Beam Welded Connection with 600MPa Class High Performance Steel (600MPa급(SM 570 TMC) 고성능강 기둥-보 용접접합부의 탄소성 거동에 관한 연구)

  • Kim, Jong Rak;Oh, Young Suk;Baek, Ki Youl;Chang, Sung Yun
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.783-792
    • /
    • 2008
  • While the recent high demand for mega-tall buildings has led to the development of high-performance and high-strength steels, the requirements for architectural-structure-performance steel have been raised as engineers recognize the potential damage that an earthquake can wreak on a tall building. A 600MPa-class steel has emerged to meet such need, and many studies are currently exploring its practical applications on civil engineering works and mega-tall buildings. The available data on the horizontal-force behaviors of structures built with such new steel, however, are still insufficient. There is an urgent need to look into its design data, especially its toughness, and to compare the plastic strain ratios of column-to-beam connections using high-strength steel and regular steel. One of the first studies on the behavior of a column-to-beam connection using 600MPa-class steel (SM570 TMC), this thesis analyzes such steel's structural performance by conducting a structural test on seismic resistance on a full-scale column-to-beam welded connection with non-scallop and recommended-scallop details. Compared with the previous studies on SM490, this thesis evaluates the weldability of SM570 TMC and presents the latter's seismic design data for use in testing its practical application.

Pounding Characteristics of a Bridge Superstructure on Rubber Bearings (교량 상부구조물의 탄성받침 설치에 따른 충돌특성 분석)

  • Choi, Hyoung-Suk;Kim, Jung-Woo;Gong, Yeong-I;Cheung, Jin-Hwan;Kim, In-Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.13-21
    • /
    • 2011
  • Seismic structure pounding between adjacent superstructures may induce the destruction of pier and bridge superstructures and cause local damage that leads to the collapse of the whole bridge system. The pounding problem is related to the expansion of joints, gap distance and seismic response of the abutments. In this research, methods of the contact element approach, the linear spring model, the Kelvin-Voigt model and the Hertz model were studied to analyse the pounding characteristics. The shaking table test for a model specimen such as a bridge superstructure with elastomeric bearings was performed to evaluate the contact element approach methods. Relationships between the time history response from the numerical analysis results and the measured response from the shaking table test are compared. The experimental results were not well matched with the numerical analysis results using the existing pounding stiffness models. Therefore, in this study, coefficients are proposed to calculate the appropriate pounding stiffness ratio.

A Experimental Study on the Structural Performance of Column Spliceswith Metal Touch Subjected to Axial Force and Bending Moment (압축력과 휨모멘트를 받는 메탈 터치된 기둥 이음부의 구조성능에 대한 실험적 연구)

  • Hong, Kap Pyo;Kim, Seok Koo;Lee, Joong Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.633-644
    • /
    • 2008
  • The structural framework design uses high-strength bolts and welding in column splices. However, for the column under high compression, the number of the required high-strength bolts can be excessive and the increase of welding results in difficulty of quality inspection, the transformation of the structural steels, and the increase of erection time. According to the AISC criteria, when columns have bearing plates, or they are finished to bear at splices, there shall be sufficient connections to hold all parts securely in place. The Korean standard sets the maximum 25% of the load as criteria. Using direct contact makes it possible to transfer all compressive force through it. The objective of this study is to examine the generally applied stress path mechanism of welded or bolted columns and to verify the bending moment and compression transfer mechanism of the column splice according to metal touch precision. For this study,22 specimens of various geometric shapes were constructed according to the change in the variables for each column splice type, which includes the splice method, gap width, gap axis, presence or absence of splice material, and connector type. The results show that the application of each splice can be improved through the examination of the stress path mechanism upon metal contact. Moreover, the revision of the relative local code on direct contact needs to be reviewed properly for the economics and efficiency of the splices.

Mechanical Reliability Issues of Copper Via Hole in MEMS Packaging (MEMS 패키징에서 구리 Via 홀의 기계적 신뢰성에 관한 연구)

  • Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.29-36
    • /
    • 2008
  • In this paper, mechanical reliability issues of copper through-wafer interconnections are investigated numerically and experimentally. A hermetic wafer level packaging for MEMS devices is developed. Au-Sn eutectic bonding technology is used to achieve hermetic sealing, and the vertical through-hole via filled with electroplated copper for the electrical connection is also used. The MEMS package has the size of $1mm{\times}1mm{\times}700{\mu}m$. The robustness of the package is confirmed by several reliability tests. Several factors which could induce via hole cracking failure are investigated such as thermal expansion mismatch, via etch profile, and copper diffusion phenomenon. Alternative electroplating process is suggested for preventing Cu diffusion and increasing the adhesion performance of the electroplating process. After implementing several improvements, reliability tests were performed, and via hole cracking as well as significant changes in the shear strength were not observed. Helium leak testing indicated that the leak rate of the package meets the requirements of MIL-STD-883F specification.

  • PDF

Fatigue Capacity Evaluation of the Girder-Abutment Connection for the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bar (PS 강봉으로 일체화된 강합성 라멘교의 거더-교대 접합부에 대한 피로 성능 평가)

  • Ahn, Young-Soo;Oh, Min-Ho;Chung, Jee-Seung;Lee, Sang-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.249-258
    • /
    • 2012
  • Integral and rigid frame bridges have advantages in bridge maintenance and structural efficiency by eliminating expansion joints and bridge supports. However, the detail of typical girder-abutment connection is rather complex and increases construction cost depending on construction detail. For the purpose of compensating disadvantages such as complexity and additional cost, a new type of bridge is proposed in this study, which improves the efficiency of construction by simplifying the construction detail of girder-abutment connection. The proposed bridge has the connection detail of steel girder and abutment integrated by prestressed PS bar installed in the connection. In this study, finite element analysis and fatigue load test are conducted to evaluate the fatigue capacity of the proposed girder-abutment connection. The results of the finite element analysis revealed that the possibility of the fatigue damage in the girder-abutment connection is very low. The results of the fatigue load test verified that the integrity of the girder and abutment connection is maintained after 2,000,000 cycles of fatigue loading.

Development of Process for High Deposited Metal Melting Efficiency in TIG Welding Using Filler Wire (필러와이어를 쓰는 TIG용접에서 용착금속의 높은 용융효율을 얻기 위한 공정개발)

  • Shin, Hee-Seop;Ham, Hyo-Sik;Seo, Ji-Seuk;Cho, Sang-Myoung
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.41-41
    • /
    • 2010
  • 에어컨용 냉매 압축기, 냉장고용 냉매압축기 및 자동차 샷시 부품들은 주로 겹치기 필릿용접을 GMAW 으로 실시하고 있다. 그러나 용접 시 스패터 발생으로 인한 추가공수가 요구되며 작업환경 또한 열악한 실정이다. 따라서 저가의 고생산이면서 용접비드의 외관이 미려하고 스패터, 소음 그리고 Fume 이 발생되지 않는 청정한 TIG 용접이 있지만, 용접속도가 수십 cpm 이하로 제한되어 생산성이 낮다는 기술적 모순을 가지고 있다. TIG 용접에서 생산성을 증가시키기 위해 모재와 와이어를 고속 용융 시키려면 전류를 높여 입열량을 증가시켜야 하지만, 증가된 전류로 인하여 상승된 아크력이 험핑비드와 언더컷이 발생되는 물리적 모순을 가진다. 또한 필러와이어를 사용한 기존의 TIG 용접에서 필러 와이어는 주로 원형 단면 와이어를 사용하게 되는데 와이어의 직경이 증가함에 따라 비표면적은 감소하여 용융효율이 낮아지므로 $\Phi$1.2 이하의 필러와이어를 송급하여 용접하였다. 그러나 요구되는 용착량이 큰 경우 필러 와이어를 고속으로 송급하게 되는데 이 경우 필러 와이어 용융이 곤란하거나 송급상의 문제가 자주 생겨 용접속도를 고속으로 하기 곤란하였다. 따라서 필러와이어를 사용한 TIG 용접에서 용착금속의 용융효율을 높게 함으로서 전류를 크게 증가시키지 않으면서도 용접속도를 높일 수 있는 용접 공정개발이 필요한 실정이다. 본 연구에서는 비표면적을 증가시켜 용착금속의 높은 용융효율을 얻을 수 있도록 개발된 와이어와 기존의 $\Phi$3.2 일반와이어 및 를 이용하여 BOP TIG 용접에 비교 실험하였으며, 개발된 와이어와 기존의 $\Phi$1.2 필러와이어를 이용하여 필릿용접부에 적용 실험하여 비교하였다. 그 결과 개발된 와이어의 경우 적절한 비드를 형성하였으나 3.2 일반와이어의 경우 과도한 볼록비드와 불용착부의 문제가 발생하였고, 필릿용접 비교실험에서는 각각 200cpm과 50cpm에서 적절한 비드가 형성되어 더 높은 용착금속 용융효율을 얻을 수 있었다.

  • PDF