Abnormal Vibration of the Steam Turbine Shaft in 500 MW Class Coal-fired Power Plants (500 MW급 석탄화력발전소 증기터빈축 이상진동의 해결방안)

  • Ahn, Kwang-Min;Yoo, HoSeon
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • During the start-up of 500 MW class coal-fired power plant, abnormal shaft vibration was occurred on bearings installed on both side of high and intermediate pressure steam turbine. Shaft vibration was analyzed to investigate the reason and find the resolution, based on well-known theory in this study. Typical vibration characteristics which occur when rotating parts contact with stationary parts were observed at the analysis of frequency, amplitude and phase angle. The reason of abnormal vibration was assumed to be rub and internal parts wear was observed during repair period. As a result of applying low speed turning and balancing for resolution of abnormal vibration, balancing was more effective for rub removal. So balancing could be excellent resolution in the case of abnormal vibration which is similar to this study.

  • PDF

Comparison of the Contact Characteristics for Sealing strips of the Tsunami Damper (쓰나미 댐퍼 시일의 접촉특성 비교)

  • Seo, Ji-Hwan;Kim, Byung-Tak;Chin, Do-Hun;Yoon, Moon-Chul;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • A Tsunami damper, which is installed on the outer wall of a nuclear power plant, is usually used as a ventilation window of the machine room, but can serve as a device for preventing flooding of the machine room when large waves flow over the outer wall. The sealing strip, which is inserted between the casing and the blades, plays an important role in maintaining a watertight environment. In this study, in order to ensure an effective watertight performance of the tsunami damper, FE analysis is conducted to compare the contact characteristics of sealing strips with three different section shapes. In the analysis, the casing and the blade of Tsunami damper are assumed to be rigid bodies; the sealing strip is assumed to be a flexible body. The stress, the strain, and the contact pressure are investigated to examine the sealing performance of each model.

A Study on Dry Friction-Induced Sound (乾性摩찰音 에 관한 硏究)

  • 김재호;김석삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.6
    • /
    • pp.591-598
    • /
    • 1984
  • The results of measurements showing normal vibrations and rubbing noise generated during unlubricated smooth sliding between metal surfaces are presented. The measurements were made on pin-on-disc type apparatus instrumented with piezoelectric acceleration transducers and microphones. Spectral analysis of the both signals up to frequency of 10kHz indicates that they are closely correlated. The major components of both signals in this frequency range are primarily associated with the normal contact vibrations which are excited by surface irregularities being swept through the contact region during sliding. As an approximation to the seismic input of surface irregularities, an effective surface wavenumber spectrum was assumed in the form of an inverse vibration and noise measurements for a number of surface finishes and mean loads. The predominant frequency component of which levels of the normal vibration and noise are close to overall levels of the both signals is induced by contact resonance between the two bodies and its frequency can be calculated from the Hertzian theory.

A study on the Contactless Power Supply System for Linear Driving System (선형 구동 시스템에 적용한 비접촉 전원장치에 관한 연구)

  • Hwang, Gye-Ho;Lee, Yeung-Sik;Moon, In-Ho;Cho, Sang-Joon;Lee, Bong-Sub;Jung, Do-Young;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1045-1046
    • /
    • 2006
  • 최근 반도체 및 FPD 산업에서 Glass의 사이즈, 무게의 증가함에 따라 물류 이송 장비의 전원장치인 비접촉 전원장치의 크기와 용량이 증가하는 추세이며, 또한, 클린룸의 규모가 커짐에 따라 물류 이송 장비 시스템의 길이가 길어지고 Vehicle의 수가 증가하는 추세이다. 본 논문에서는 여러 대의 Vehicle간 독립제어가 가능하고, 물류 이송 장비의 구조가 직선부분과 곡선부분이 혼용되어진 구조에서도 사용 가능한 정전류 비접촉 전원장치의 주요 전력변환 토플로지 별 해로해석, 제어방법을 제시하였고 특히 직 병렬 공진 컨버터의 회로해석, 특성평가를 행하였다. 이 특성평가를 바탕으로 정전류 비접촉 전원장치의 시제품을 제작하여 저항성 부하와 선형 구동 시스템에 적용한 Vehicle 2대를 부하로 사용하여 실험을 행하여 실제 적용, 가능함을 보이고자 한다.

  • PDF

Dynamic Analysis of Catenary System Subjected to Moving Load (이동하중을 받는 일정장력이 작용하는 가선계의 동적해석)

  • Lee, Kyu-Ho;Cho, Yong-Hyun;Chung, Jin-Tai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.1
    • /
    • pp.99-106
    • /
    • 2011
  • In this study, the dynamic contact of a catenary system is analyzed by using the finite element method. We derive the equations of motion for the catenary system by taking into consideration tension on the catenaries. After establishing the weak form, they are spatially discretized with beam elements. Then, we analytically calculated the wave propagation speed for a string, bar, beam, and the catenaries subjected to tension. Further, finite element computer program for contact dynamic analyses is developed. Finally, we analyze the wave propagation response corresponding to the moving load to the contact line are calculated.

투명 전도성 전극에 대한 탄소나노튜브 네트워크 구조 특성과 전기적 특성의 상관관계

  • Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.17.1-17.1
    • /
    • 2011
  • 본 연구에서는 탄소나노튜브 네트워크의 구조 변화에 따른 투명 전도성 필름의 전기적, 광학적 특성 변화를 관찰하였다. 탄소나노튜브 기반 필름의 전기적 특성은 탄소나노튜브의 직경, 길이에 큰 영향을 받을 뿐만 아니라 개별의 탄소나노튜브가 기판에 적층되어 형성되는 네트워크의 구조 변화에도 영향을 받는다. 이에 대해 본 연구에서는 분산제의 종류 및 농도에 따른 용액내 탄소나노튜브의 분산도, 산소 플라즈마 처리에 따른 기판의 표면장력, 탄소나노튜브의 정제에 따른 순도를 변화 시켰으며, 이에 따른 탄소나노튜브 네트워크 구조변화를 관찰하였다. 또한, 탄소나노튜브 네트워크의 구조변화에 따른 전기적, 광학적 특성 변화를 관찰하고, 이를 통해 탄소나노튜브 필름의 전기적 특성에 개별 탄소나노튜브간에 발생하는 접촉저항의 영향을 논의하였다.

  • PDF

A test result of dynamic character about low voltage electric machine under voltage sags (순간전압강하에 대한 저압기기의 응동특성 실험결과)

  • Lee, Geun-Joon;Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jea-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.40-42
    • /
    • 2007
  • 본 논문은 전기기기에 순간전압저하를 발생 하였을 경우 응동특성에 대한 영향을 계측하였다. 실험 방법은 AVR에서 Sag 발생기인 IPC에 입력한 후, IPC에서 전압의 크기와 시간을 조정하여 실험기기에 순간전압 강하를 발생하였다 실험기기는 PLC, 전자접촉기, 400[W]고압방전램프를 시험하였다. PLC시험에서 무부하와 정격부하에 따라 특성 의 변화가 생겼으며, 정격부하에서 Voltage Sag의 영향을 더 받았다 전자접촉기의 시험은 위상을 $0^{\circ},\;30^{\circ},\;60^{\circ},\;90^{\circ}$로 변화하여 Voltage Sag 발생시켜 계측하였으며, 위상의 변화에 따라 특성곡선이 변화하였다. 고압방전램프시험은 고압나트륨램프와 수은램프, 메탈헬라이드에 Voltage Sag를 발생시켰다. 방전램프의 시험결과 고압나트륨램프의 특성곡선이 가장 안정적으로 나타났다. 본 실험을 통해 순간전압저하에 대한 저압기기의 특성을 실험적으로 입증하여 전력시스템의 설계에 영향을 미칠 것이라 기대된다.

  • PDF

Nondestructive measurement of surface resistance of indium tin oxide(ITO) films by using a near-field scanning microwave microscope (근접장 마이크로파 현미경을 이용한 ITO 박막의 표면저항의 비파괴 관측 특성 연구)

  • Yun, Soon-Il;Na, Sung-Wuk;You, Hyun-Jun;Lee, Yeong-Joo;Kim, Hyun-Jung;Lee, Kie-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.137-141
    • /
    • 2004
  • 저항특성이 다른 ITO박막의 구조특성과 표면특성을 XRD와 AFM(atomic force microscopy), SEM(scanning electron microscopy)을 이용하여 관측하였다. 접촉방식인 4단자 법을 사용하여 ITO박막의 표면전기저항을 측정하였다. 관측된 구조 및 표면특성을 바탕으로 비파괴 비접촉방식을 이용한 근접장 마이크로파 현미경을 이용하여 얻은 ITO박막의 표면저항특성과 비교 연구하였다.

  • PDF

폴리머 애자의 자기세정 응용을 위한 듀얼 마그네트론 스퍼터링 장치에 의해 증착되어진 TiOx 박막의 특성

  • Park, Yong-Seop;Park, Cheol-Min;Park, Yeong;Kim, Hyeong-Cheol;Jeong, Ho-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.445-445
    • /
    • 2012
  • 본 연구에서는 폴리머 애자의 자기 세정을 위한 소재로써 TiOx 박막을 실리콘, 유리, 그리고 폴리머 애자에 듀얼 RF 마그네트론 스퍼터링 장치를 이용하여 증착하였다. 타겟으로는 TiO2 타겟을 사용하였으며, 스퍼터링 가스로는 아르곤을 사용하였다. TiOx 박막은 스퍼터링의 조건 중 RF 파워의 크기에 따라 100 nm의 두께로 증착하였다. RF 파워에 따라 증착되어진 TiOx 박막은 접촉각, 표면 거칠기등을 분석하여 표면 특성을 고찰하였으며, UV-visible, 굴절율, 누설전류등을 측정하여 TiOx 박막의 광학적 특성과 전기적 특성을 평가하였으며, 구조 특성 분석을 통하여 이 특성들 사이의 관계를 규명하였다.

  • PDF