• Title/Summary/Keyword: 접착전단강도

Search Result 314, Processing Time 0.026 seconds

Comparative evaluation of micro-shear bond strength between two different luting methods of resin cement to dentin (합착 술식에 따른 레진 합착제의 상아질에 대한 미세전단결합강도의 비교 연구)

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.283-293
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.

Shear bond strength of brackets bonded with different self etching primers (Self etching primer를 사용하여 부착된 교정용 브라켓의 전단결합강도의 비교)

  • Yang, Jin-Young;Kim, Min-Ji;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • The purpose of this study was to evaluate the clinical usefulness of 4 self etching primers by measuring the shear bond strength of orthodontic brackets and examining the failure pattern of bracket-tooth interfaces. Methods: Seventy-five, defect-free, premolars were randomly assigned into five groups: control group (37% phosphoric acid + Transbond XT primer) and self etching primer treated groups (Transbond Plus self etching primer, Unifil bond, Clearfil SE bond, and Adhese). The shear bond strength was measured with a universal testing machine and the amount of residual adhesive remaining on the brackets after debonding was assessed by the adhesive remnant index (ARI). Results: The results showed that the groups conditioned with self etching primer had significantly lower shear bond strength than the control group (p < 0.05), although clinically acceptable. However, there were no significant differences in shear bond strength among the self etching primer groups (p > 0.05). Evaluation of the ARI scores indicated there was less resin remnant on the teeth in the groups conditioned with self etching primers, although not statistically significant. Conclusion: The results of this study suggest that all four of the self etching primers have shown acceptable bond strength for clinical use.

PHYSICAL PROPERTIES OF DIFFERENT SELF-ADHESIVE RESIN CEMENTS AND THEIR SHEAR BOND STRENGTH ON LITHIUM DISILICATE CERAMIC AND DENTIN (수종의 자가 접착 레진 시멘트의 물성 및 lithium disilicate ceramic과 상아질에 대한 전단결합강도 비교)

  • Shin, Hye-Jin;Song, Chang-Kyu;Partk, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.184-191
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different self-adhesive resin cements and their shear bond strength on dentin and lithium disilicate ceramic and compare these result with that of conventional resin cement. For this study, four self-adhesive resin cements (Rely-X Unicem, Embrace Wetbond, Mexcem, BisCem), one conventional resin cement (Rely-X ARC) and one restorative resin composite (Z-350) were used. In order to evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. To evaluate the shear bond strength on dentin, each cement was adhered to buccal dentinal surface of extracted human lower molars. Dentin bonding agent was applied after acid etching for groups of Rely-X ARC and Z-350. In order to evaluate the shear bond strength on ceramic, lithium disilicate glass ceramic (IPS Empress 2) disks were prepared. Only Rely-X ARC and Z-350 groups were pretreated with hydrofluoric acid and silane. And then each resin cement was adhered to ceramic surface in 2 mm diameter. Physical properties and shear bond strengths were measured using a universal testing machine. Results were as follows 1. BisCem showed the lowest compressive strength, diametral tensile strength and flexural strength. (P<0.05) 2. Self-adhesive resin cements showed significantly lower shear bond strength on the dentin and lithium disilicate ceramic than Rely-X ARC and Z-350 (P<0.05) In conclusion, self-adhesive resin cements represent the lower physical properties and shear bond strength than a conventional resin cement.

Microshear bond strength of a flowable resin to enamel according to the different adhesive systems (접착시스템의 종류에 따른 유동성 레진과 법랑질의 미세전단 결합강도)

  • Kim, Jeong-Ho;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • Objectives: The purpose of this study was to compare the microshear bond strength (uSBS) of two totaletch and four self-etch adhesive systems and a flowable resin to enamel. Materials and Methods: Enamels of sixty human molars were used. They were divided into one of six equal groups (n = 10) by adhesives used; OS group (One-Step Plus), SB group (Single Bond), CE group (Clearfil SE Bond), TY group (Tyrian SPE/One-Step Plus), AP group (Adper Prompt L-Pop) and GB group (G-Bond). After enamel surfaces were treated with six adhesive systems, a flowable composite resin (Filek Z 350) was bonded to enamel surface using Tygon tubes. the bonded specimens were subjected to uSBS testing and the failure modes of each group were observed under FE-SEM. Results: 1. The uSBS of SB group was statistically higher than that of all other groups, and the uSBS of OS, SE and AP group was statistically higher than that of TY and GB group (p < 0.05). 2. The uSBS for TY group was statistically higher than that for GB group (p < 0.05). 3. Adhesive failures in TY and GB group and mixed failures in SB group and SE group were often analysed. One cohesive failure was observed in OS, SB, SE and AP group, respectively. Conclusions: Although adhesives using the same step were applied the enamel surface, the uSBS of a flowable resin to enamel was different.

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Effects of Adherend Thickness on Adhesive Strength between Organic Adhesive and Metal Adherend (고분자 접착제와 금속 피착재의 접착강도에 미치는 피착재 두께의 영향)

  • Ha, Yungeun;Sim, Jun-Hyung;Baeg, Ju-Hwan;Kim, Min-Kyun;Cho, Young-Rae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.127-133
    • /
    • 2020
  • It is important to measure the quantitative adhesive strength between an organic adhesive and a metal adherend. In measuring the adhesive strength between an organic adhesive and a metal adherend, the effect of the kind and thickness of the adherend on the adhesive strength was studied. Two kinds of metal adherends were selected, aluminum (Al1050) and stainless steel (STS304), and a dolly test and a lap shear test were used to measure the adhesive strength. When measuring the adhesive strength between the organic adhesive and the metal adherend by the tensile stress mode of dolly test, the change in the thickness of the metal adherend had little effect on the adhesive strength, however, the adhesive strength was different depending on the kind of the adherend. On the other hand, when measuring the adhesive strength between the organic adhesive and the metal adherend by the lap shear test, the change in the relative thickness of the metal adherend had an effect on the adhesive strength. The reason is that the bending phenomenon of the adherend occurring in the edge of bonding region during the lap shear test contributes to lowering the adhesive strength by generating additional tensile stress in the bonding region. From this work, it is concluded that the dolly test could be widely used when measuring the quantitative adhesive strength of organic adhesives and metal adherend because there is little change in adhesive strength even though the thickness of the adherend is changed.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A Study of shear bond strength of bonded retainer according to the bonding method and type of wires (접착방법 및 multistranded wire의 종류에 따른 접착식 보정장치의 전단접착강도에 관한 연구)

  • Lee, Hyoung-Cheol;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.143-153
    • /
    • 2002
  • The bonded orthodontic retainer constructed from composite and multistrand orthodontic wire provides an esthetic and efficient system for maintained retention. This study was designed to measure shear bond strength of bonded retainers and to suggest a optimal combination of a multistrand wire and bonding method used when bonded retainer was fabricated. 160 sound maxillary and mandibular premolars were used for 80 test samples. After Uniformizing bonding area, length of wire, and thickness of composite, multistrand wire was bonded to fabricated a bonded retainer by direct or indirect bonding method. Shear bond strength and extension length of each sample were measured by a universal testing machine. The results of this study were as follows : 1. In vitro shear bond testing found 6-stranded, 0.0155 inch wires to have the largest shear bond strength and 3-stranded, 0.0195 inch wires to have the least shear bond strength. But, These difference was not statistically significant(p<0.05). 2. In vitro extension testing found 3-stranded, 0.0155 inch wires to have the largest extension length and 3-stranded, 0.0195 inch wires to have the least extension length(p<0.05). The larger diameter wire was used, the larger extension length was shown. But, the strand of wire is not related to the extension length of wire. 3. In comparison with direct bonding method, larger shear bond strength and extension length was shown in indirect bonding method(p<0.05).

Effect of thermocycling on shear bond strength and mode of failure of ceramic orthodontic brackets bonded to different porcelain restorations (수 종의 도재 수복물에 부착된 세라믹 브라켓의 전단접착강도와 파절양상에 열순환이 미치는 영향)

  • Kang, Sang-Wook;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.225-233
    • /
    • 2009
  • Objective: The purpose of this study was to investigate the effect of thermocycling and type of porcelain restoration on shear bond strength (SBS) and mode of failure of monocrystalline ceramic brackets. Methods: A total of 60 porcelain discs were made and divided into three equal groups as follows: Ceramco 3, IPS Empress II, Zi-ceram/Vintage ZR. ceramic brackets were bonded to the prepared porcelain surfaces in the same manner. Each group was divided randomly into two subgroups: thermocycled group and non-thermocycled group (control). All samples were tested in shear mode on an universal testing machine. Results: SBS of the non-thermocycled group was clinically acceptable (Ceramco 3: $7.06\;{\pm}\;1.76\;MPa$, IPS Empress II: $7.55\;{\pm}\;2.38\;MPa$, Zi-ceram/Vintage ZR: $7.19\;{\pm}\;1.38\;MPa$). But, SBS of the thermocycled group was significantly reduced (Ceramco 3: $4.88\;{\pm}\;1.00\;MPa$, IPS Empress II: $5.46\;{\pm}\;1.35\;MPa$, Zi-ceram/Vintage ZR: $4.84\;{\pm}\;1.01\;MPa$, p < 0.05). There was no difference between the shear bond strength by type of porcelain restoration. All bonding failure occurred between bracket base and adhesive, except for 2 samples. Conclusions: The results of this study suggest that the type of porcelain restoration did not affect SBS, but thermocycling weakened SBS. Therefore, the effect of thermocycling should be considered when using ceramic brackets in practice.

Micro-shear bond strength of resin-modified glass ionomer and resin-based adhesives to dentin (상아질 위치에 따른 접착성 수복재의 미세전단결합강도에 관한 연구)

  • Hong, Hyun-Kyung;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.314-325
    • /
    • 2003
  • 이 연구의 목적은 수종 상아질 접착 시스템과 복합 레진 및 resin-modified glass ionomer를 상아질 표면에 접착하여 재료 및 상아질내 위치에 따른 미세전단결합강도를 측정, 비교하는 것이다. 상아질 접착 시스템으로는, 3-step인 Scotchbond Multi-Purpose Plus, 2-step인 Single Bond와 자가 부식형 시스템인 Clearfil SE Bond를, 1-step인 Prompt L-Pop을 사용하였다. 이와 함께 hybrid type의 복합 레진인 Clearfil AP-X와 2250을 사용하였으며 resin-modified glass ionomer로는 Fuji II LC를 사용하였다. 상악 소구치를 치아의 근원심 중앙부를 절단하여 상아질면을 노출시켰다. 5개 실험군으로 분류하고 상아질면을 위치에 따라 치관부의 occlusal $\frac{1}{3}$, middle $\frac{1}{3}$, cervical $\frac{1}{3}$과 치근부로 구분지어 시편을 부착하였다. 미세전단결합강도측정는 Universal testing machine(EZ-test; Shimadzu, Japan)에서 측정하였다. Occlusal 1/3부위에서는 SE가 가장 높은 값을, SM과 SB간에는 유의차가 없었으며, PL, GI순으로, Middle 1/3부위에서는 $SM{\;}{\geq}{\;}SE{\;}{\geq}{\;}SB{\;}{\geq}{\;}PL{\;}{\geq}{\;}GI$순으로, cervical 1/3부위에서는 SM, SE, SB간에 유의차가 없었다. Root dentin에서는 SM이 가장 높은 값을 보였으며 SE, PL, GI간에 유의차가 없었다. SE만이 치관부 상아질에 비해 치근부에서 유의할만한 결합강도의 감소를 나타냈다(p<0.05). GI는 치관부 상아질에서는 다른 군에 비해 유의성 있게 낮은 결합강도를 보였으나 치근부에서는 SE, PL과 유의차가 없었다.