• Title/Summary/Keyword: 접선조사

Search Result 94, Processing Time 0.032 seconds

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

Assessment of Set-up Accuracy in Tangential Breast Treatment Using Electronic Portal Imaging Device (EPID 영상을 이용한 유방암 접선조사의 정확성 평가)

  • Lee, Byung-Koo;Kang, Soo-Man
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.249-254
    • /
    • 2012
  • The aim of this study was to investigate the setup accuracy for tangential breast treatment patients using electronic portal image and 2-D reconstruction image Twenty two patients undergoing tangential breast treatment. To explore the setup accuracy, distances between chosen landmarks were taken as reference parameters. The difference between measured reference parameters on simulation films and electronic portal images (EPIs) was calculated as the setup error. A total of 22 simulation films and 110 EPIs were evaluated. In the tangential fields, the calculated reference parameters were the central lung distance (CLD), central soft-tissue distance (CSTD), and above lung distance (ALD), below lung distance (BLD). In the medial tangential field, the average difference values for these parameters were 1.0, -6.4, -2.1 and 2.0, respectively; and the ${\sigma}$ values were 1.5, 2.3, 4.1 and 1.1, respectively. In the lateral tangential field, the average difference values for these parameters were -1.5, -4.3, -2.7 and -1.3, respectively; and the ${\sigma}$ values were 3.3, 2.1, 2.9 and 2.5, respectively. CLD, CSTD, ALD and BLD in the tangential fields are easily identifiable and are helpful for detecting setup errors using EPIs in patients undergoing tangential breast radiotherapy treatment.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

Consideration Regarding the Breast Cancer Treatment Plan That Used Irregular Surface Compensator (ISC) (Irregular Surface Compensator (ISC)를 이용한 유방암치료계획에 관한 고찰)

  • Je, Young-Wan;Kim, Chan-Yong;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.131-141
    • /
    • 2007
  • Purpose: Try to compare dose distribution and lung dose of radiation treatment plan of the breast cancer that used Irregular Surface Compensator (ISC) and treatment plan that used a wedge filter. Materials and Methods: Established a treatment plan to be distributed over 95% of prescription dose (5,040 cGy) of the two tangent-half fields that used a wedge filter and ISC at a breast organization as made to breast cancer patient having an irregular surfaces after surgery. Compared high dose area and DVH, and verified a treatment plan as used film with rectangular phantom. Results: Maximum dose point in breast tissue appeared to 107.5% in case of tangent-half fields Tx plan that used a wedge filter, and lung volumes exposed above 20 Gy by 7.63%. In case of ISC, maximum dose point in breast tissue appeared to 106.4%, and lung volumes exposed above 20 Gy by 6.5%. The film measurement results that used phantom, 105$\sim$110% high dose region was distributed to the upper part and both edges of phantom. However in case of ISC, appeared by 100$\sim$105% dose conformity distribution. Conclusion: In general, the Irregular Surface Compensator (ISC) can improve the dose conformity of breast tissues, as well as reduced hot spots in the lung and in the breast. Such an advantage by using ISC technique is more beneficial for patients who have more irregular surfaces after surgery.

  • PDF

페르세우스 은하든의 속도 불균질성에 관한 고찰

  • 송두종
    • Bulletin of the Korean Space Science Society
    • /
    • 1992.10a
    • /
    • pp.9-9
    • /
    • 1992
  • 페르세우스(Abell 426)은하단 성분은하들의 관측된 적색편이 조사 목록을 바탕으로 속도분산 값의 위치각에 따른 변화를 살펴 봄으로서 속도분포의 불균질성을 조사하였다. 속도분포의 불균질성을 위치에 따른 은하들의 접선궤도와 중심방향 궤도 지배 정도로서 살펴 보았다. 중심을 기준으로 한 환에 포함된 은하들의 속도분산은 광학과 X-선 관측을 통하여 알아 낸, 은하단이 길쭉한 방향으로 정의한, 위치각 지역에서 중심방향 궤도성분이 지배적이고 접선 방향 궤도는 이와 수직한 지역에서 지배적임을 알 수 있었다. 이러한 속도 분포의 방향성과 광학 및 X-선 관측을 토\ulcorner謗\ulcorner알아 낸 은하단의 위치각 사이 사관관계가 가지는 중요성을 최근의 X-선 관측을 통하여 알아낸 은하단 중심부에서 보이고 있는 저온 물질의 몰입을 중심으로 논하였다.

  • PDF

Anatomical Properties of Major Planted and Promising Species Growing in Indonesia (인도네시아산 주요 조림 및 유망 수종의 해부학적 특성)

  • Kim, Jong-Ho;Jang, Jae-Hyuk;Kwon, Sung-Min;Febrianto, Fauzi;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.244-256
    • /
    • 2012
  • The anatomical characteristics of the ten Indonesian wood species (Gmelina, Jeunjing, Mangium, Durian, Gandaria, Jengkol, Kupa, Mangga, Nanaka and Rambutan) were investigated by optical microscopy. All the species were diffuse-porous with solitary and radial pore multiple. In Mangium, however, tangential pore multiple was observed as well. Tangential diameter of pore was larger than that of radial one except for Jeunjing and Nangka. Nangka showed the largest tangential diameter of pore among the species. Vessel number per $mm^2$ of Mangium, Gandaria and Kupa was higher than that of the other species. Especially Kupa showed highest vessel number. The tangential width of axial parenchyma cell in Gmelina, Mangium, Kupa and Mangga was larger than that of wood fiber, while the other species showed the opposite trend. Mangium was the largest in tangential width of axial parenchyma cell. Rays were homocellular composed only of procumbent cell in Gmelina, Jeunjing and Rambutan. Heterocellular rays composed of procumbent cells in the body and one row of upright and/or square in the margin are observed in Gandaria. Mangium, Durian, Jengkol, Kupa, Mangga and Nangkabody showed heterocellular rays composed of procumbent cells in the body and mostly 1~2 rows of upright and/or square cells in the margin. Crystals occurred in Durian, Gandaria, Jengkol, Jeunjing, Mangga and Rambutan and silica in Jeunjing and Mangga.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Modified Arc-Length Method of Riks (Riks Method를 이용한 비선형 수치해석)

  • jae-Wook Lee;Young-Tae Yang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.182-188
    • /
    • 1991
  • The modified arc-length algorithms for the automatic incremental solution of nonlinear finite element equations proposed by Riks are presented, which comprise the cylindrical arc-length method and the normal arc-length method. These methods are developed to trace the nonlinear path of large displacement problems such as a pre and post bucking/collapse response of general structures. These methods are applied to analyse the nonlinear behavior of arch and shell problems in parallel with the standard and modified Newton-Raphson method.

  • PDF