• Title/Summary/Keyword: 접근제어 모델

Search Result 520, Processing Time 0.027 seconds

An Overview of Fault Diagnosis and Fault Tolerant Control Technologies for Industrial Systems (산업 시스템을 위한 고장 진단 및 고장 허용 제어 기술)

  • Bae, Junhyung
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.548-555
    • /
    • 2021
  • This paper outlines the basic concepts, approaches and research trends of fault diagnosis and fault tolerant control applied to industrial processes, facilities, and motor drives. The main role of fault diagnosis for industrial processes is to create effective indicators to determine the defect status of the process and then take appropriate measures against failures or hazadous accidents. The technologies of fault detection and diagnosis have been developed to determine whether a process has a trend or pattern, or whether a particular process variable is functioning normally. Firstly, data-driven based and model-based techniques were described. Secondly, fault detection and diagnosis techniques for industrial processes are described. Thirdly, passive and active fault tolerant control techniques are considered. Finally, major faults occurring in AC motor drives were listed, described their characteristics and fault diagnosis and fault tolerant control techniques are outlined for this purpose.

A Study of Methodology Based on Role-Based Serucity Agent Medical Information System Security Architecture Design (보안 에이전트 역할 기반에 기초한 의료정보시스템 소프트웨어 보안아키텍쳐 설계방안)

  • Lee, Dae-Sung;Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.11 no.4
    • /
    • pp.77-83
    • /
    • 2011
  • In addition to the rapid development of health information technology services for the development of new medical information, a lot of research is underway. Improve health care services for patients are many ways to help them. However, no information about the security, if only the technology advances in health care systems will create an element of risk and threat. Today's issues and access issues are stable over a public network. Ad hocsensor network using secure, non-integrated health information system's security vulnerabilities does not solve the security vulnerabilities. In the development and utilization of health information systems to be subject to greater restrictions. Different security policies in an environment with a medical information system security policy mechanism that can be resolved if people get here are needed. Context-aware and flexible policy of integration and confidential medical information through the resistance should be guaranteed. Other cross-domain access control policy for telecommunications should be protected. In this paper, that the caller's medical information system, diversification, diversification Security agent in the environment, architecture, design, plan, role-based security system are proposed. The proposed system architecture, design work in the field and in the utilization of one model are expected to be.

SecureJS : A Secure JavaSpace based on Jini2.0 (SecureJS : Jini2.0 기반의 안전한 JavaSpace)

  • Yu Yang-Woo;Moon Nam-Doo;Jung Hye-Young;Lee Myung-Joon
    • The KIPS Transactions:PartC
    • /
    • v.11C no.7 s.96
    • /
    • pp.999-1008
    • /
    • 2004
  • The Jini system provides an infrastructure to facilitate a programmer to develop distributed systems. As one of the Jini services, JavaSpare has been used as a repository which is accessible publicly in the Java distributed environment. Although JavaSpace could give a useful method for saving and sharing java object, it would not be applicable to develop a distributed system requiring access securities for the objects because JavaSpare does not support secure access control. In this paper, we present a secure JavaSpare service based on Jini2.0 named SeureJS, which strengthens the security weakness of JavaSpare. The system consists of ObjectStore to store Java objects, AccessManager to control access of ObjectStore and KeyManager to manage public keys.

Dynamic Model Considering the Biases in SP Panel data (SP 패널데이터의 Bias를 고려한 동적모델)

  • 남궁문;성수련;최기주;이백진
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.6
    • /
    • pp.63-75
    • /
    • 2000
  • Stated Preference (SP) data has been regarded as more useful than Revealed Preference (RP) data, because researchers can investigate the respondents\` Preference and attitude for a traffic condition or a new traffic system by using the SP data. However, the SP data has two bias: the first one is the bias inherent in SP data and the latter one is the attrition bias in SP panel data. If the biases do not corrected, the choice model using SP data may predict a erroneous future demand. In this Paper, six route choice models are constructed to deal with the SP biases, and. these six models are classified into cross-sectional models (model I∼IH) and dynamic models (model IV∼VI) From the six models. some remarkable results are obtained. The cross-sectional model that incorporate RP choice results of responders with SP cross-sectional model can correct the biases inherent in SP data, and also the dynamic models can consider the temporal variations of the effectiveness of state dependence in SP responses by assuming a simple exponential function of the state dependence. WESML method that use the estimated attrition probability is also adopted to correct the attrition bias in SP Panel data. The results can be contributed to the dynamic modeling of SP Panel data and also useful to predict more exact demand.

  • PDF

Comparative study of laminar and turbulent models for three-dimensional simulation of dam-break flow interacting with multiarray block obstacles (다층 블록 장애물과 상호작용하는 3차원 댐붕괴흐름 모의를 위한 층류 및 난류 모델 비교 연구)

  • Chrysanti, Asrini;Song, Yangheon;Son, Sangyoung
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.spc1
    • /
    • pp.1059-1069
    • /
    • 2023
  • Dam-break flow occurs when an elevated dam suddenly collapses, resulting in the catastrophic release of rapid and uncontrolled impounded water. This study compares laminar and turbulent closure models for simulating three-dimensional dam-break flows using OpenFOAM. The Reynolds-Averaged Navier-Stokes (RANS) model, specifically the k-ε model, is employed to capture turbulent dissipation. Two scenarios are evaluated based on a laboratory experiment and a modified multi-layered block obstacle scenario. Both models effectively represent dam-break flows, with the turbulent closure model reducing oscillations. However, excessive dissipation in turbulent models can underestimate water surface profiles. Improving numerical schemes and grid resolution enhances flow recreation, particularly near structures and during turbulence. Model stability is more significantly influenced by numerical schemes and grid refinement than the use of turbulence closure. The k-ε model's reliance on time-averaging processes poses challenges in representing dam-break profiles with pronounced discontinuities and unsteadiness. While simulating turbulence models requires extensive computational efforts, the performance improvement compared to laminar models is marginal. To achieve better representation, more advanced turbulence models like Large Eddy Simulation (LES) and Direct Numerical Simulation (DNS) are recommended, necessitating small spatial and time scales. This research provides insights into the applicability of different modeling approaches for simulating dam-break flows, emphasizing the importance of accurate representation near structures and during turbulence.

LCU-Level Rate Control for HEVC Considering Hierarchical Coding Structure (HEVC의 계층적 부호화 구조를 고려한 LCU 단위의 비트율 제어 기법)

  • Park, Dong-Il;Kim, Jae-Gon;Lim, Sung-Chang;Kim, Jong-Ho;Kim, Hui-Yong
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.762-772
    • /
    • 2011
  • In this paper, a method of rate control for constant bitrate (CBR) coding of High Efficiency Video Coding (HEVC) is addressed. The existing rate control of H.264/AVC may not provide exact rate control in the case of hierarchical coding structure since it doesn't consider the characteristics of the hierarchical coding structure. It is expected that a rate control is added to the reference software called HM for CBR encoding in the near future. More accurate rate control may be required in a hierarchical structure of random access (RA) mode defined in the common test condition of HM. In this paper, we propose a method of rate control based on quadratic Rate-Distortion (R-D) model considering temporal layers and frame types in hierarchical coding structure for efficient rate control. In the consideration of the trade-off relationship between the bit fluctuation and the average PSNR, both of frame and coding unit (CU) are set as the basic unit of rate control. The performance of the proposed rate control method is verified by simulations along with the trade-off relationships for the both cases of basic unit.

A Study on the automatic vehicle monitoring system based on computer vision technology (컴퓨터 비전 기술을 기반으로 한 자동 차량 감시 시스템 연구)

  • Cheong, Ha-Young;Choi, Chong-Hwan;Choi, Young-Gyu;Kim, Hyon-Yul;Kim, Tae-Woo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • In this paper, we has proposed an automatic vehicle monitoring system based on computer vision technology. The real-time display system has displayed a system that can be performed in automatic monitoring and control while meeting the essential requirements of ITS. Another advantage has that for a powerful vehicle tracking, the main obstacle handing system, which has the shadow tracking of moving objects. In order to obtain all kinds of information from the tracked vehicle image, the vehicle must be clearly displayed on the surveillance screen. Over time, it's necessary to precisely control the vehicle, and a three-dimensional model-based approach has been also necessary. In general, each type of vehicle has represented by the skeleton of the object or wire frame model, and the trajectory of the vehicle can be measured with high precision in a 3D-based manner even if the system has not running in real time. In this paper, we has applied on segmentation method to vehicle, background, and shadow. The validity of the low level vehicle control tracker was also detected through speed tracking of the speeding car. In conclusion, we intended to improve the improved tracking method in the tracking control system and to develop the highway monitoring and control system.

Design and Implementation of Web-Based Assessment System PAS for Increasing the Usability in Informatics Education (정보 교육에서의 사용성(Usability) 향상을 위한 웹기반 평가시스템 PAS의 설계 및 구현)

  • Yeum, YongChul;Yoo, SeungWook;Kim, Yong;Lee, WonGyu
    • The Journal of Korean Association of Computer Education
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Web-based Assessment System is needed for Process-Oriented Evaluation to integrate instructions into evaluation frequently in Informatics Education, and considered usability for supporting teachers to test more conveniently. First of all, we analyzed usability of traditional Web-based Assessment System, and proposed PBA(Paper-Based Assessment) model by extracting usability features of paper-pencil assessment in off-line. The evaluation system based on the PBA model controls the whole processes of tests; before-test, under-test, after-test. Especially, the system readily can change the target class, and control access to the test page during each step. Thus we can get high credibility about the test results. Moreover, students can login to the paper easily by using their grade, class, number and name. Finally, we designed and implemented the Web-based Assessment System for Informatics education on the basis of PBA model; PAS(PBA-based Assessment System).

  • PDF

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

Development and Application of Process Model for Description of Load Change of Boiler Plant in High Load (고부하에서의 보일러 플랜트 부하변동 묘사를 위한 프로세스 모델 개발 및 적용)

  • Park, Jeong;Lee, Ki-Hyun;Yang, Li-Ming;In, Jong-Soo;Park, Seok-Ho;Kweon, Sang-Hyeok;Oh, Dong-Han
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-51
    • /
    • 1997
  • A dynamic mathematical model of a thermal power plant with a single drum-type boiler is described with the base on modular concept. The present process model, which is including full scope of the components and high load changes, is based on physical approach through lumped parameters. The module, which means a component of the power plant and must essentially depict the characteristics of the component well, might be interconnected using pressure nodal method in a arrangement determined by users. With the results of the load changes of 75 MW to 95 MW and 95MW to 75 MW with the rate of 3 MW/min, the applicability of the process model is examined connecting to DCS(Dispersion Control System), which has a real running logic of 100 MW real power plant.

  • PDF