• Title/Summary/Keyword: 점 전극

Search Result 259, Processing Time 0.028 seconds

A Review on 3D Structure Formation, Analysis and Performance Prediction Technique for All-solid-state Electrode and Battery (3차원 전고체 전극 구조체 형성, 분석 및 성능 예측 기술 동향)

  • Park, Joonam;Jin, Dahee;Kim, Dohwan;Bae, Kyung Taek;Lee, Kang Taek;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.22 no.4
    • /
    • pp.139-147
    • /
    • 2019
  • Lithium-ion battery (LiB) with high energy density and efficiency has been utilized for the electric vehicle (EV) and energy storage system (ESS) as well as portable devices. However, as explosion accidents have frequently happened till lately, all-solid-state lithium secondary battery (ALSB) began to get in a spotlight because it can secure a very high safety and energy density by substituting flammable organic liquid electrolyte to nonflammable inorganic solid electrolyte. In spite of ALSB's certain merits, it has shown much poorer performance of cells than one of LiB due to some challenges, which have been small or never dealt with in the LiB system. Hence, although plenty of studies made progress to solve them, an approach about design of all-solid-state electrode (ASSE) has been limited on account of difficulty of ALSB's experiments. That is why the virtual 3D structure of an all-solid-state electrode has to be built and used for the prediction of cell performance. In this study, we elucidate how to form the 3D ASSE structure and what to be needed for the simulation of characteristics on ALSB. Furthermore, the ultimate orientation of 3D modeling and simulation for the study of ALSB are briefly suggested.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.

Correlations between Process Variables and Weld Quality in Resistance Spot Welding Processes (저항 점 용접법에서의 용접 변수와 용접품질과의 상관관계에 대한 실험적 고찰)

  • 조형석;전동휘
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.3
    • /
    • pp.257-263
    • /
    • 1984
  • 저항 점 용접시 발생하는 어려운 문제점의 하나는 아무리 동일한 용접조건 하에서 용접을 한다하 더라도 균일한 용접품질을 얻을 수 없다는 점이다. 이는 주로 용접중의 전원에서의 변화로 인한 용접전류 및 전압변동, 용접모재의 표면상태 및 두께의 불균일, 두 전극의 마멸 및 맞춤상태 등의 인자 때문에 기인한다고 볼 수 있다. 이러한 문제점을 해결하기 위해서는 용접하는 도중에 수시 로 인자 때문에 기인한다고 볼 수 있다. 이러한 문제점을 해결하기 위해서는 용접하는 도중에 수 시로 용접 상태를 점검하여 용접조건을 그때 그때에 적합하게 변화시켜 주는 것이 바람직한데 우 선 용접상태를 판별하기 위해서는 용접품질(weld quality)을 잘 대변할 수 있는 용접법 변수를 찾 아내는 것이 중요한 일이다. 따라서 본 논문에서는 용접품질에 관련되는 변수중, 전기동저항과 전 극분리현상을 측정해서 마이크로 컴퓨터를 사용하여 관련되는 특정값들을 구했고 이들과 인장실 험에서 얻은 용접강도와의 상관관계를 얻음으로써 과연 어떠한 공정변수가 용접품질을 잘 대변해 줄 수 있는가를 실험적으로 조사하였다.

Development of Microcomputer-Based On-Line Monitoring System of Spot Weld Quality (마이크로 컴퓨터를 이용한 온라인 점용접 품질 감시체제 개발에 관한 연구)

  • 김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.241-246
    • /
    • 1986
  • A new method of on-line monitoring of spot weld quality is proposed by analysing weld votage signal. Weld voltage signal has been modeled by autoregressive model which is suitable for on-line modeling scheme, and order of the model is determined by F-test. From the chosen model, strength. Upon experimental results, it has been shown that fundamental frequency dispersion of weld voltage can be used as a good parameter like maximum thermal expansion in on-line monitoring of spot weld quality. Microcomputer implementation of the proposed monitoring method is also developed and presented.

The Salt Removal Efficiency Characteristics of Carbon Electrodes Using Fabric Current Collector with High Tensile Strength in a Capacitive Deionization Process (인장강도가 뛰어난 직물집전체를 이용한 탄소전극의 축전식 탈염공정에서의 제염효과)

  • Seong, Du-Ri;Kim, Dae Su
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.466-473
    • /
    • 2020
  • Fabric current collector can be a promising electrode material for Capacitive Deionization (CDI) system that can achieve energy-efficient desalination of water. The one of the most attractive feature of the fabric current collector is its high tensile strength, which can be an alternative to the low mechanical strength of the graphite foil electrode. Another advantage is that the textile properties can easily make shapes by simple cutting, and the porosity and inter-fiber space which can assist facile flow of the aqueous medium. The fibers used in this study were made of woven structures using a spinning yarn using conductive LM fiber and carbon fiber, with tensile strength of 319 MPa, about 60 times stronger than graphite foil. The results were analyzed by measuring the salt removal efficiency by changing the viscosity of electrode slurry, adsorption voltage, flow rate of the aqueous medium, and concentration of the aqueous medium. Under the conditions of NaCl 200 mg/L, 20ml/min and adsorption voltage 1.5 V, salt removal efficiency of 43.9% in unit cells and 59.8% in modules stacked with 100 cells were shown, respectively. In unit cells, salt removal efficiency increases as the adsorption voltage increase to 1.3, 1.4 and 1.5 V. However, increasing to 1.6 and 1.7 V reduced salt removal efficiency. However, the 100-cell-stacked module showed a moderate increase in salt removal efficiency even at voltages above 1.5 V. The salt removal rate decreased when the flow rate of the feed was increased, and the salt removal rate decreased when the concentration of the feed was increased. This work shows that fabric current collector can be an alternative of a graphite foil.

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

A Study on the circuit design and measurement method for the measurement of active points on skin (피부 활성점 측정을 위한 회로설계 및 측정방법연구)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.713-718
    • /
    • 2020
  • The method of measuring skin active points is a technique for obtaining a lot of biometric information because it is measured with convenience, low cost and non-invasive methods. In this paper, we used in a three electrode measure method that has the advantage of measuring the impedance of the APs under the skin. The impedance measuring method is well illustrated by a simple model of an equivalent electrical circuit that correlates well with experimental results. The characteristic frequencies of APs are about 15-30HZ higher than that of surrounding skin and the values of measured reactance are about 35-77KΩ smaller. This technology analyzed accurately and objectively the reactance and characteristic frequency of APs and the surrounding skin using a non-invasive measuring system.

Development of the Quantum Dot/ZnO Nanowire Heterostructure and Their Photoelectrochemical Application

  • Hwang, In-Seong;Seol, Min-Su;Kim, Hui-Jin;Yong, Gi-Jung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.378-378
    • /
    • 2011
  • ZnO 나노선 구조는 나노선 구조를 통해 입사한 빛을 산란시켜 광흡수를 촉진시키고, 바닥 전극으로 바로 이어진 수직의 1차원 구조를 통해 전자가 빠르게 이동할 수 있으며, 넓은 표면적을 가지고 있는 등의 장점을 가지고 있어 오래전부터 광전소자에 이용되었다. 하지만 ZnO 물질 자체의 밴드갭 에너지가 3.2 eV로 비교적 큰 편이라 가시광 영역의 빛을 흡수, 이용하기 위해서는 작은 밴드갭을 가지는 광감응 물질이 필요하다. 본 연구에서는 저온의 수열합성법을 통해 합성한 ZnO 나노선 구조 상에 Cd 계열의 무기물 양자점을 증착하여 이종구조를 형성하는 방법을 개발하였다. 본 연구에서 사용한 양자점인 CdS와 CdSe는 벌크 밴드갭 에너지가 각각 2.3 eV, 1.7 eV로 가시광 영역의 빛을 흡수할 수 있으며, ZnO 나노선과 type-II 밴드구조를 가지기 때문에 전자-정공 분리 및 포집에 유리하다. 합성된 구조를 이용하여 photoelectrochemical 특성을 분석하였으며, 그 결과 양자점의 증착으로 광전류 생성이 향상됨을 확인하였다. 특히 ZnO 나노선 상에 CdS 양자점 증착 후 추가적으로 CdSe 양자점을 증착하여 다중접합 나노선 구조를 형성한 경우 광전류 생성이 가장 크게 향상된 결과를 확인하였다.

  • PDF

Micro Electrochemical Machining using Anodic Polarization Curve (양극분극곡선을 미용한 미세 전해가공)

  • 최영수;강성일;전종업;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.999-1002
    • /
    • 2002
  • In this research, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result. it was confirmed that anodic voltage curve could be used very effectively for determining the optimal condition of micro-ECM, and the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

  • PDF

Electroencephalogram and Telecommunications (뇌파와 통신)

  • Kim, Jeong-Hwan
    • Electronics and Telecommunications Trends
    • /
    • v.11 no.2 s.40
    • /
    • pp.31-43
    • /
    • 1996
  • 본 고에서는 인간이 사고와 행동을 할 때 뇌에서 자발적으로 방출되는 뇌파를 미래의 통신시스템 및 서비스에 이용하기 위한 전단계로서, $\alpha$, $\beta$, $\delta$, $\theta$, $\gamma$$\mu$파 등 뇌파의 종류 및 특성과 국제적으로 사용되고 있는 10-20 방식에 의한 뇌파측정점, 그리고 전극배치법에 대해 고찰해보고, 뇌파인식에 관한 최근 연구동향을 분석하였다.