• Title/Summary/Keyword: 점 전극

Search Result 259, Processing Time 0.025 seconds

An Estimation of the Efficiency and Satisfaction for EEG Practice Using the Training 10-20 Electrode System: A Questionnaire Survey (연습용 10-20 Electrode System을 이용한 뇌파검사 실습의 효율성과 만족도 평가)

  • Lee, Chang Hee;Kim, Dae Jin;Choi, Jeong Su;Lee, Jong-Woo;Lee, Min Woo;Cho, Jae Wook;Kim, Suhng Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.300-307
    • /
    • 2017
  • Electroencephalography (EEG) is distinct from other medical imaging tests in that it is a functional test that helps to diagnosis disorders related to the brain, such as epilepsy. The most important abilities for a medical technologist when performing an EEG are knowing the exact location of the electrode and recording the EEG wave clearly, except for artifacts. Although theoretical education and practical training are both included in the curriculum for improving these abilities, sufficient practical training has been lacking due to problems like expensive equipment and insufficient practical training time. We try to solve these issues by manufacturing the training 10-20 electrode system and by estimating the efficiency and satisfaction of the training 10-20 electrode system through a questionnaire. The time required for practical training using this system was $43.58{\pm}9.647min$, which proved to be efficient. The satisfaction score of participants who experienced curriculum practical training was improved from $7.21{\pm}2.285$ to $9.46{\pm}1.166$. Based on these findings, it is considered that practical training via the use of the training 10-20 electrode system will solve the problems, such as lack of equipment and insufficient practical training time. Nonetheless, to further improve the training 10-20 electrode system, it must overcome the limitations of developing a device capable of checking the actual brain waves and validating the exact location of electrode attachment.

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF

카드뮴 셀레나이드 양자점 기반의 역 구조 유기태양전지

  • Lee, Gyu-Seung;Sim, Jae-Ho;Yang, Hui-Yeon;Son, Dong-Ik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.337.2-337.2
    • /
    • 2016
  • 역 구조 유기태양전지는 가격이 저렴하고 우수한 경량성, 간단한 제조공정 그리고 휘어짐이 가능한 소자를 제작할 수 있는 것이 큰 장점이다. 또한, 광활성층과 전극 사이에 표면개질 물질을 도입하여 에너지장벽을 줄임으로써 소자 전반적인 전하수송을 증가시킬 수 있게 되었다. 나아가 용액공정과 저온 공정을 통해 유기 광전자소자의 roll-to-roll 대면적화 기술을 기반으로 가격대비 성능을 개선시켰다. 본 연구에서는 CdSe 또는 CdSe@ZnS 양자점을 표면개질 유기물질인 polyethylenimine ethoxylated (PEIE)에 정전기적 인력의 결합을 통한 양자점 단일층을 얻었고 이는 전기수송층, 광흡수층 그리고 표면플라즈몬 공명(Surface plasmon resornace)의 역할을 수행하게 되면서 태양전지 전반적인 성능 향상을 관찰 할 수 있었고 양자점 단일층으로 인해 20%가 증가된 에너지변환효율 얻었다. 또한 단일층으로 형성된 CdSe 또는 CdSe@ZnS 양자점 은 $F{\ddot{o}}rster$ resonance energy transfer (FRET) 메커니즘을 통해 PC60BM과 P3HT의 Photo luminescence 세기를 99% 감쇄시켰고, CdSe 양자점을 유기 광활성층인 PTB7:PC71BM에 적용하여 8.1%의 수치를 나타내었다.

  • PDF

Development of CdSe/CdS Quantum Dot Co-sensitized ZnO Nanowire Solar Cell

  • Seol, Min-Su;Kim, Hui-Jin;Kim, U-Seok;Yong, Gi-Jung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.369-369
    • /
    • 2011
  • 양자점 감응형 태양전지는 가시광 영역을 흡수, 이용할 수 있는 광감응 물질로 무기물 양자점을 사용하며, 이 경우 나노미터 크기의 무기물 양자점으로 인한 양자제한 효과 (quantum confinement effect)에 의해 양자점의 사이즈 조절 만으로 밴드갭을 조절할 수 있어 광학적 특성 조절이 용이하며, 하나의 광자를 흡수하여 두개 이상의 전자-정공쌍을 만들 수 있는 (multiple exciton generation) 가능성이 있어 기존 태양전지가 가지는 이론적 한계효율(Shockley-Queisser limit)을 뛰어넘을 수 있다. 본 연구에서는 양자점 및 염료 감응형 태양전지분야에서 가장 많이 사용되고 있는 TiO2 다공성 필름이 아닌, ZnO 나노선 구조를 이용하여 양자점 감응형 태양전지를 제작하였다. ZnO의 경우 TiO2보다 높은 전자이동도를 가지며, 나노선 구조가 바닥전극까지 수직 연결된 1차원의 전자전달경로를 제공하여 결과적으로 광전자 포집에 유리하다. 또한, CdS, CdSe 양자점을 동시에 사용하여 광흡수 범위를 가시광 전 영역으로 확장하였으며, 계단형 밴드구조를 통해 광전자-정공 분리 및 포집을 용이하게 하였다. 더 나아가 전해질의 조성, 나노선의 길이 등 다양한 부분을 조절하면서 각 변수가 소자의 효율에 미치는 영향을 관찰하였다.

  • PDF

Simulation of heat flow for rectangular electrodes (사각형 전극에서의 열유동 해석)

  • 신윤섭;박수웅;나석주
    • Journal of Welding and Joining
    • /
    • v.8 no.1
    • /
    • pp.62-69
    • /
    • 1990
  • Being focused on the recent studies that the fatigue strength of resistance spot weldmentes can be improved by using ellipsoidal weld nuggets, the voltage and temperature distribution in resistance spot weldments were simulated for the various rectangular electrodes which had the different aspect ratio of the contact area. Because the electrode shape was not axi-symmetric, the solution domain for simulation should be three dimensional. A series of experiments were carred out to verify the analytically obtained temperature distribution in the weldment. From the calculational and experimental results, it could be revealed that the nugget took the form of ellipsoid, while both results showed a considerable discrepancy for the high aspect ratio.

  • PDF

A study on the Characteristics of the Polymer Light Emitting Diode (Polymer Light Emitting Diode(PLED)의 특성에 관한 연구)

  • Moon, H.D.;Kim, H.Y.;Kwon, Y.H.;Kim, Y.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1082-1085
    • /
    • 2003
  • 본 연구에서는 고분자를 사용하여 만든 유기EL소자인 PLED (Polymer Light Emitting Diode)의 제조공정 변화에 따른 소자성능을 연구하였다. PLED의 제작은 크게 ITO 기판 제작, 발광층 및 전극 증착 등의 공정으로 나누어진다. ITO 기판은 사진식각공정으로, 발광층의 증착은 스핀코팅법으로, 전극은 진공증착법으로 각각 제작하였다. 코팅 시 스핀속도 및 점도 조절을 통하여 발광층의 두께를 조절하였고, 스핀코팅 후 건조방법에 따라서 표면의 uniformity와 발광특성을 비교해 보았다. 실험결과 특정 두께에서 발광특성이 우수하게 나타나는 것을 확인할 수 있었다. 그리고 건조방법에 따라 발광층의 표면 uniformity에 차이가 있었으며, 표면 uniformity에 따라 diode의 I-V 특성 경향이 달리 나타났다.

  • PDF

Preparation Pb free frit for Ag Paste in PDP application (PDP적용 Ag paste의 Pb free frit개발)

  • 김형수;최정철;최승철
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.101-103
    • /
    • 2002
  • PDP등의 각종 전자부품에 사용되는 Ag paste 의 frit은 주로 PbO를 주성분으로 하는 물질이 사용되어왔다. 그러나 이러한 Pb계 재료는 환경유해한물질로 규제대상이 되고 있다. 이에 대비하여 본 연구에서는 Bi$_2$O$_3$을 주성분으로 하여 B$_2$O$_3$, SiO$_2$, A1$_2$O$_3$가 함유된 새로운 frit을 개발하였다. TMA등을 이용하여 열적 특성을 관찰하였으며, 전극용 Ag-Paste를 제조한 후 스크린프린팅하여 인쇄성과 미세구조를 관찰하였고, 전기저항 및 소성두께를 측정하였다. 또한 전이온도, 연화점, 열팽창계수등을 조사하여 기존의 Pb함유 frit과 물성을 비교하였으며 PDP용 Ag전극에 적용하는 새로운 frit으로의 가능성을 검토하였다.

  • PDF

Noninvasive Monitoring of ion Energy Distribution in Plasma Etching (플라즈마 식각 공정 시 비 침투적 방법으로 이온에너지 분포 측정 연구)

  • Oh, Se-Jin;Chung, Chin-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2069-2071
    • /
    • 2005
  • 본 연구에서는 플라즈마 식각 공정 시 식자률, 선택비, wafer 손상등과 중요한 관련이 있는 이온 에너지 분포(IED)를 측정하기 위해서 챔버 내에 직접적으로 분석기를 설치하지 않고 챔버 외부에서 비 침투적(noninvasive)인 방법을 사용하여 측정하였다. 이 방범은 신호선 중 한 곳에 측정 점을 잡기 위한 연결 장치만 필요하며 그곳에서의 전안 신호와 전류 신호를 오실로스코프에서 측정한 후 미리 얻어진 챔버 구조 모델링 계수 등을 통해 실제 바이어스 전극에 걸리는 전압 및 전극에서 플라즈마로 흐르는 전류를 유추한다. 전압 및 전류측정값과 power balance와 particle balance를 적용하여 얻은 플라즈마 특성 상태 변수들을 사용하여 oscillating step sheath model을 기반으로 한 분석 프로그램을 통해 실시간 이온에너지 분포 결과를 얻었다. 실제 공정 시 바이어스 주파수 변화, 바이어스 파워 변화, 소스 파워변화 조건 등에 따른 이온 에너지 분포 측정 및 분석을 통해 비 침투적측정방법 적용의 가능성과 장점을 확인하였다.

  • PDF

Transparent Counter Electrode for Quantum Dot-Sensitized Solar Cells with Nanotube Electrodes (나노튜브 전극 기반 양자점 감응 태양전지 구현을 위한 투명한 상대전극)

  • Kim, Jae-Yup
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • Anodic oxidized $TiO_2$ nanotube arrays are promising materials for application in photoelectrochemical solar cells as the photoanode, because of their attractive properties including slow electron recombination rate, superior light scattering, and smooth electrolyte diffusion. However, because of the opacity of these nanotube electrodes, the back-side illumination is inevitable for the application in solar cells. Therefore, for the fabrication of solar cells with the anodic oxidized nanotube electrodes, it is required to develop efficient and transparent counter electrodes. Here, we demonstrate quantum dot-sensitized solar cells (QDSCs) based on the nanotube photoanode and transparent counter electrodes. The transparent counter electrodes based on Pt electrocatalysts were prepared by a simple thermal decomposition methods. The photovoltaic performances of QDSCs with nanotube photoanode were tested and optimized depending on the concentration of Pt precursor solutions for the preparation of counter electrodes.

Effect of Cathode Porosity on the Cathodic Polarization Behavior of Mixed Conducting LSCF(La0.6Sr0.4Co0.2Fe0.8O3) (혼합전도체 LSCF(La0.6Sr0.4Co0.2Fe0.8O3) 양극의 기공률에 따른 양극분극 특성)

  • Yun, Joong-Cheul;Lee, Jong-Ho;Kim, Joosun;Lee, Hae-Weon;Kim, Byong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.4
    • /
    • pp.251-259
    • /
    • 2005
  • In order to characterize the influence of the reaction-site density on the cathodic polarization property of LSCF, we chose the porosity of LSCF as a main controlling variable, which is supposed to be closely related with active sites for the cathode reaction. To control the porosity of cathodes, we changed the mixing ratio of fine and coarse LSCF powders. The porosity and pore perimeter of cathodes were quantitatively analyzed by image analysis. The electrochemical half cell test for the cathodic polarization was performed via 3-probe AC-impedance spectroscopy. According to the investigation, the reduction of oxygen at LSCF cathode was mainly controlled by following two rate determining steps; i) surface diffusion and/or ionic conduction of ionized oxygen through bulk LSCF phase, ii) charge transfer of oxygen ion at cathode/electrolyte interface. Moreover, the overall cathode polarization was diminished as the cathode porosity increased due to the increase of the active reaction sites in cathode layer.