• Title/Summary/Keyword: 점성 댐퍼

Search Result 46, Processing Time 0.023 seconds

Characteristics of Directional Squeeze Film Damper Using ER Fluid (ER유체를 이용한 이방성 스퀴즈필름 댐퍼의 특성)

  • 안영공;양보석;삼하신
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.301-306
    • /
    • 2001
  • Electro-Rheological (ER) fluid is applied to a controllable squeeze film damper (SFD) for stabilizing a flexibly supported rotor system. ER fluid is a class of functional fluid whose yield stress varies according to the applied electric field strength, which is observed as viscosity variation of the fluid. In applying ER fluid to a SFD, a pair of rings of the damper can be used as electrodes. When the electrodes are divided into a horizontal pair and a vertical one, the SFD can produce damping force in each direction independently. A prototype of the directionally controllable SFD was constructed and its performance was experimentally and numerically investigated in the present work.

  • PDF

Manufacturing of MR Dampers and Estimation of the Bingham Model Parameters (MR 댐퍼의 제작과 Bingham 모델의 매개변수 추정)

  • Lee, Gun-Myung;Park, Mun-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.82-87
    • /
    • 2014
  • Small MR dampers with a simple structure were designed and manufactured. The Bingham model was used to represent the dynamic characteristics of the damper, and the parameters of the model were estimated from experimental data which were obtained by harmonic tests. The value of the estimated yield shear force remains positive when no electric current is applied, and it increases slowly with the current. The estimated viscous damping coefficient has a value close to zero when no electric current is applied, and it increases almost linearly with the current.

Comparison of Performances refer to Magnetic and Fluid Analysis of Magneto-Rheological Flow Damper (자기점성유체 댐퍼의 자기장 및 유동 해석에 따른 성능비교)

  • Song, Jun-Han;Son, Sung-Wan;Lee, Gyu-Seop;Chun, Chong-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.98-102
    • /
    • 2009
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. To manufacture the magneto-rheological fluid damper that uses such characteristics of the fluid, a flow analysis of the inner damper was conducted to forecast the damper's capacity. In addition, using the finite element method software, analysis on the characteristics of electromagnetic field around the coil operation unit inside the damper. Based on the result of the analysis, a single core damper and a double core damper were built and tested for their dynamic function. Based on the result of the experiment, the propriety of the flow analysis was demonstrated, and the proposed model was verified.

  • PDF

Vibrational Properties of High Damping Polymer Concrete with Hybrid Damper (복합구조 댐퍼를 적용한 고 감쇠 폴리머 콘크리트의 진동 특성에 관한 연구)

  • Kim, Jeong-Jin;Choi, Kyung-Suk;We, Joon-Woo;Seok, Won-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.135-142
    • /
    • 2020
  • In the case of a concrete structure, vibration problems occur under various conditions because of its low damping performance. To solve this problem, a study on the high damping performance of the polymer concrete with hybrid damper has recently been increased. Since water is not used in polymer concrete, the curing time is short. Also, the physical properties and dynamic properties of polymer concrete are quite excellent. So polymer concrete is widely expected to be used for structural materials. The hybrid damper is the structural system that consists of steel balls and viscous fluid inside the pipe which is embedded in polymer concrete. It can reduce the structural vibrations through the energy dissipation mechanism of viscous fluid and steel balls. In this study, the physical and dynamic properties of polymer concrete with hybrid damper were compared with ordinary concrete. As a result, the elasticity coefficient and the strength of the polymer concrete with hybrid damper were so much excellent. In particular, the tensile strength was 6.5 to 10 times higher than ordinary concrete. The frequency response function and damping ratio were also compared. As a result, the dynamic Stiffness of the polymer concrete was 25% greater than that of ordinary concrete. The damping ratio of the polymer concrete was approximately 3 times higher than that of ordinary concrete. Although the dynamic stiffness of the hybrid damper showed similar tendency, the damping ratio was 3.5 times higher than that of ordinary concrete. Therefore, the polymer concrete with hybrid damper was superior to ordinary concrete.

Design and Performance Evaluation of Spring-viscous Damper for Torsional Vibration (스프링-점성형 비틀림 진동댐퍼 설계 및 성능 평가에 관한 연구)

  • Lee, D.H.;Chung, T.Y.;Kim, Y.C.;Kim, H.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1192-1198
    • /
    • 2011
  • Design routines of a torsional spring-viscous damper for a 1800 kW four cycle diesel engine-generator system are described. Modal techniques for system normalization and optimal equations for damper design are used to obtain proper design parameters of the damper. A prototype damper is manufactured according to the described design process and its two design parameters, stiffness and damping, are evaluated experimentally by torsional actuator test and free decay test. Experimentally obtained values of stiffness and damping coefficients showed good agreements with the designed values of the prototype damper.

Dynamic Characteristics of Eddy Current Damper (와전류 댐퍼의 동적특성)

  • Kwag, Dong-Gi;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.947-951
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force thus and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require the damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

  • PDF

The Study of Dynamic Characteristic of a Viscous Fluid Damper in Vibration Isolation (진동 방지용 점성 유체 댐퍼의 동특성 해석에 관한 연구)

  • 권오병;이강민;김유민;고철수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1136-1140
    • /
    • 2001
  • Viscous fluid damper is used for vibration isolation of piping system, presses, turbo-generator and other heavy industrial equipments, as well as seismic isolation of buildings structure. So dynamic characteristic of viscous fluid damper is very important. This paper presents the result of the study of dynamic characteristic of viscous fluid damper. And the force-displacement relation of the viscous damper is described by experimentally calibrated fractional derivative Maxwell Model. The proposed model is validated by dynamic testing and A good agreement between predicted and experimental results is obtained.

  • PDF

Study on the Parameter Decision of Spring-viscous Dampers for Torsional Vibration Reduction of Diesel Engine Shafting System (디젤엔진축계 진동저감을 위한 스프링-점성 댐퍼의 매개변수 결정 연구)

  • Lee, D.H.;Chung, T.Y.;Kim, Y.C.;Shin, Y.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1168-1175
    • /
    • 2010
  • Excessive torsional vibrations from marine engine shafting systems can be reduced by using torsional vibration dampers. But in order to be tuned effectively, the dampers should be designed through the optimum design procedure. In this paper, the procedure to get the optimum values of system parameters of spring-viscous dampers using effective modal mass of inertia and stiffness is suggested and the damping is determined by the exact algebra optimization method. The validity of the suggested method is confirmed through the application to a 1800 kW four cycle diesel engine and generator system.

Befitting Test of Magnetic Fluid to Speaker Damper (자성유체의 스피커 댐핑효과에 관하여)

  • 이효숙;유제광
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.2
    • /
    • pp.93-98
    • /
    • 1998
  • Magnetic fluids have been used in the commercial area, e. g damping, sealing and hydrodynamic bearing. In this study, magnetic fluid was made for damping in loudspeaker. The magnetic fluids were snthesized by dispersing the magnetite powder which was obtained by precipitation method in Yubase oil. When the magnetic fluid was applied to a 6 cm tweeter, improvements of damping, centering and heat transger in a loudspeaker were noted. Also we compared the performance of the magnetic fluid with 20 % magnetite in the oil and the one of APG-815 (Niphon Ferrofluidic Co.)

  • PDF