• Title/Summary/Keyword: 점검항목

Search Result 306, Processing Time 0.03 seconds

A Design and Implementation of the Lift Safety Inspection System using Android Smart Phone (안드로이드기반 스마트폰을 이용한 승강기 안전진단 시스템 설계 및 구현)

  • Choi, Sung-Hyun;Kim, Jong-Soo;Kim, Tai-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.113-118
    • /
    • 2012
  • This thesis suggests how to design and implement an Android smart phone application which can perform self check or safety inspection of lifts effectively. The safety checks of lifts go in the way that inspectors check the lifts' conditions generally and record manually following a form at the moment. This thesis analyses lift maintenance industry and introduces how to design a system to proceed effective self check using a smart phone with Android OS. By using a smart phone to check lifts, we can have advantages to improve the quality of self check and maintain careers establishing information database about safety items.

A Study on Inspecting Position Accuracy of DACS Pintle (위치자세제어장치의 핀틀 위치정확도 점검 방안 연구)

  • Tak, Jun Mo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.57-64
    • /
    • 2021
  • In the study, to minimize the error on guided control of the KV (Kill Vehicle) and to secure the hit-to-kill performance, a position accuracy inspection for the DACS (Divert and Attitude Control System) actuation system was proposed. The accuracy performance of the DACS actuation system is one of the most important factors in the interception of ballistic missiles. In order to validate actuation control accuracy of DACS system, an inspection item was set for position accuracy, and the inspection system was designed for DACS pintle. To measure the absolute position value of the DACS pintle, an external measurement system was developed using laser displacement sensors. The inspection system was designed so that it can be compared with the actuation command in real time. The proposed position accuracy inspection system can be inspected not only in a DACS system but also in missile system level. The position accuracy inspection was performed using the designed inspection system, and analysis of the inspection result.

Proposal of Security Inspection Procedure for Linux System (리눅스 시스템을 위한 보안점검 항목 및 절차 제안)

  • Yu, Jun-sang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.601-602
    • /
    • 2009
  • 최근 기업 및 관공서 등에서 비용대비 효과적인 Linux System을 적극 도입하면서 그 관리와 보안사항이 이슈화되고 있다. 본고는 현업의 관리자들이 손쉽게 적용할 수 있는 시스템 보안점검 절차 및 사고 발생시 보안프로그램을 이용한 대응 방법에 대해 제안하고자 한다.

A Study on the Improvement of Daily Inspection for the Safety of University Laboratory - Based on Delphi surney - (대학 연구실 안전을 위한 일상점검 개선방안에 관한 연구 - 델파이 조사를 기반으로 -)

  • Choi, Youn-Woo;Lee, yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.38-48
    • /
    • 2019
  • The purpose of this study is to present a more effective daily checklist than the formal routine check before the experiment to prevent accidents in the university laboratory. To do this, we reconstructed the current daily checklist and previous research data and conducted a second Delphi survey. As a result, there were four general safeties such as arranging the laboratory, three mechanical safeties such as abnormal condition of machine and tool tightening parts, three electric safeties such as prohibition of loading around the electric distribution panel, six chemical safeties such as handling and managing harmful factors, three items of fire safety such as fire extinguisher inspection, five cases of gas safety gas container inspection, one item of biological safety such as the state of hand sterilizer management and one other item, which were provided in the daily checklist as twenty six categories in total. According to the opinions of related experts, it is necessary to have an easy and simplified daily checklist for actual daily checkups.

Improvement Mechanism for Automatic Web Vulnerability Diagnosis (웹취약점 자동진단 개선방안)

  • Kim, Tae-Seop;Jo, In-June
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.2
    • /
    • pp.125-134
    • /
    • 2022
  • Due to the development of smartphone technology, as of 2020, 91.9% of people use the Internet[1] to frequently acquire information through websites and mobile apps. As the number of homepages in charge of providing information is increasing every year, the number of applications for web vulnerability diagnosis, which diagnoses the safety of homepages, is also increasing. In the existing web vulnerability check, the number of diagnostic personnel should increase in proportion to the number of homepages that need diagnosis because the diagnosticians manually test the homepages for vulnerabilities. In reality, however, there is a limit to securing a web vulnerability diagnosis manpower, and if the number of diagnosis manpower is increased, a lot of costs are incurred. To solve these problems, an automatic diagnosis tool is used to replace a part of the manual diagnosis. This paper explores a new method to expand the current automatic diagnosis range. In other words, automatic diagnosis possible items were derived by analyzing the impact of web vulnerability diagnosis items. Furthermore, automatic diagnosis identified possible items through comparative analysis of diagnosis results by performing manual and automatic diagnosis on the website in operation. In addition, it is possible to replace manual diagnosis for possible items, but not all vulnerability items, through the improvement of automatic diagnosis tools. This paper will explore some suggestions that can help improve plans to support and implement automatic diagnosis. Through this, it will be possible to contribute to the creation of a safe website operating environment by focusing on the parts that require precise diagnosis.

Performance Evaluation Method for Facility Inspection and Diagnostic Technologies (첨단기술을 활용한 시설물 점검 및 진단 기술 검·인증을 위한 성능평가 방법론)

  • Lee, Young-Ho;Bae, Sung-Jae;Jung, Wook;Cho, Jae-Yong;Hong, Sung-Ho;Nam, Woo-Suk;Kim, Young-Min;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.178-191
    • /
    • 2020
  • Purpose: This paper proposes a performance evaluation method for state-of-the-art facility inspection/diagnostic equipment through a trend survey of equipment and standardization systems of US, Japan, and Korea. This paper also suggests the priority of developing a performance evaluation method through expert interviews and surveys. Method: In this study, report for the last 5 years of FMS, state-of-the-art equipment of facility maintenance companies/safety diagnosis specialist agencies and papers/research reports/patents of NTIS were analyzed to identify recent trends of facility inspection/diagnostic equipment usages. standardization system of US, Japan, and Korea were analyzed to figure out a suitable form of a performance evaluation method for the domestic situation. And expert interview and survey were conducted to identify the priority of developing a performance evaluation method. Result: The performance evaluation method must be developed by the shape that only evaluates performance, regardless of types of equipment, on inspection item level for creative technology development. The priority of developing the performance evaluation method was identified as crack detection of concrete for durability evaluation and displacement/deformation/fatigue detection of concrete and steel for stability evaluation. Conclusion: The performance evaluation method will be developed firstly for the crack detection of concrete for durability evaluation and displacement/deformation/fatigue detection of concrete/steel for stability evaluation. In order to promote creative technology development, the performance evaluation method should be developed in a form that provides standardized specimens or testbeds and can be applied regardless of types of technologies.

Aging Deterioration for Electric Power Transmission Tower on Offshore Through Periodic Inspections (해상송전철탑 구조물의 주기점검을 통한 경년열화 변화특성)

  • Lee, Ho Beom;Jang, Il Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.25-33
    • /
    • 2012
  • In electric power transmission tower structures on offshore, implementation of life management using the event data of regular safety inspections for structural and material damages is strongly recommended. In this study, six tower structures in Sihwa Lake around Yeoungheung island were target bodies for the safety inspections. safety inspections for deterioration about each of six towers were performed about three items for steel member, five items for concrete foundation, and four items for steel-pipe pile in seawater and seawater itself. Safety inspections for steel members included the visual observations of surface appearances, the measurements of member thicknesses, and the checks of painting states. Also safety inspections for concrete foundations comprised the estimation of crack features, the evaluation of non-destructive compression strengths, and the measurements of neutralization depths and chlorides contents. For steel-pipe piles in seawater the inspections comprised the surveys of corrosion states in accordance with potential levels tests and anode tests, the analyses of photos taken on surfaces of the piles as well as the evaluation of seawater quality. A set of deterioration inspections was performed at the same positions around october of each year for three consecutive years. As a result in this study, Newly developed deterioration indexes have been applied profitably to maintain structural safety for electric power transmission towers by utilizing these event data systematically.

The Model of Information System Operating Audit for the Service Level Agreement (서비스 수준 협약에 따른 정보시스템 운영감리 모형)

  • Lee, Sung-Ho;Choi, Jin-Tak;Kim, Dong-Soo;Kim, Hee-Wan
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.71-82
    • /
    • 2012
  • The interest in SLA in accordance with the development of IT outsourcing has increased due to the rapid development of information systems. Moreover, an awareness and necessity for the Information System Operating Audit has increased while an effective IT service management operations for information systems is needed desperately. However, information system operations and maintenance instructions of the National Information Society Agency operates due to the current information system operation, but the experience and the interpretation of the auditor determine the decision in the field. This paper introduces an operating audit model for the efficient management. This model is derived from the Korea Information Society Agency's operating instructions of the Information Systems Audit and their inspection services. The audit checklists were derived from the areas of service planning, service delivery, service support, and service management. Consequently, the operating audit model was proposed, and the suitability of this model was verified by experts' opinions on the survey.

A Study on the System and Operation of Laboratory Safety Inspection and Diagnosis (연구실 안전점검 및 정밀안전진단제도 개선에 관한 연구)

  • Woo, In-Sung;Hwang, Myung-Hwan;Lee, Hong-Ju
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.2
    • /
    • pp.45-54
    • /
    • 2019
  • According to the Laboratory Safety Act, each laboratory in the field of science and technology must conduct safety inspections and diagnosis every year or every two years. At present, the relevant guidelines are not clear, so there is a high possibility that inspection and diagnosis will become ineffective. In the laboratory, there is a pre-risk factor analysis system for hazardous factors, but there are many difficulties in implementation due to lack of education and understanding of the researchers, excessive work, etc. For the analysis of the opinions of experts in the safety field using the Delphi technique, we analyzed the following items: 1. Consideration in applying the Lab Safety Act, 2. Consideration in Lab Safety inspection and diagnosis, and 3. Government policy necessary for Lab. safety. Through the investigation and analysis of the detailed items, we extracted for problems and alternatives in current laboratory safety diagnosis and current law.

Database Construction Plan of Infrastructure Safety Inspection and In-depth Inspection Results (사회기반 시설물의 안전점검 및 정밀안전진단결과 DB 구축방안 연구)

  • Ryu, Jong Mo;Shin, Eun Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.133-141
    • /
    • 2014
  • This study was carried out to establish the database system by using the safety inspection and in-depth inspection results for infrastructures such as bridges, tunnels, dams, and water supplies. A classification system of each facility was proposed by standardizing items for inspection & diagnosis in order to automatize work process. Also, it justifies data structure based on database from pre-investigation to field survey, evaluation of facilities, and report making. In addition to this, it suggests improvement plans of relative regulations and guidelines such as Facility Management System(FMS), operational regulation, and inspection detailed guideline to make inspection result database of infrastructures which can be used effectively.