• Title/Summary/Keyword: 절연특성

Search Result 2,141, Processing Time 0.027 seconds

A Study on Behaviour and Characteristics of Spark Discharge in Spark Ignition System (스파크 점화 시스템의 방전 거동 및 특성에 관한 연구)

  • Lee Myung Jun;Hall Matt;Ezekoye Ofodike A.;Matthews Ron;Chung Sung Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.100-108
    • /
    • 2006
  • Time-resolved current and voltage measurements for an inductive automotive spark system were made. Also presented are measurements of the total energy delivered to the spark gap. The measurements were made in air for a range of pressures from 1-18atm, at ambient temperatures. The measured voltage and current characteristics were found to be a function of many ignition parameters; some of these include: spark gap distance, internal resistance of the spark plug and high tension wire, and pressure. The voltages presented were measured either at the top of the spark plug or at the spark gap. The measurements were made at different time resolutions to more accurately resolve the voltage and current behavior throughout the discharge process. This was necessary because the breakdown event occurs on a time scale much shorter than the arc and glow phases. The breakdown, are, and glow voltages were found to be functions of spark plug resistance, gas density, and spark plug gap as expected from the literature. Spark duration was found to decrease as either pressure or gap was increased. The transition from the arc to glow phase is usually distinguished by a sudden rise in the voltage across the gap. At pressures above about 7atm this transition was not observed suggesting that a glow phase was not present. Energy delivered to the gap increased with increasing pressure. The effective resistance of the spark gap during discharge was about twice as large for the glow phase as the arc phase.

An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged ($CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구)

  • 이수경;김종훈;김영진;최종운
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.19-26
    • /
    • 1999
  • $CO_2$ extinguishing system is the most $\phi$pular among the gas extinguishing system. $CO_2$ is usually stored with liquified state. But, it gasifies at the tip of nozzle when $CO_2$ was released through the pipe and head. A ro$\alpha$n temperature is very low when $CO_2$ was released. So electrical instrument, magnetic storage equipment and memory semiconductor are electrically or physically injured by cooling effect in a few minutes. So, we intend to find out temperature profile and electrical damage in compartment area, and supply basic d data for research and making standards and code through the full scale experiment. As result of experiment on the damage due to cooling effect from $CO_2$ extinguishing system, i instantaneous discharging temperature. was $-82.5^{\circ}C$ in average. An average temp. in the compartment after discharging $CO_2$ was $-40^{\circ}C$.

  • PDF

Property Comparison of Ru-Zr Alloy Metal Gate Electrode on ZrO2 and SiO2 (ZrO2와 SiO2 절연막에 따른 Ru-Zr 금속 게이트 전극의 특성 비교)

  • Seo, Hyun-Sang;Lee, Jeong-Min;Son, Ki-Min;Hong, Shin-Nam;Lee, In-Gyu;Song, Yo-Seung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.808-812
    • /
    • 2006
  • In this dissertation, Ru-Zr metal gate electrode deposited on two kinds of dielectric were formed for MOS capacitor. Sample co-sputtering method was used as a alloy deposition method. Various atomic composition was achieved when metal film was deposited by controlling sputtering power. To study the characteristics of metal gate electrode, C-V(capacitance-voltage) and I-V(current-voltage) measurements were performed. Work function and equivalent oxide thickness were extracted from C-V curves by using NCSU(North Carolina State University) quantum model. After the annealing at various temperature, thermal/chemical stability was verified by measuring the variation of effective oxide thickness and work function. This dissertation verified that Ru-Zr gate electrodes deposited on $SiO_{2}\;and\;ZrO_{2}$ have compatible work functions for NMOS at the specified atomic composition and this metal alloys are thermally stable. Ru-Zr metal gate electrode deposited on $SiO_{2}\;and\;ZrO_{2}$ exhibit low sheet resistance and this values were varied with temperature. Metal alloy deposited on two kinds of dielectric proposed in this dissertation will be used in company with high-k dielectric replacing polysilicon and will lead improvement of CMOS properties.

Adhesion properties and Breakdown behaviors of LSR Interface (LSR 계면의 접착특성 및 절연파괴거동)

  • Yoon, Seung-Hoon;Nam, Jin-Ho;Lee, Gun-Ju;Choi, Soo-Geol;Shin, Doo-Sung;Ji, Eung-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

Embedded Inductors in MCM-D for RF Appliction (RF용 MCM-D 기판 내장형 인덕터)

  • 주철원;박성수;백규하;이희태;김성진;송민규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.31-36
    • /
    • 2000
  • We developed embedded inductors in MCM-D substrate for RF applications. The increasing demand for high density packaging was the driving forces to the development of MCM-D technology. Most of these development efforts have been focused on high performance digital circuits. However, recently there is a great need fur mixed mode circuits with a combination of digital, analog and microwave devices. Mixed mode modules often have a large number of passive components that are connected to a small number of active devices. Integration of passive components into the high density MCM substrate becomes desirable to further reduce cost, size, and weight of electronic systems while improving their performance and reliability. The proposed MCM-D substrate was based on Cu/photosensitive BCB multilayer and Ti/Cu is used to form the interconnect layer. Seed metal was formed with 1000 $\AA$ Ti/3000 $\AA$ Cu by sputtering method and main metal was formed with 3 $\mu\textrm{m}$ Cu by electrical plating method. The multi-turn sprial inductors were designed in coplanar fashion. This paper describe the manufacturing process of integrated inductors in MCM-D substrate and the results of electrical performance test.

  • PDF

Magnetic Micro-Deflector for a Microcolumn System (초소형 전자칼럼을 위한 마이크로 자기장 디플렉터 연구)

  • Kim, Young-Chul;Kim, Dae-Wook;Ahn, Seung-Joon;Kim, Ho-Seob;Park, Seong-Soon;Park, Kyoung-Wan;Hwang, Nam-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.426-431
    • /
    • 2007
  • We have fabricated a magnetic micro-deflector for a microcolumn system and tested its performance by operating it in the low energy region. The micro-deflector is composed of Cu coils around cylindrical cores with $500{\mu}m$ diameter. The diameter of the Cu coil itself is $100{\mu}m$. Two pairs of deflectors designed for a 2-dimensional scan, that is X and Y deflection, are fixed on an insulating plate. The low power performance of a magnetic micro-deflector attached to a microcolumn system has been tested and the magnitude of deflection is measured to be ${\sim}100{\mu}m/A$, which offers the possibility for practical applications of the magnetic micro-deflector.

Characteristics of Radiated Electromagnetic Waves with Partial Discharge Propagation in Model GIS Being Insulation Particle (모의 GIS 내부에 유전체 파티클 존재시 부분방전 진전에 따른 방사전자파의 특성)

  • Park, Kwang-Seo;Kim, Lee-Kook;Kim, Jong-Wan;Ju, Je-Hyun;Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.69-76
    • /
    • 2005
  • In this paper partial discharge were simulated by insulation particle which could be easy accumulated charge and concentrated electric field in the model GIS. In this times this paper measured and analyzed the radiated electromagnetic waves by using spectrum analyzer and antenna$(30\~2000(MHz))$ for measurement of$ EMI{\cdot}EMC$ in accordance with occurrence and propagation of partial discharge. This paper suggested the other method of detecting and estimating of partial discharge for insulation diagnosis of GIS being insulation particle by measurement and analysis of radiated electromagnetic waves. From results of this study, it was confirmed that if the suggested method should be used for the diagnosis of insulation in the model GIS being insulation particle, detecting partial discharge and estimating discharge propagation will be possible.

A Study on Electrostatic Electrification Relaxation Properties of Glass Filament for Insulation (절연용 유리장섬유의 정전기 대전완화 특성에 관한 연구)

  • Lee, Sung Ill;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.837-842
    • /
    • 2015
  • In this study, the characteristics of electrostatic attenuation in plain shape glass filament sample (0.29 mm thickness, cross section of $12.25cm^2$, $16cm^2$, $20.25cm^2$) for insulator has been measured at temperature of $5^{\circ}C{\sim}38^{\circ}C$, humidity of 50%~90%. The results of this study are as follows. In case of samples that the cross section is $12.25cm^2$, $16cm^2$, $20.25cm^2$ at humidity of 50%~90%, it found that the electrification voltage of electrostatic increased with increasing temperature, with a return to decrease at $20^{\circ}C$. In case of samples that the cross section is $12.25cm^2$, $16cm^2$, $20.25cm^2$ at temperature of $5^{\circ}C{\sim}38^{\circ}C$, it found that the electrification voltage of electrostatic decreased with increasing humidity. In case of the sample at temperature of $20^{\circ}C$ and humidity of 65%, 75%, it found that the electrification voltage of electrostatic increased with increasing cross section. In case of the sample at humidity of 65% and cross section of $12.25cm^2$, the time that it takes to reduce electrification voltage of electrostatic in half decreased to 0.912s, 0.736s, 0.673s with increasing temperature to $10^{\circ}C$ $20^{\circ}C$, $30^{\circ}C$.

A Study of Particle-Initiated Breakdown Characteristics on a Spacer Surface for $SF_6$ GIS ($SF_6$ GIS용 스페이서 표면에서의 파티클에 의한 절연파괴 특성연구)

  • Kim, Jae-Ho;Lee, Yong-Gil;Kim, Dong-Eui;Lee, Sae-Hun;Kim, Jung-Dal
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1536-1539
    • /
    • 1994
  • The influence due to metallic particle contaminated on spacer surface is remarkable in the decreasing of dielectric strength in $SF_6$ GIS. In relation with this problem, We studied, AC flash-over voltage characteristics and breakdown mechanism are investigated under metallic particle initiated condition in $SF_6$ gas by varying the particle position, particle shape with a plane-plane electrode. The main results arc as follows 1. The small amount of the metallic particle in the gap do not make flash-over voltage to be influence, but the significant decrease of th flash-overed voltage is result in case of the big and long size of the metallic paraticle. 2. Influence of the flash-over voltage are lowest in the mid and are highest in the electrode of metallic particle position. 3. In case of the initiated metallie particle, The more the pressure are high, the more the recluced ratio of flash-over voltage are high. 4. The metallic particle shape which results in the reduced flash-over voltage forced the critical pressure to move in to the region of low pressure. 5. The existance of the metallic particle on the upper electrode side and high pressure make the decreasing ratio of flash-over voltage bigger than that of the ground side electrode.

  • PDF

The TiO2 based electrode consisting binary catalysts which is prepared by anodization for water oxidation application (양극산화법을 통해 제조한 IrO2-RuO2 촉매를 포함하는 고성능 수전해 산소발생용 TiO2 나노튜브 전극)

  • Yu, Hyeon-Seok;O, Gi-Seok;Lee, Gi-Baek;Choe, Jin-Seop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.191.2-191.2
    • /
    • 2016
  • $TiO_2$는 우수한 화학적 및 물리적 안정성 때문에 수전해 장기간 사용에 적합한 전기화학 전극으로 여겨진다. 큰 표면적을 갖는 $TiO_2$를 제조하기 위한 수많은 방법 중 양극산화(anodization)는 비교적 간단하고 저렴한 공정으로 인하여 매우 실용적인 방법으로서 알려져 있다. 특히, 고도로 정렬 된 $TiO_2$ 나노튜브($TiO_2$ NTs) 의 경우에는 분말상과 달리 전극제조를 위해 추가적인 접착제를 필요하지 않다. 그러나, $TiO_2$는 일반적으로 절연 특성을 나타내기 때문에 전극의 활용을 위해서는 본질적으로 촉매의 사용이 불가피하다. 다수의 전기 촉매 중, $IrO_2$$RuO_2$는 수전해 분야에 잘 알려진 산화 촉매이다. 그럼에도 불구하고, 특유의 높은 종횡비 때문에 $TiO_2$ 나노튜브에 전기 촉매를 균일하게 도핑하는 것은 많은 어려움이 따른다. 이를 해결하기 위한 방법으로 $RuO_2$를 도핑하기 위한 단일공정 $TiO_2$ 양극산화 기술이 보고된 바 있다. 본 연구에서는 2원 촉매($IrO_2$$RuO_2$)를 $TiO_2$ 나노튜브에 도핑하기 위한 단일공정 양극산화 기술에 대하여 연구하였다. 전구물질로써 $KRuO_4$($RuO_2$ 전구체)와 IrOx 나노입자(IrOx NPs, $IrO_2$ 전구체)를 사용하였다. 특히, IrOx를 나노 입자는 $IrCl_3$로부터 중간 매체로 합성된다. IrOx는 단일공정 양극산화 중에 $TiO_2$ 나노튜브 상에 도핑 가능한 이온 형태인 $IrO_4$-로 전환될 수 있다. 제조된 시료는 열처리 후 바로 전극으로 사용되었으며 SEM, XPS, TEM, ICP-OES 등으로 정성, 정량 분석을 수행하였다. LSV와 EIS를 통해 전기화학적 성능 평가가 이루어졌으며, LSV를 통해 포집한 기체는 가스 크로마토그래피를 사용하여 정량분석한 후 그 효율을 측정하였다.

  • PDF