• Title/Summary/Keyword: 절대교정

Search Result 55, Processing Time 0.026 seconds

Development of an Apparatus for In-situ Vacuum Gauge Calibration (In-situ 진공게이지 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Jho, M.J.;Chung, W.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.605-611
    • /
    • 2006
  • We have developed in-situ vacuum gauge calibration system in the range 1 Pa to 100 kPa by using constant volume method. The system is capable of gauge calibration by comparison method without demount the reference gauges. The system will be useful for dissemination of national vacuum standards to foreign developing countries and domestic industries.

Calibration System for Angular Vibration Using Precision Rotary Encoder (고정밀 회전엔코더를 이용한 회전진동 교정시스템)

  • Nam, Seunghwan;Baik, Kyungmin;Cheung, Wan-Sup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • In this paper, two calibration methods for angular vibration pickups using a precision rotary encoder are proposed. The KRISS (Korea Research Institute of Standards and Science) primary angular vibration calibration system and the calibration procedures are briefly explained. The rotary encoder is shown to be calibrated in two methods: The one is to use the laser interferometer to calibrate the rotary encoder under test and the other is to exploit the certificate of the encoder supplied. Complex sensitivities measured from the first are shown to be less than 0.1 % difference in magnitude and $0.01^{\circ}$ difference in phase shift in reference to those of the primary calibration system. Their expanded uncertainties were observed to be less than 0.6 % in magnitude and $0.4^{\circ}$ in phase shift over the range of 0.4 to 200 Hz. Under the same calibration conditions, complex sensitivities evaluated by the second method are shown be 0.1 % difference in magnitude and $0.6^{\circ}$ difference in phase shift in reference to those of the primary calibration system. Their expanded uncertainties were seen to be less than 4.8 % in magnitude and $2.8^{\circ}$ in phase shift.

Automation of Primary Vibration Calibration System Using Laser Interferometer (레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화)

  • Cho, Seung-Il;Lee, Yong-Bong;Jeon, Byeong-Su;Lee, Jong-Kyu;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

Primary vibration calibration by laser interferometry (레이저 간섭계를 이용한 진동 가속도계의 절대교정)

  • 이두희;이용봉;전병수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1356-1360
    • /
    • 2001
  • A number of calibration methods are described in ISO 16063 (revision of ISO 5347) and they may be used for special purposes. However, the use of a laser interferometer is recommended for primary calibration. This paper introduces the primary vibration calibration by measuring displacement amplitude and frequency using laser interferometry.

  • PDF

Realization of a detector-based Candela scale traceable to the absolute cryogenic radiometer (절대 극저온 복사계에 소급된 검출기 기반 칸델라 눈금의 실현)

  • 박승남;이동훈;김용완;정영붕;이인원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.280-281
    • /
    • 2003
  • 광도 측정의 기본단위인 칸델라 눈금을 확립하는 방법에는 흑체에서 방출되는 분광복사휘도를 기준으로 사용하는 광원 기반 방법과 극저온 절대 복사계(absolute cryogenic radiometer; ACR)로 부터 출발하여 실현하는 검출기 기반의 두 가지 방법이 사용된다. ACR를 사용하면서 검출기 기반 칸델라 눈금의 불확도가 흑체의 온도 측정 불확도로부터 전파되는 불확도 보다 휠씬 작기 때문에 각국의 국가 측정 표준 대표기관에서 검출기 기반 칸텔라 눈금을 실현하고, 교정이나 측정 서비스를 제공하고 있다. (중략)

  • PDF

Analysis and Forecasting of Daily Bulk Shipping Freight Rates Using Error Correction Models (오차교정모형을 활용한 일간 벌크선 해상운임 분석과 예측)

  • Ko, Byoung-Wook
    • Journal of Korea Port Economic Association
    • /
    • v.39 no.2
    • /
    • pp.129-141
    • /
    • 2023
  • This study analyzes the dynamic characteristics of daily freight rates of dry bulk and tanker shipping markets and their forecasting accuracy by using the error correction models. In order to calculate the error terms from the co-integrated time series, this study uses the common stochastic trend model (CSTM model) and vector error correction model (VECM model). First, the error correction model using the error term from the CSTM model yields more appropriate results of adjustment speed coefficient than one using the error term from the VECM model. Furthermore, according to the adjusted determination coefficients (adjR2), the error correction model of CSTM-model error term shows more model fitness than that of VECM-model error term. Second, according to the criteria of mean absolute error (MAE) and mean absolute scaled error (MASE) which measure the forecasting accuracy, the results show that the error correction model with CSTM-model error term produces more accurate forecasts than that of VECM-model error term in the 12 cases among the total 15 cases. This study proposes the analysis and forecast tasks 1) using both of the CSTM-model and VECM-model error terms at the same time and 2) incorporating additional data of commodity and energy markets, and 3) differentiating the adjustment speed coefficients based the sign of the error term as the future research topics.

The use of miniscrew as an anchorage for the orthodontic tooth movement (Miniscrew를 고정원으로 이용한 교정치료)

  • Kyung, Seung-Hyun;Lim, Jung-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.415-424
    • /
    • 2001
  • Anchorage in orthodontics is very important factor for orthodontist to treat malocclusion from diagnosis and treatment planning to end of treatment. Skeletal anchorage like miniscrew is supposed to be more effective method in anchorage control than conventional anchorage which needs patient's good cooperation. So this article will be mentioned about various clinical application of miniscrew through the general investigation and case reports about orthodontic use of miniscrew, specially about screwing area and clinical consideration of miniscrew's screwing on midpalate. The changes of treatment philosophy and methods by using skeletal anchorage were summarized and following results were obtained. 1. The orthodontic anchorage changed from relative concept to absolute one. 2. Bodily movement of teeth gets easier and determinate force system is possible on biomechanical consideration. 3. Some part of treatment that needs surgical intervention is possible by just orthodontic treatment.

  • PDF

New calibration apparatus for a precise barometer (초정밀 기압계 교정을 위한 새로운 압력계 교정장치 개발)

  • 우삼용;이용재;최인묵;김부식;최종운
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.157-161
    • /
    • 2003
  • Nowadays there are increasing demands for more accurate measurement of atmospheric pressure according to the development of environmental industries. One of the most important pressure gauges for satisfying these demands is a quartz resonance barometer. In order to calibrate such an accurate barometer, laser/ultrasonic mercury manometers have been used. However, complexity and cost of mercury manometers made it out of use gradually. As a substitute, a gas-operated pressure balance is used for calibration of precise barometers. In such a case, commercially available pressure balances cannot be entirely suitable because consequent exposure of the piston, cylinder and masses to the atmosphere causes the problem of contamination. In this paper a device for changing the masses in situ without breaking the vacuum is described. This device made it possible to add or remove weights in the absolute mode, thereby greatly reducing the time between observations. At the same time, we investigated the characteristics of a commercial precise barometer using this new apparatus.