• Title/Summary/Keyword: 절단장애인

Search Result 13, Processing Time 0.022 seconds

The Reliability of the K-PEQ(Korean Prosthesis Evaluation Questionnaire) in Lower Extremity Amputees (절단장애인을 위한 한국어 의지평가 설문지의 신뢰도)

  • Seong, Woo-Sung;Kim, Jang-Hwan;Jeong, Dong-Hun
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1405-1412
    • /
    • 2018
  • Korean-PEQ (prosthesis evaluation questionnaire) was developed and verified its validity research but, evaluating its reliability applied to the lower extremity amputees have not been conducted. The aim of this study was to apply the Korean-PEQ for lower extremity amputees to evaluate the reliability. As a result, all of the items responding of Korean-PEQ shown to less than 15% ceiling effect and floor effect. therefore, the results were shown to be appropriate. Korean-PEQ reliability of each region of intra-class coefficient was shown to .719(95% CI .600~.811)~920(95%CI .890~.945) and the inter-region reliability was higher as 0.958. Item internal consistency Cronbach's ${\alpha}$ values are shown as higher .910.

UV Treatment Technique for High Electrical Conductivity and Adhesion Strength of 3D Printed Circuit (3D 프린터로 제작된 회로의 전기전도성 및 접착강도 향상을 위한 UV 소결 기술)

  • Lee, Se-Hun;Gwon, O-Chang;Lee, Yu-Mi;Lee, Heon-Ju;Mun, Myeong-Un
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.340-340
    • /
    • 2015
  • 상지 절단 장애인들을 위한 미관형 의수는 95% 이상의 시장 보급률을 보인다. 하지만 외부 형상 향상에만 연구 초점이 맞추어져 있어 많은 장애인들이 의수를 착용할 때 차가운 표면으로 인해 이질감을 느낀다. 이로 인해 의수 제작 업체 및 절단 장애인들은 착용 시 이질감이 적은 의수의 보급을 희망하고 있다. 그러므로 본 연구에서는 인체와 유사한 온도를 발생시켜 이질감을 감소시키는 의수를 개발하기 위해 유연 기판인 TPU (Temperature Polyurethane)와 PET (Polyethylene terephthalate) 위에 상용 silver nano paste를 3D 프린터로 인쇄하였으며, UV 표면처리를 사용하여 단시간 내에 낮은 저항과, 높은 회로 접착강도를 갖는 회로를 개발 하였다.

  • PDF

Park Golf Participation of Physically Disabled Impact on Psychological Well-being and Subjective Happiness (파크골프 참여가 지체장애인의 심리적 웰빙과 주관적 행복감에 미치는 영향)

  • Kim, Dong Won
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.187-205
    • /
    • 2014
  • Is to identify how this affects the physically disabled to participate in the program 12 weeks Park Golf psychological well-being and happiness, the purpose of this research is subjective. How to study subjects, only 40-year-old disabled man more than 24 people total delay experimental group and 12 patients(failure cut seven, delayed dysfunction 5) and the control group and 12 patients(failure cut six, delayed dysfunction in 4, two people were involved in the joint disorder). 3 times a week(Mon, Wed, Fri), was carried out 50 minutes into 12 weeks of the experimental period, was located at River Park Golf Course A test place. We calculate the pre-and post-test data mean and standard deviation using SPSS Statistics 21.0 statistical data processing program, binary repeated measures ANOVA to analyze the effects on the psychological well-being of the disabled and subjective effects euphoria Park Golf Participation(was performed 2-way [2] RM ANOVA). First results in psychological well-being of the two groups according to Park Golf participate in group comparisons before and after the exercise involved only fun, immersive and shows were not significantly different, within each group enjoyment, competence, self-realization, all the children of the immersion showed a significant difference in the factors. Second, before and after participation in exercise, there was a significant difference between groups in subjective happiness of two groups according to Park Golf participation, the two groups were not significantly different within. Taken together the results to see more, showed that the positive effects on the psychological well-being and subjective happiness Park Golf participation is the Physically Disabled.

The Kinematics Analysis of Abscission Handicap Wheelchair Table Tennis (절단장애 휠체어 탁구 스트로크의 운동학적 분석)

  • Moon, Gun-Pill;Lim, Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2008
  • The objective of this study is to kinematically analyze forehand & backhand strokes of abscission handicap wheelchair table tennis athletes. The participant of this study were picked out of national athletes who have abscission handicap. Forehand stroke movement was expected to show a throw like motion. However, external rotation and internal rotation of the right arm created a backswing and an impact. Backhand stroke was expected to show a push like motion, and as expected, proximal part of the body didn't participate in the stroke motion, but the distal part, the right arm, rotated internally to backswing and external rotated to impact to form a push like motion. Forehand swing was expected to show throw like motion according to the Link Segmental System principle. However, abscission handicap athlete didn't show clear linking structure connecting proximal and distal parts. Successful strokes were dependant only on the angle of arm rotation.

Kinematic Analysis on Stroke in Wheelchair Table Tennis of Spinal Cord Injured Athletes and a Comparative Study with Abscission Athletes -Case Study of Medalists of Beijing 2008 Paralympics- (척수장애 휠체어 탁구 스트로크의 운동학적 분석 및 절단장애 선수와의 비교 -2008 베이징 장애인 올림픽 메달리스트 사례연구-)

  • Moon, Gun-Pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.151-159
    • /
    • 2008
  • In this research, kinematic comparative analysis was performed on strokes of abscission and spinal cord injured athletes who participated in 2008 Beijing Paralympics wheelchair table tennis games. Strokes of all situations were collected under real match-like conditions. Among those, three major forehand stroke motions and backhand stroke motions were drawn Data collected by 9 infrared cameras were expressed in angular motions using graphic program LabVIEW7.0. As a result, forehand stroke of spin handicap athlete from analyzed images, the rotations of the trunk happened with the rotations of shoulder and the flexion extensions of elbow nearly at the same time. According to these results, insufficient turning force or speed of rackets is recompensed using flexion. backhand stroke of spin handicap athlete from analyzed images, the rotations of the trunk, the flexion extensions of the elbow and the flexion extensions of the shoulder were lined up on the prolongations of ping-pong balls. Forehand stroke of abscission athletes was done by outward rotation of the arm using backswing and inner rotation. As for backhand stroke, backswing was made by inner rotation in the spin of shoulder and waist. And after the backswing, impact was formed in wide outer rotation towards the ball.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.

TREATMENT OF LINGUAL ULCERS CAUSED BY TONGUE THRUST WITH HYPOXIC-ISCHEMIC ENCEPHALOPATHY (저산소성 허혈성 뇌병변 환아에서 혀내밀기에 의해 발생된 혀 궤양의 치료: 증례 보고)

  • Oh, Mee-Hee;Kim, So-Jung;Choi, Sung-Chul;Kim, Kwang-Chul;Park, Jae-Hong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.8 no.1
    • /
    • pp.22-25
    • /
    • 2012
  • Hypoxic ischemic encephalopathy(HIE) is a condition that occurs when the entire brain is deprived of an adequate oxygen supply and associated in most cases with oxygen deprivation in the neonate due to birth asphyxia. Children with HIE develop problems such as cerebral palsy, mental retardation, learning difficulties, and other disabilities. We hereby report the case of treating a child patient with HIE whose chief complaint of severe lingual ulceration. A 12-month-old boy referred to our hospital to treat ulcers of ventral surface of tongue. He has been suffering from lingual ulceration due to persistent tongue thrusting. He has bitten his own tongue involuntary. The ulceration was apparently seemed to be not healed because of the constant irritation by lower incisors. So we designed tongue protector to prevent lingual ulcers. The appliance was proved to be effective to reduce tongue trauma by lower incisors and periodic follow-up is needed.

Design of Carbon Composite Prosthetic Feet using Finite Element Methods (유한요소 해석기법을 이용한 탄소복합소재 인공발의 설계)

  • Cho, Hyeon Seok;Cha, Gook Chan;Park, Jin Kook;Kim, Shin Ki;Lee, Suk Min;Mun, Mu Sung;Kim, Chang Bu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.769-776
    • /
    • 2013
  • The dynamic compliance characteristics of a prosthetic foot midgait are very important for natural performance in an amputee's gait and should be in a range that provides natural, stable walking. In this study, finite element analysis (FEA) and classical laminate theory were used to examine the mechanical characteristics of a carbon-epoxy composite laminate prosthetic foot as a function of variation in the lamination composition. From this analysis, an FEM model of a prosthetic keel, made from the composite material, was developed. The lamination composition of the keel was designed for improved stiffness. The prototype product was fabricated using an autoclave. Vertical loading response tests were performed to verify the simulation model. The results of the experiments were similar to those from simulations below the loading level of the gait, suggesting use of the proposed simulation model for prosthetic keel design.

Development of Customized Prosthetic Hand Using 3D Printing (3D프린팅을 이용한 사용자 맞춤형 의수 개발)

  • Moon, Mikyeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.110-117
    • /
    • 2018
  • The development of prosthetic hand or prosthetic leg equipment is steadily taking place globally. Though it would be difficult to create or feel the same way as a human hand, it would be a great for the amputated person if they can pick things up or do some movement as they want. It has become possible to develop low-cost prosthetic hand according to development of 3D printing technology. If people can develop personalized prosthetic equipment at similar prices to meet this trend, the utilization and penetration rate will be much higher. In this study, it describes how to develop a user-customizable prosthetic hand using 3D printing. To do this, the transformational parameters of prosthetic hand shape modeling are extracted as variability values, and the functions for controlling prosthetic hand motion are designed as software design patterns. This allows people who need a prosthetic hand to have their own prosthetic hand at a fast and affordable price.