• Title/Summary/Keyword: 전자 장비

Search Result 2,063, Processing Time 0.027 seconds

A Heat Shock Simulation System for Testing Performance of EWP (EWP 성능 검사를 위한 열 충격 모사시스템)

  • Yoo, Nam-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.553-558
    • /
    • 2019
  • Global auto parts companies are making efforts to develop EWP(: Electric Water Pump) which is one of the core parts of environment friendly car. In eco-friendly automobiles, an independent cooling system is used rather than a cooling system that is linked to an internal combustion engine. Therefore, the research and development of the water pump operating separately from the engine and the related production system are being actively carried out. In order to overcome the shortcoming of EWP of PPS material suitable for injection system, G company which is a global parts company that researches and develops EWP around SUS and is in the process of developing robot-based production equipment for mass production. In this paper, a heat shock simulation system is designed and implemented that works with the robot-based production system to test the performance of the produced EWP. By using this system, it is possible to test the EWP in an virtual environment similar to the actual environment, thereby reducing the defect rate of the product. At the same time, all the data produced during the entire process for testing can be stored, which can be utilized in the future development of CPS(: Cyber Physical System) of EWP system based on big data.

Development of Environmental Safety Real-Time Monitoring System by Living Area (생활권역별 환경안전 실시간 모니터링 시스템의 개발)

  • Lee, Joo-Hyun;Kim, Joo-Ho;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1088-1091
    • /
    • 2019
  • In this paper, a real-time monitoring system for environmental safety by living area is proposed. The proposed system is designed to measure radiation, fine dust and basic living information (temperature) using fixed and mobile measuring equipment, and constitutes a web database that stores data received from the equipment. It also develops web programs for displaying received data on PCs and mobile phones. The results of testing the performance of the system by an authorized testing agency showed that the radiation measurement range was measured in the range of $10{\mu}Sv/h$ to 10mSv/h, which is comparable to the world's highest level, and that the accuracy was measured between ${\pm}6.7$ and ${\pm}8.7$ percent of the measurement uncertainty was measured and normal operation at or below the international standard of ${\pm}15$ percent. In addition, the temperature test was conducted on a section of $-20^{\circ}C$ to $50^{\circ}C$ and normal operation was confirmed in response to the temperature change. Stability of radiated electromagnetic waves was ensured by a suitable judgment. The product's testing in general and high and low temperature environments for about four months after the prototype was made confirmed to be more than five years of durability. The measurement range and accuracy of fine dust sensors are compared with those of companies that measure the air environment, and the performance level is similar through the air quality measurement register.

Platelets as a Source of Peripheral Aβ Production and Its Potential as a Blood-based Biomarker for Alzheimer's Disease (말초 아밀로이드 베타 원천으로서의 혈소판과 알츠하이머병의 혈액 바이오마커로서의 가능성)

  • Kang, Jae Seon;Choi, Yun-Sik
    • Journal of Life Science
    • /
    • v.30 no.12
    • /
    • pp.1118-1127
    • /
    • 2020
  • Alzheimer's disease causes progressive neuronal loss that leads to cognitive disturbances. It is not currently curable, and there is no way to stop its progression. However, since medical treatment for Alzheimer's disease is most effective in the early stages, early detection can provide the best chance for symptom management. Biomarkers for the diagnosis of Alzheimer's disease include amyloid β (Aβ) deposition, pathologic tau, and neurodegeneration. Aβ deposition and phosphorylated tau can be detected by cerebrospinal fluid (CSF) analysis or positron emission tomography (PET). However, CSF sampling is quite invasive, and PET analysis needs specialized and expensive equipment. During the last decades, blood-based biomarker analysis has been studied to develop fast and minimally invasive biomarker analysis method. And one of the remarkable findings is the involvement of platelets as a primary source of Aβ in plasma. Aβ can be transported across the blood - brain barrier, creating an equilibrium of Aβ levels between the brain and blood under normal condition. Interestingly, a number of clinical studies have unequivocally demonstrated that plasma Aβ42/Aβ40 ratios are reduced in mild cognitive impairment and Alzheimer's disease. Together, these recent findings may lead to the development of a fast and minimally invasive early diagnostic approach to Alzheimer's disease. In this review, we summarize recent advances in the biomarkers of Alzheimer's disease, especially the involvement of platelets as a source of peripheral Aβ production and its potential as a blood-based biomarker.

A Study on the ILS Development & PLS Method for SI Weapon System based Commercial Items (상용품 기반 SI 무기체계의 효과적 ILS 개발 및 후속군수지원 방안)

  • Jeong, Inn-Sung;Lee, Yu-Se
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.417-425
    • /
    • 2020
  • Recently, the development of weapons systems in conjunction with the Fourth Industrial Revolution has increased the number of weapon systems that integrate individual commercial systems by actively incorporating the superior fields of private commercial technologies. In the case of such commercial product-based weapons systems, however, the development of ILS elements across all areas, such as technical manual, military field maintenance support equipment, interactive electronic technical manual (IETM), and Computer Based Training (CBT) development, and weapons system Reliability, Availability, Maintainability(RAM) target values, and logistics support analysis (LSA) was requested to expand the level of development by developers. The commercial product-based System Integration (SI) weapon system will be able to complete the comprehensive military balance for complementing and effective maintenance of the military and developers only when the ILS development, which is limited to the essential elements of the required group, Request For Proposal (RFP) and Post-Logistics Support (PLS) directions were applied in the framework of outsourcing maintenance implementation. As a result, by checking the operation status of current weapons systems, the logistics support of commercial product-based weapon systems selected outsourcing as the basic policy that is decided based on the development requirements, focusing on maintaining operation through a rational decision-making process, and presented a plan for applying the development plan to the RFP for the determined core elements and PLS.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

The Design of Smart Factory System using AI Edge Device (AI 엣지 디바이스를 이용한 스마트 팩토리 시스템 설계)

  • Han, Seong-Il;Lee, Dae-Sik;Han, Ji-Hwan;Shin, Han Jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.257-270
    • /
    • 2022
  • In this paper, we design a smart factory risk improvement system and risk improvement method using AI edge devices. The smart factory risk improvement system collects, analyzes, prevents, and promptly responds to the worker's work performance process in the smart factory using AI edge devices, and can reduce the risk that may occur during work with improving the defect rate when workers perfom jobs. In particular, based on worker image information, worker biometric information, equipment operation information, and quality information of manufactured products, it is possible to set an abnormal risk condition, and it is possible to improve the risk so that the work is efficient and for the accurate performance. In addition, all data collected from cameras and IoT sensors inside the smart factory are processed by the AI edge device instead of all data being sent to the cloud, and only necessary data can be transmitted to the cloud, so the processing speed is fast and it has the advantage that security problems are low. Additionally, the use of AI edge devices has the advantage of reducing of data communication costs and the costs of data transmission bandwidth acquisition due to decrease of the amount of data transmission to the cloud.

A Study on SUS MASK Etching Using Additives (첨가제를 이용한 SUS MASK 에칭에 관한 연구)

  • Lee, Woo-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.243-248
    • /
    • 2022
  • The purpose of this paper is to etching SUS MASK by adding an additive (F300) to FeCl3. The equipment used in the experiment is a self-made automatic liquid management system. The automatic liquid management system is a device capable of controlling the Oxidation Reduction Potential (ORP) and specific gravity in real time and supplying FeCl3 and additives in a quantitative manner. SUS MASK was etched in units from 10 sheets up to 200 sheets for 1 minute. It was confirmed that when the initial SUS MASK was 10 sheets, the ORP value started with 628 mV and measured at 611 mV from the time of 40 sheets being injected, and maintained close to 610 mV up to 200 sheets. The specific gravity was maintained near 1.640. And the SUS MASK was measured close to 0.4 mm from 50 sheets to 200 sheets. The experimental conditions of ORP had a specific gravity of 610 mV, 1.463, an etching pressure of 3.0 kg/cm2, an additive (F300) ratio of 1.2%, and the hole size was measured by up to 200 sheets of 10 sheets at once etching. As a result, the diameter approached 0.4 mm from 20 sheets. Even if the number of SUS MASK was increased, the ORP and specific gravity were well controlled, and it was confirmed that the experimental target value was close to 0.4 mm.

A Study on Eye Tracking Techniques using Wearable Devices (웨어러블향(向) 시선추적 기법에 관한 연구)

  • Jaehyuck Jang;Jiu Jung;Junghoon Park
    • Smart Media Journal
    • /
    • v.12 no.3
    • /
    • pp.19-29
    • /
    • 2023
  • The eye tracking technology is widespread all around the society, and is demonstrating great performances in both preciseness and convenience. Hereby we can glimpse new possibility of an interface's conduct without screen-touching. This technology can become a new way of conversation for those including but not limited to the patients suffering from Lou Gehrig's disease, who are paralyzed each part by part of the body and finally cannot help but only moving eyes. Formerly in that case, the patients were given nothing to do but waiting for the death, even being unable to communicate with there families. A new interface that harnesses eyes as a new means of communication, although it conveys great difficulty, can be helpful for them. There surely are some eye tracking systems and equipment for their exclusive uses on the market. Notwithstanding, several obstacles including the complexity of operation and their high prices of over 12 million won($9,300) are hindering universal supply to people and coverage for the patients. Therefore, this paper suggests wearable-type eye tracking device that can support minorities and vulnerable people and be occupied inexpensively and study eye tracking method in order to maximize the possibility of future development across the world, finally proposing the way of designing and developing a brought-down costed eye tracking system based on high-efficient wearable device.

A Study on CdTe Thin Film by RF Power Change (RF Power변화에 의한 CdTe 박막에 관한 연구)

  • Jung-Cheul Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.4
    • /
    • pp.187-192
    • /
    • 2023
  • This paper deposited CdTe thin films on ITO glass substrates using sputtering equipment while changing RF power. As a result of measuring the thickness of the thin film, 1481Å at 100W, 2985Å at 150W, and 4684Å at 200W. And the mobility was measured as 8.43 cm2/Vs for 100W, 7.91 cm2/Vs for 150W, and 6.57 cm2/Vs for 200W. It can be seen that the thickness and mobility of the thin film are inversely proportional. As a result of confirming the transmittance, the transmittance was 84% at 905nm for 100W, the transmittance was 71% at 825nm for 150W, and 77% at 874nm for 200W. At 100 W, the thickness of the thin film was thin, so the transmittance was measured to be high. In other words, the correlation between transmittance and thickness can be seen. As a result of measuring the FHWM and particle size by changing the RF Power, 100W was calculated as 0.18, 150W was calculated as 0.19, and 200W was calculated as 0.73. The size of the particles was formed at 8.47Å at 100W, 7.98Å at 150W, and 8.7Å, which is the largest at 200W. In conclusion, it was found that the FHWM and particle size were inversely proportional.

Real-time Monocular Camera Pose Estimation using a Particle Filiter Intergrated with UKF (UKF와 연동된 입자필터를 이용한 실시간 단안시 카메라 추적 기법)

  • Seok-Han Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.315-324
    • /
    • 2023
  • In this paper, we propose a real-time pose estimation method for a monocular camera using a particle filter integrated with UKF (unscented Kalman filter). While conventional camera tracking techniques combine camera images with data from additional devices such as gyroscopes and accelerometers, the proposed method aims to use only two-dimensional visual information from the camera without additional sensors. This leads to a significant simplification in the hardware configuration. The proposed approach is based on a particle filter integrated with UKF. The pose of the camera is estimated using UKF, which is defined individually for each particle. Statistics regarding the camera state are derived from all particles of the particle filter, from which the real-time camera pose information is computed. The proposed method demonstrates robust tracking, even in the case of rapid camera shakes and severe scene occlusions. The experiments show that our method remains robust even when most of the feature points in the image are obscured. In addition, we verify that when the number of particles is 35, the processing time per frame is approximately 25ms, which confirms that there are no issues with real-time processing.