• Title/Summary/Keyword: 전자파 무반사실

Search Result 27, Processing Time 0.019 seconds

Limits of Fully Anechoic Room for Radiated Disturbance Using Correlation Factor (야외시험장과 전자파 완전 무반사실과의 상관계수를 이용한 완전 무반사실의 허용 기준 제안)

  • Lee, Soon-Yong;Chung, Yeon-Choon;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1401-1411
    • /
    • 2010
  • In this paper, we suggested the tolerance limits of FAR(Fully Anechoic Room) using correlation factor between OATS(Open area Test Site) to measure EMI(Electromagnetic Interference) and FAR to measure EMS(Electromagnetic Susceptibility). FAR Project(SMT4-CT96-2133), CISPR/A/665/DTR, and CISPR A/665/DTR documents are analyzed and theoretical correlation factor based on the documents and theoretical equations is drawn. To obtain the experimental correlation factor, EUT(Equipment Under Test) is fabricated as well as measured at the 10 m distance OATS and in the 3 m distance FAR. Also, to suggest the tolerance limits of EUT with multi sources, radiation theory for electric and magnetic dipoles is programmed. We drew the correlation factor for EUT with multi sources through the programs. As the tolerance limits of FAR is newly defined, It can be used alternative test site for OATS to measure EMI, efficiently.

Comparison of Correlation Algorithms between GTEM Cell and Semi-Anechoic Chamber (GTEM 셀과 전자파 반-무반사실 사이의 상관관계 알고리즘 비교.분석)

  • 권종화;이애경;최형도
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.188-195
    • /
    • 2002
  • This paper statistically verifies two correlation algorithms by comparing the data of GTEM cell to those of semi-anechoic chamber (SAC). Correlation algorithms considered in this paper are 3 and 15 position methods, which simulate the EMI test for an equipment under test (EUT) over the ground plane by using the radiated power from EUT located within GTEM cell. Also, the results obtained by two algorithms are compared with the theoretical values calculated from an ideal dipole model. From the results, it was found that the data obtained by two correlation algorithms and SAC have a strong correlation. In addition, the EMI data by 3 position method showed higher than those by 15 position method and SAC measurements.

TEM 도파관을 이용한 전자파 장해 측정 연구 및 표준화 동향

  • 권종화
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.51-62
    • /
    • 2002
  • EMI/EMS 측정을 위해서는 주변 전자파 잡음(background noise)이 낮은 야외시험장(Open Area Test Site)이 가장 바람직하나, 근래 전자(전기 기기 사용의 증가와 방송.무선통신 시스템의 다양화로 인한 인공잡음(artificial noise)의 증대로 조건에 부합된 부지 선정이 어렵고, 설치 비용이 매우 크며 날씨 변화에 따라 시험 계획이 변경 될 수도 있는 단점이 있다. 전자파 분-무반사실(Semi Anechoic Chamber)은 대부분의 환경 잡음을 감쇠시키므로 야외시험장처럼 장소의 구애를 받지 않아 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하다. 그러나 큰 설치 공간과 많은 시설 유지 비용을 필요로 하며, 저주파 대역에서는 반사에 의한 공진을 완전히 제거할 수 없어 성능이 떨어진다. 또한, 최근 컴퓨터 CPU의 동작주파수가 급속하게 높아지고 PCS, IMT-2000 등과 같은 이동전화의 사용주파수도 계속해서 높아짐에 다라 미연방통신위원회(Federal Communication Commission)에서는 5㎓까지의 복사 방출 시험을 요구하고 있다. IEC 61000-4-3 복사 내성 시험규격도 휴대폰 주파수인 2㎓까지 확장되었으며 IMT-2000, Bluetooth 등 새로운 이동통신서비스가 속속 개발됨에 따라 18㎓ 까지 시험 주파수가 확장되는 추세이다. 그러나, 현재 국내 각 연구실에서 보유하고 있는 야외시험장이나 전자파 반-무반사실의 경우 1㎓이상에서의 시험이 곤란하여 수 ㎓주파수대역에서 시험이 가능한 복사 및 내성시험 시설이 필요하게 되었다. 이러한 문제점들을 해결하기 위해 고안된 대용 측정 시설 중 대표적인 것이 TEM 셀이나 GTEM셀과 같은 TEM 도파관(waveguide) 형태의 장비들이다. 이들은 본래 EMS 측정을 위한 장비이지만 협소한 공간이나 외부와의 전자파 간섭의 우려가 없고, 설치가 비교적 자유로워 여러 연구기관에서 도파관 원리를 이용한 측정 방식을 연구(개발하여 범용적인 전자파 적합성 측정 장비로서 활용하고 있다. 야외시험장과 무반사실 등이 안테나에 의한 피시험기기 주변 공간에서의 1점 측정으로 인해 시험 시간이 많아 소요되는 공통적인 단점이 있는 반면, TEM 도파관에 의한 측정은 일단 피시험기기의 모델링 정보만 얻어지면 계산에 의해 EMI 측정을 바로 할 수 있다. <표 1>에서 현재 상용화되어 사용되고 있는 TEM/GTEM 셀, 야외 시험장 및 전자파 무반사실에 대해 EMI 측정과 관련된 몇 가지 사안에 대해 비교하였다. 본 문서에서는 야외시험장이나 전자파 반-무반사실 등과 같은 기존 EMI/EMS 측정 시설의 단점을 보완하고, 광대역 특성을 갖는 대용 측정 시설로서의 TEM 도파관에 대해 소개하고 야외시험장 결과와의 상관관계 알고리즘 및 표준화 동향에 대해 기술하였다. 2절에서는 대표적인 TEM 도파관 구조의 측정 시설인 TEM 셀과 GTEM 셀의 전기적.구조적 특징에 대해 간단히 기술하고, 3절에서는 TEM 셀과 GTEM 셀에서이 측정결과를 이용하여 야외 시험장 결과를 얻어내는 상관관계 알고리즘에 대해 기술하였다. 4절에서는 IEC/CISPR와 TC77에서의 표준화 활동을 중심으로 현재 진행중인 TEM 도파관 관련 표준화 동향과 내용에 대해 기술하고자 한다.

The Characteristics of Field & Mode Distributions in a Cylindrical Reverberation Chamber (원통형 구조 전자파 잔향실 내 모드 및 필드 분포 특성)

  • 김정훈;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.431-436
    • /
    • 2003
  • In this paper, simulation results of an electromagnetic field and mode distributions in a cylindrical reverberation chamber were presented. Reverberation chamber is an alternative test facility for a semi anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity tests. The method of computing the number of modes in a cylindrical reverberation chamber was presented and the number of modes in a cylindrical reverberation chamber with the same volume was compared with the different ratio of radius to height. The FDTD method was used to produce field characteristics inside of rectangular, right-angled isosceles triangular, and cylinder type reverberation chambers with the same test volume.

Electromagnetic Field Distribution Analysis on Reverberation Chamber using Electromagnetic Diffusion Method (전자파 확산방식을 이용한 잔향실 내부의 필드 분포 해석)

  • 이광순;이중근;정삼영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.839-848
    • /
    • 2000
  • This paper presents the results of an electromagnetic field analysis for a reverberation chamber that is an alternative method of a shielded anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity test. Inside the defined test volume of the rectangular and triangular type, the Schroeder Quadratic Residue Diffuser was employed. FDTD(Finite-Difference Time-Domain) simulation method was applied to produce the field characteristics inside those reverberation chambers. According to the results, field uniformities on the aforementioned two types of reverberation chambers were correlated within $\pm$3dB, and $\pm$4.4dB tolerances, and rectangular type reverberation chamber shows an independent polarization result.

  • PDF

저가의 EMI/EMS 측정 시스템 - 표준, 개량형 TEM Cell

  • 윤재훈;이애경
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • 일반적으로 EMI 측정시험장으로 활용되고 있는 시설로서는 야외 시험장(open site)과 전자파 무반사실 (anechoic chamber)이 있다. 전자의 경우는 전자파 간섭 영향이 없어야 하고 반사 또는 커플링의 영향을 줄 수 있 는 장애물이 없어야 하는 시험환경 조건이 요구되지만, 근래의 전자기기 사용증가, 방송, 무선 통신시스템의 다양화 및 산업의 복잡화에 따른 인공잡음의 증대로 그 선정이 극히 어려워 도시에서 멀리 떨어진 곳, 즉 연구 개발 및 제품 생산 소재지로 부터 멀리 떨어진 곳에서나 가능하게 되었으며, 그외에도 기상조건에 의한 영향 및 주변 개발에 의한 잡음 환경의 변화로 성능 보존이 어렵다. 후자의 경우는 야외 시험장의 전자파 환경 문제점을 피할 수 있어, 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하나 이들 모두 수억에서 십수억원에 이르는 설치 비용이 들어 중소 업체에서 보유하기가 어렵다. 또한 안테나 를 송수신원으로 사용하므로서 저주파수대 측정이 어려울 뿐만 아니라 피시험체주변 공간(반경 3, 10M)에서의 1점 측정 방식으로 인해 측정시간이 많이 소요되는 기술적인 문제점을 지니고 있다.

  • PDF

Improvement of Field Uniformity in a Reverberation Chamber with Various Numbers of a 2D CRD (2D CRD 수에 따른 전자파 잔향실 내의 필드 균일성 개선)

  • Kim, Jin-Bok;Rhee, Joong-Geun;Kim, Jung-Hoon;Rhee, Eu-Gene
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • This paper presents the improvement of the field uniformity in a reverberation chamber which can be substitute an anechoic chamber for the electromagnetic interference (EMI) and immunity test. Nowadays, there are many EMI issues due to the increasing use of wireless local area network (LAN), digital multimedia broadcasting (DMB), and mobile internet. With this reason, this paper studied the field characteristics in a reverberation chamber for 2.3 GHz band. In this paper, the finite difference time domain (FDTD) method is used to analyze the field characteristics in a reverberation chamber. To improve the field uniformity in the reverberation chamber, this paper adopted a 2D cubical residue diffuser (CRD) with varying the disposition and number of CRD. For each case, the tolerance and standard deviation of the electric field strength are evaluated. In comparison with the reverberation chamber without any CRD, the reverberation chamber with two CRDs showed improved results; 1.98 dB improvement in standard deviation and 3.6 dB improvement in tolerance.

Radiation Pattern and Radio Sensitivity of PCS Band Mobile Phones with Internal Antenna and External Antenna (PCS 대역 안테나 내장형 단말기와 외장형 단말기의 방사패턴과 무선감도)

  • 공성신;오종대;양운근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.397-405
    • /
    • 2004
  • In this paper, performance analysis of mobile phone with internal antenna for PCS band was carried out. The radiation patterns for antenna and mobile phone with internal antenna were simulated by using 3D simulation program, HFSS and SEMCAD. Radiation pattern variation was observed according to installation of LED circuit and ground pattern and by using simulation radiation pattern was improved. And radiation patterns of mobile phones with internal and external antennas were measured by using for field measurement system and chamber. Measured radiation pattern for mobile phone with internal antenna shows good agreement with simulation result. And the radio sensitivities of mobile phones with internal and external antennas were measured by using Agilent E5515C and chamber and compared. The measured radio sensitivity of mobile phone with internal antenna shows proper performances comparable to other model with external antenna. Measured result shows that the difference on averaged co-polar radio sensitivity is 0.12 ㏈.