• Title/Summary/Keyword: 전자선형가속기

Search Result 8, Processing Time 0.029 seconds

A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method (46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.245-249
    • /
    • 2013
  • Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for resonance energy measurement of natural tantalum. BGO($Bi_4Ge_3O_{12}$) scintillation detectors used for measurement of the prompt gamma ray from the natural tantalum sample. The BGO spectrometer was composed geometrically as total energy absorption detector. The electric signal from the spectrometer was analyzed for TOF(Time-of-Flight) spectrum which is used identification of neutron capture resonance energy. In this study, the neutron energy region is from 1 to 200 eV, because of strong X-ray effect produced photonuclear reaction in Ta target, the measurement was performed to below 1 keV energy region. The resonance energy was compared with the evaluated values(ENDF/B-VI, Mughabghab). All of the resonances from 4.28 ~ 200 eV were seen in the present measurement except 144.3 eV resonance.

Contamination of the 6MV Linear Accelerator Photon Beam by Electrons (6MV 전자 선형 가속기 광자선의 전자오염)

  • Yoo, Meong-Jin;Kim, Dong-Won;Chung, Woon-Hyuk
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 1988
  • The 6 MV photon beam of a linear accelerator (Mevatron 67) was studied for electron contamination. The surface dose, attributable almost entirely to contamination electrons, has a linear dependence on field width for square fields and an inverse square dependence on distance from the bottom of the fixed head assembly. Build-up and surface dose measurements were taken with and without an acrylic blocking tray in place. Further measurements were made with a copper filter designed to reduce secondary electrons emitted by photon interactions with the acrylic tray. The results are discussed in relation to skin sparing effect for radiation therapy patients. To achieve the maximum skin sparing effect, the selection of the optimum SSD and TSD is needed.

  • PDF

A Study on Neutron Resonance Energy of 180Ta below 1eV Energy (1 eV 이하 에너지 영역에서의 180Ta 동위원소의 중성자공명에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.287-292
    • /
    • 2014
  • In this study, the neutron capture cross section of $^{180}Ta$(natural existence ratio: 0.012 %) obtain by measuring has been compared with the evaluated data for the capture data. In generally, the neutron capture resonance is defined as Breit-Wigner formula. The formula consists of the resonance parameters such as neutron width, total width and neutron width. However in the case of $^{180}Ta$, these are very poor experimental neutron capture cross section data and resonance information in below 10 eV. Therefore, in the study, we analyzed the neutron resonance of $^{180}Ta$ with the measuring the prompt gamma-ray from the sample. And the resonance was compared with the evaluated data by Mughabghab, ENDF/B-VII, JEFF-3.1 and TENDL 2012. Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for cross section measurement of $^{180}Ta(n,{\gamma})^{181}Ta$ reaction. $BGO(Bi_4Ge_3O_{12})$ scintillation detectors used for measurement of the prompt gamma ray from the $^{180}Ta(n,{\gamma})^{181}Ta$ reaction. The BGO spectrometer was composed geometrically as total energy absorption detector.

Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system (X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가)

  • Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1035-1039
    • /
    • 2010
  • Activation products generated by photoneutrons in concrete shielding wall around electron linac were estimated for a high energy X-ray container cargo inspection system. Monte carlo code, MCNPX2.5.0 was used for reference system of 9MeV fixed type dual-direction container cargo inspection system installed at major harbors in Korea. Activation products inventory generated by photoneutron (n,$\gamma$) reaction are estimated, and then radiation dose rate is calculated from the results.

Measurement of Energy Dependent Differential Neutron Capture Cross-section of Natural Sm by Using a Continuous Neutron Flux below (연속에너지 중성자에 대한 천연 Sm의 중성자 포획단면적 측정)

  • Yoon, Jungran
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.337-341
    • /
    • 2016
  • We measured the neutron capture cross-section of natural Sm(n,${\gamma}$) reaction in the energy regions from 0.003 to 10 eV. The 46-MeV electron linear accelerator of Research Reactor Institute, Kyoto University was used for generating a continuous neutron source. The neutron time-of-flight method was adopted for energy measurement. An assembly of BGO($Bi_4Ge_3O_{12}$) scintillators composed of 12 pieces of BGO crystals measured prompt gamma rays from Sm(n,${\gamma}$) reaction. The BGO assembly was located at a distance of $12.7{\pm}0.02m$ from the neutron source. In order to determine the neutron flux impinging on the Sm, the $^{10}B(n,{\alpha}{\gamma})^7Li$ standard cross-section were used. Natural Sm(n,${\gamma}$) reaction measurement result of the neutron capture cross-section was compared with the results of evaluation of the BROND-2.2 and the previous experimental data of J. C. Chou and V. N. Kononov.

A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging (전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구)

  • 윤성익;권수일;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.105-113
    • /
    • 1998
  • Accurate radiation dosimetric characters is very important to determine of dose to a radiotherapeutic patient. Medical linear accelerators have been developed not only its new quality of convenient operation but also electric moderation. It is reliable to measure more detail physical parameter that linac's internal ability. Typically, radiation dosimetric tool is classified ionization chamber, film, thermoluminescence dosimeter, etc. Nowaday, Electronic Portal Imaging Device is smeared in radiation field to verification of treatment region. EPID's image was focused that using both on-line image verification and absolutely minimum absorbed dose during radiotherapy. So, Electronic Portal Imaging was tested for quality evaluation of medical linear accelerator had its pure conditional flash. This study has performed symmetry, Light/Radiation field congruence, and energy check, geometry difference on wedge filter using a liquid filled ion chamber (EPID). Prior to irradiated on EPID, high energy photon beam is checked with ion chamber. Using these results more convenient dosimetric method is accomplished by EPID that taken digital image. Medical image is acquired with EPID too. Therefore, EPID can be analyzed by numerical information for what want to see or get more knowledge for natural human condition.

  • PDF

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.