• Title/Summary/Keyword: 전자냉각시스템

Search Result 122, Processing Time 0.025 seconds

Real-Time Fixed Pattern Noise Suppression using Hardware Neural Networks in Infrared Images Based on DSP & FPGA (DSP & FPGA 기반의 적외선 영상에서 하드웨어 뉴럴 네트워크를 이용한 실시간 고정패턴잡음 제어)

  • Park, Chang-Han;Han, Jung-Soo;Chun, Seung-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.94-101
    • /
    • 2009
  • In this paper, we propose design of hardware based on a high speed digital signal processor (DSP) and a field programmable gate array (FPGA) for real-time suppression of fixed pattern noise (FPN) using hardware neural networks (HNN) in cooled infrared focal plane array (IRFPA) imaging system FPN appears a limited operation by temperature in observable images which applies to non-uniformity correction for infrared detector. These have very important problems because it happen serious problem for other applications as well as degradation for image quality in our system Signal processing architecture for our system operates reference gain and offset values using three tables for low, normal, and high temperatures. Proposed method creates virtual tables to separate for overlapping region in three offset tables. We also choose an optimum tenn of temperature which controls weighted values of HNN using mean values of pixels in three regions. This operates gain and offset tables for low, normal, and high temperatures from mean values of pixels and it recursively don't have to do an offset compensation in operation of our system Based on experimental results, proposed method showed improved quality of image which suppressed FPN by change of temperature distribution from an observational image in real-time system.

An Experimental Study on Pressure Drop and Heat Transfer Coefficient of Laminar Ag Nanofluid Flow in Mini-Tubes (은 나노유체의 미세관내 층류 유동의 압력강하 및 열전달계수에 관한 실험적 연구)

  • Kwon, Jeong-Tae;Nahm, Taek-Hun;Kim, Tae-Wan;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3525-3532
    • /
    • 2009
  • This study presents the heat transfer and pressure drop characteristics of Ag nanofluid in mini-tubes(outer diameters of 1/8inch, 3/16inch). Experiments were performed for Reynolds numbers ranged from 500 to 2,500 and nanofluid concentrations of 0.1 and 0.3vol.%. The pressure drop of nanofluid flow increased by max. 21% compared with that of distilled water. The heat transfer coefficients of the nanofluid of 0.1 vol.% enhanced 3~42% for 1/8inch tube, and 3~69% for 3/16inch tube. Also, the heat transfer coefficients of the nanofluid of 0.3 vol.% enhanced 35~65% for 1/8inch tube, and 62~125% for 3/16inch tube. From the results Ag nanofluid can be a better candidate as a coolant than distilled water when using in mechanical and/or electronic systems.

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

A Study on the Method for the Removal of Radioactive Corrosion Produce Using Permanent and Electric Magnets

  • Kong Tae-Young;Song Min-Chul;Lee Kun-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • The removal of radioactive corrosion products from the reactor coolant through a magnetic filter system is one of the many approaches being investigated as a means to reduce radiation sources and exposures to the operational and maintenance personnel in a nuclear power plant. Many research activities in water chemistry, therefore, have been performed to provide a filtration system with high reliability and feasibility and are still in process. In this study, it was devised the magnetic filter system with permanent and electric magnets to remove the corrosion products in the coolant stream taking an advantage of the magnetic properties of corrosion particles. Permanent magnets were used for separation of corrosion products and electric magnets were utilized for flocculation of colloidal particles to increase in their size. Experiments using only permanent magnets, in the previous study, displayed the satisfactory outcome of filtering corrosion products and indicated that the removal efficiency was more than 90 $\%$ for above 5 $\mu$m particles. Experiments using electric magnets also showed the good performance of flocculation without chemical agents and exhibited that most corrosion particles were flocculated into larger aggregates about 5 $\mu$m and over in diameter. It is, thus, expected that the magnetic filter system with the arrangement of permanent and electric magnets will be an effective way for the removal of radioactive corrosion products with considerably high removal efficiency.

  • PDF

A Study of Dynamic Performance Improvement of Linear Compressors Using Phase Control Loop (리니어 컴프레서의 위상제어를 통한 동특성 향상에 관한 연구)

  • Nam, Jae-Woo;Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a phase control system has been implemented to improve the dynamic performance of the stroke response for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which liner compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. A phase control system is added to the stroke control loop and the superior performance of the phase control system is verified via some simulation studies.

Control of Small PEM Fuel Cell Stack by a Microprocessor (마이크로프로세서를 이용한 소형 PEM 연료전지 스택의 제어)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.469-475
    • /
    • 2008
  • In this paper, control of small PEM(Proton Exchange Membrane) fuel cell stack by a microprocessor is introduced. The water management of fuel cell stack inside, a key technique in fuel cell control, can be achieved by adjusting the required air flow for fuel and cooling, and by purging the excessive water from the stack. It is very important to precisely control the BOS(Balance of Stack) since the stable operation of the fuel cell system mainly depends on it. In this study the fuel efficiency of the system is improved by the control of the system based on the measured air flow and purge cycle during the optimal operation and its effectiveness is proved by the experiments. The operating stability of the system is improved by the developed controller using a microprocessor and it is expected to be widely used for the control of small PEM fuel cell stack.

A Study on High Frequency Induction Hardening of S45C Specimen by FEA and Experiment (유한요소해석 및 실험에 의한 S45C 시편의 고주파 유도경화에 관한 연구)

  • Park, Kwan-Seok;Choi, Jin-kyu;Lee, Seok-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.1-7
    • /
    • 2018
  • In this study, we proposed a high frequency induction hardening analysis method based on electromagnetic-thermal co-simulation. In the high frequency induction heating analysis, the results of the finite element analysis (FEA) (considering the change of the material property and the cooling factor according to the temperature) and those of the high frequency induction hardening experiment (using the S45C specimen) were compared. The hardness of the S45C specimens was measured using the micro Vickers hardness test to determine the depth of hardening. The measurement results were then compared with the results of FEA. The result of high frequency induction heating analysis showed that the temperature was more than $750^{\circ}C$, which is the A2 transformation point of S45C, while the temperature during quenching was below $200^{\circ}C$. The results showed that the difference of the depth of hardening between the FEA and the experiment is 0.2mm.

Implementation of Electrical Performance Test Evaluation System for Car Fuel Heater (차량 연료히터의 전기적 성능시험 평가 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.63-70
    • /
    • 2013
  • In this paper, we have implemented the performance evaluation system of the unified fuel heater for CRDI diesel engine. If the diesel engine be cold by low temperature in winter, then that makes the waxing materials like a paraffin and is the source of poor engine starting. The unified fuel heater is the barrow meter that estimate the start performance of diesel engine, and be tested by test chamber. The chamber perform the normal temperature, an extremely low temperature, an operating performance in an extremely high temperature, the resistance operation delay time and current operation delay time in setting up test resistance, the bimetal delay time test in temperature variation, the current and resistor test of the composited heater, a heating operation test.

High Performance Control of SRM Drive System for Automobiles by C-dump Converter (C-dump Converter에 의한 차량용 SRM 구동 시스템의 고성능제어)

  • 김도군;윤용호;이태원;원충연;김영렬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.534-542
    • /
    • 2003
  • Small electric motors in an automobile perform various tasks such as engine cooling, pumping, HVAC etc. At present, most of them are DC motors supplied by 12V or 24V batteries. However, DC motors suffer from low efficiency, life cycles and reliability. Therefore, there is a growing interest in substituting DC motors for advanced at motors including switched reluctance motors(SRM). Although there are several other forms SRM convertors, they are either unsatisfactory to the control performance or unsuitable for the 12V battery source. Especially, a conventional asymmetric converter of SRM provides the best flexible and effective control to the current waveform of SRM, but it has the most switches and produces conducting voltage drops across two power switches during SRM operation. For automotive applications with a 12V battery source, this circuit is inadequate. For considering the requirement for effective operation and simple structure of converter in the limited internal circumstance of automobiles, the author inclines toward selecting Modified C-dump converter and Energy efficient c-dump converter.

Process Induced Warpage Simulation for Panel Level Package (기판 소재에 따른 패널 레벨 패키지 공정 단계별 warpage 해석)

  • Moon, Ayoung;Kim, Sungdong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.4
    • /
    • pp.41-45
    • /
    • 2018
  • We have simulated the process induced warpage for panel level package using finite element method. Silicon chips of $5{\times}5mm^2$ were redistributed on $122.4{\times}93.6mm^2$ size panel and the total number of redistributed chips was 221. The warpage at each process step, for example, (1) EMC molding, (2) attachment of detach core, (3) heating, (4) removal of a carrier, and (5) cooling was simulated using ANSYS and the effects of detach core and carrier materials on the warpage were investigated. The warpage behaved complexly depending on the materials for the detach core and carrier. However, glass carrier showed the lower warpage than FR4 carrier regardless of detach core material, and the minimum warpage was observed when the glass was used for the detach core and carrier at the same time.