• Title/Summary/Keyword: 전원공급시스템

Search Result 569, Processing Time 0.023 seconds

Efficient RFID Authentication protocol for Distribution Database Environment (분산시스템 환경에 적합한 효율적인 RFID 인증 시스템)

  • Choi, Eun-Young;Lee, Su-Mi;Lim, Jong-In;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.6
    • /
    • pp.25-35
    • /
    • 2006
  • Radio Frequency identification (RFID) will become an important technology in remotely object identification systems. However, the use of RFID tags may create new threats to the sniな and Privacy of individuals holding RFID tags. These threats bring several problems which are information leakage of a tag, location trace of individuals and impersonation of a tag. Low-cost RFID systems have much restrictions such as the limited computing power, passive power mechanism and low storage space. Therefore, the cost of tag's computation should be considered as an important factor in low-cost RFID systems. We propose an authentication protocol, OHLCAP which requires only one one-way hash function operation and hence is very efficient. Furthermore, our protocol is suitable to distribution database environment. Hence our scheme can be applied to ubiquitous computing environment.

Design of CRIO-based real-time controller for small-sized wind turbine generating system and comparative study on performance of various MPPT algorithms (소형 풍력발전 시스템을 위한 CRIO 기반의 실시간 제어 시스템 설계 및 다양한 형태의 MPPT 알고리즘 성능 비교 분석)

  • Kim, Su-Jin;Kim, Byung-Moon;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • The small-sized wind turbine generating system with the output power less than 10kW, which can be installed in some areas of hills, parks, and cities due to its flexibility, is one of the progressive research and development fields in renewable energy. It is important for the small wind turbine generators to have low cost, high reliability as well as high efficiency. To meet these requirements, development of various maximum-power-point-tracking (MPPT) control schemes should be required. Generally, the output of the controller can be connected to a 48V battery to supply power to a DC load. In this work, the design and implementation of an FPGA-based MPPT controller for small-sized wind turbine generating system is presented. For the verification of the practical performance of various MPPT algorithms, CRIO controller from NI has been used.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.

Wake-Up Receiver System Design Using the DGS Rectenna (DGS Rectenna를 이용한 Wake-Up 수신기 시스템 설계)

  • Choi, Tae-Min;Lee, Seok-Jae;Lee, Hee-Jong;Lim, Jong-Sik;Ahn, Dal;Han, Sang-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.377-383
    • /
    • 2012
  • In this paper, a new design of a planar rectenna system and its application to a wake-up receiver operating for incoming signal with a specified frequency are proposed for low-power sensor system applications. The planar and integrable rectenna system is designed with DGSs(Defected Ground Structures) at 2.4 GHz. The DGSs reject harmonic components of 4.8 and 7.2 GHz and eliminate 2.4 GHz fundamental frequency for DC-path filtering. The rectenna system has been evaluated for the conversion output voltages, and applied to the switching of a power supply at the low-power sensor receivers. The proposed system has been evaluated for the wake-up performance by testing a lownoise amplifier operation. From the experimental results, the proposed receiver system presents excellent operation performances.

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

Design of IoT-based Energy Monitoring System for Residential Building (IoT 기반 주택형 건물 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1223-1230
    • /
    • 2021
  • Recently, energy resource management is a major concern around the world. Energy management activities minimize environmental impacts of the energy production. This paper presents design and prototyping of a home electric energy monitoring system that provides residential consumers with real time information about their electricity use. The developed system is composed of an in-house sensing system and a server system. The in-home sensing system is a set of wireless smart plug which have an AC power socket, a relay to switch the socket ON/OFF, a CT sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to residential consumers. We analyzed and presented energy consumption data from electrical appliances for 3 months in home. The experimental results show the promising possibilities to estimate the energy consumption patterns and the current status.

Improvement on the System of Information to the Public for Chemical Accident Emergency Response (화학사고 응급정보에 대한 주민제공 체계 개선 방안)

  • Park, Hyesong;Song, Chi-sun;Shin, Chang-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.571-579
    • /
    • 2019
  • To minimize the damage from chemical accidents, a risk management plan (RMP) has been implemented since 2015. According to this regulation, operators who handle more than the designated quantity of the accident preparedness chemicals should provide emergency response information to the public within the affected areas of accidents. The information, including chemicals, affected areas and evacuation instructions should be provided to the public in advance so that they can evacuate immediately in the event of a chemical accident. Currently, the information notification can be provided in various methods by being registered in the notification system, sent with written documents or delivered directly to the public. To examine the status of the operation method, this study analyzed similar cases overseas, investigated the degree of awareness of providing information through the number of the annual visitor of the Information Provision System, and obtained survey results from some residents. This current operation method are problems because the public, who do not have sufficient information about chemicals, do not understand the emergency information properly or it is difficult to recognize where the residents should find this information because of the convenient operation based on the information provider. In this study, measures were proposed to minimize the damage by making it easier for the public to understand the emergency information and the information communicated appropriately in advance by dividing them into an information providing method and post management.

Implementation a of data repeating system using solar charging and develop algorithm for data repeating in the pasture (산지초지에서 한우 활동량 정보 수집을 위한 데이터 중계 알고리즘 및 시스템 구현)

  • Kim, Suc-Jun;Kim, Jong-Won;Kim, Chun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.285-293
    • /
    • 2016
  • In the paper, we propose a data transmission repeating system that allows data transmission for the effective supervision of cows grazing in the pasture. It is normal practice to divide the pasture into different areas for the purpose of distributing the grazing. However, this makes it difficult to supply electrical power and transmit data, because some of the pastures are far away from the office used for collecting data. To solve this problem, we developed a repeating system that can allow data transmission in the pasture using a solar charging system that consists of a 60W solar panel, 12V/100A battery and 6A solar controller for the power supply and a data transmission algorithm which extends the range of data transmission when using the proposed repeating system. We verified the performance of the repeating system by checking whether the data transmission is successful or not when transmitting from various test points when there is an obstacle between the receiver and repeating system. We also verified the solar charging system by measuring the battery voltage when the system is operated continuously for 31 days and whether the system can supply sufficient power when the weather is cloudy or rainy for a few days. Finally, we verified the performance of the repeating system and data transmission algorithm by conducting experiments in a pasture.

Efficiency and Power Factor Improvement of Induction Motor Using Single-Phase Back Rectifier (단상 강압 정류기를 이용한 유도전동기의 효율 및 역률 개선)

  • 문상필;이현우;서기영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.22-29
    • /
    • 2002
  • Usually, much harmonics are included and cause harmonic loss of motor, torque pulsation, electro-magnetic noise and shock etc. by switching function of inverter when drive induction motor variableness inside. It applied partial resonant Buck converter and three phase voltage type SPWM inverter circuit to induction motor driving system in this paper that see to solve such problem. Changed operation condition variously to do input current of circuit that propose sine-wave by unit power factor almost and capacitor supplied bringing back to life voltage by power supply arranging properly assistance diode and electric power switching. Power factor and efficiency improved as that minimize variation of input at power supply voltage polarity reverse by that add voltage reversal function. Also, by using output filter, reduced harmonic of output line to line voltage components, and introduce state space analysis and forecast operation of rectifier. Such all items confirmed validity through simulation and an experiment.

Circuit DQ Modeling and Analysis of Operating Characteristics for Hybrid Cascade Five-level PWM Rectifier (하이브리드 Cascade 5-레벨 PWM 정류기의 회로 DQ모델링 및 동작특성 해석)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.817-824
    • /
    • 2000
  • This paper presents circuit DQ modeling and analysis of operating characteristics of hybrid cascade multilevel PWM rectifier, especially five-level, without isolation transformers. The circuit DQ transformation changes the original three-phase time varying circuit to stationary equivalent one by employing the synchronously rotating transformation matrix. As a result of circuit DQ modeling, the operating characteristics and some useful design relationships for the system are obtained with ease. That is, the analytic equations for DC voltages and active/reactive power supplied by source with respect to control variables are Presented. Moreover, the DC voltages for the multilevel output generation may be directly built up from AC utility source and the important control equation ensuring 5-level output voltage is obtained. Finally, to confirm the validity of the analysis, MATLAB simulations are carried out and the simulation results show good agreements between analytic predictions and the simulated waveforms.

  • PDF