• Title/Summary/Keyword: 전압 프로브

Search Result 43, Processing Time 0.024 seconds

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.

Poly-tetrafluoro-ethylene와 polyethylene 튜브 내부에 형성된 유전체 장벽 방전의 전류-전압 특성에 대한 연구

  • Jo, Yong-Gi;Choe, Yu-Ri
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.331.1-331.1
    • /
    • 2016
  • 내부지름이 2.0 mm 이하인 PTFE와 PE 튜브에 진공장치를 이용하여 튜브 내부의 압력을 감압하여 진공상태를 형성하였다. 진공기밀 후에 반응성 가스를 인입하여 튜브 외부에 장착된 전극을 통하여 고전압의 AC 전압을 인가하여 튜브 내부에 선택적으로 유전체 장벽 방전을 유도하였다. 본 연구에서는 유전율이 3.0 이하로 낮은 PTFE와 PE 튜브에 유전체 장벽방전이 유도될 때 나타나는 전압과 전류의 파형을 분석하여 방전의 개시와 방전의 형태를 조사하였다. 주파수 40 kHz인 AC 전원(PEII, Advanced Energy)과 Loadmatch 모듈을 이용하여 4 kV 이하의 전압을 인가하여 플라즈마 방전 유도하였다. 튜브에 인가고전압 프로브와 전류 프로브를 이용하여 오실로스코프를 I-V 분석을 실시하였고, 실험 결과 대기압 방전에서 유도되는 유전체 장벽방전의 I-V 특성과 달리 방전의 형태가 유전체장벽방전과 글로우방전이 혼합된 형태로 나타났다. 또한 유전체 장벽방전을 통해 튜브 내부에 형성되는 플라즈마에 대한 분석으로 OES 광분석을 실시하여, 방전 시간과 전압 변화에 따른 고분자 표면으로부터 방출되는 활성종에 대한 분석을 실시하였다.

  • PDF

Characteristics of the Detection Voltages of an E-field Sensing Probe in SAR Measurement System (전자파 비흡수율(SAR) 측정용 전기장 프로브의 검파 전압 특성)

  • Gimm Youn-Myoung;Lee Seung-Bae;Kim Ki-Hwea
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.217-221
    • /
    • 2005
  • The E-field intensity by mobile handsets in a phantom is measured by a 3 axes miniature probe. The detected DC voltage by a Schottky diode in a probe has nonlinear characteristics by itself. If a pertinent diode compression point (DCP) is applied for the compensation specific absorption rate(SAR) as much as 200 W/kg can be measured with a good measurement accuracy.

액체 내에 적용 가능한 바이오 플라즈마 소스 개발과 특성 연구

  • Im, Seung-Ju;Min, Bu-Gi;O, Hyeon-Ju;Lee, Jong-Yong;Gang, Seung-Eon;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.495-495
    • /
    • 2013
  • 액체 내에 적용 가능한 바이오 플라즈마 소스를 제작하기 위해 텅스텐과 주사 바늘, 카테터 등의 여러 재료를 사용하여 시도를 해보았고 액체에서 방전이 일어날 수 있는 구조를 연구하였다. 전극 위에 절연체를 씌우고 그 위에 전극을 고정시켜 전압을 인가하여 전극 간에 표면방전을 통해서 플라즈마를 생성하는 방식을 사용하였다. 실험 장비는 AC 전압을 사용하였으며(12 kV, 22 kHz) 방전 전압과 방전 전류를 고전압 프로브(Tektronix P6015A)와 전류 프로브(P6021)를 사용하여 측정하였다. 모노크로미터를 이용하여 바이오 플라즈마 소스가 액체 속(수돗물, 증류수, 생리식염수)에서 방전 될 때 에미션 스펙트럼을 분석하여 산화질소(nitric oxide; NO), 과산화수소(hydrogen peroxide; H2O2), hydroxyl radical이 발생함을 확인하였다. 인체 내에서는 온도가 중요한 요소이기 때문에 액체에서 방전할 때 $40^{\circ}C$ 이하의 낮은 온도에서 이용이 가능하도록 연구하였다. 특히, 우리는 여러 종류의 액체(수돗물, 증류수, 생리식염수)에서의 방전 특성의 광학적 전기적 연구를 하였다.

  • PDF

Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor (지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구)

  • Son, Eun-Won;Youn, Ji Won;Kim, Dae Up;Lim, Jae-Won;Kim, Kwang-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.73-77
    • /
    • 2017
  • Recently, fingerprint sensors have widely used for personal information security, and require quality evaluation to reduce an error of their recognition rate. Quality of fingerprint sensors is evaluated by variation of their electrical resistance introducing by contacts between a probe tip and a sensor electrode, Investigation on the materials compatability and structure optimization of probe is required to reduce deformation of sensor electrode for repeatability of quality testing. Nickel, steel(SK4), beryllium copper, and phosphor bronze were considered as probe materials, and beryllium copper was the most appropriate for materials of probe tips, considering indentation and contact resistance while being contacted probe tips on electrodes. Probes of an inspection part were manufactured with the single-unit structure for physical damage prevention and parallel processing capability. Inspection repeatability was evaluated by voltage variation of fingerprint sensors when the specific current was applied. A single-unit inspection part with beryllium copper probe tips showed excellent repeatability within ${\pm}0.003V$ of its voltage variation.

BCI Probe Emulator Using a Microstrip Coupler (마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator)

  • Jung, Wonjoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) test is a method of injecting current into Integrated Circuit(IC) using a current injection probe to qualify the standards of Electromagnetic Compatibility(EMC). This paper, we propose a microstrip coupler structure that can replace the BCI current injection probe that is used to inject a RF noise in standard IEC 62132-part 3 documented by International Electrotechnical Commission. Conventional high cost BCI probe has mostly been used in testing automotive ICs that use high supply voltage. We propose a compact microstrip coupler which is suitable for immunity testing of low power ICs. We tested its validity to replace the BCI injection probe from 100 MHz to 1,000 MHz. We compared the power[dBm] that is needed to generate the same level of noise between current injection probe and microstrip coupler by sweeping the frequency. Results show that microstrip coupler can inject the same level of noise into ICs for immunity test with less power.

Loop Probe Design and Measurement of Electromagnetic Wave Signal for Contactless Cryptographic Analysis (비접촉 암호 분석용 루프 프로브 설계 및 전자파 신호 측정)

  • Choi, Jong-Kyun;Kim, Che-Young;Park, Jea-Hoon;Moon, Snag-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1117-1125
    • /
    • 2007
  • In this paper, a study has been performed on the design of small loop probe and analysis of induced electromagnetic wave signal from a smartcard for contactless cryptographic analysis. Probes for cryptographic analysis are different from conventional EM probes, because the purpose of proposed probe is to obtain the information for secret key analysis of cryptographic system. The waveform of induced voltage on probe must be very close to radiated waveform from IC chip on smartcard because electromagnetic attack makes an attempt to analyze the radiated waveform from smartcard. In order to obtain secret key information, we need to study about cryptographic analysis using electromagnetic waves, an approximate model of source, characteristic of probe for cryptographic analysis, measurement of electromagnetic waves and calibration of probes. We measured power consumption signal on a smartcard chip and electromagnetic wave signal using proposed probe and compared with two signals of EMA point of view. We verified experimently the suitability of the proposed small loop probe for contactless cryptographic analysis by applying ARIA algorithm.

전해질 내 방전 전극의 기포 막 두께에 따른 플라즈마 전력의 변화

  • Yun, Seong-Yeong;Gwon, Ho-Cheol;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.443-443
    • /
    • 2010
  • 액체 표면을 전극으로 하는 플라즈마 방전은 생물학적 살균, 분해 처리 등에 필요한 UV 및 화학적 활성종의 생성에 유리하여 널리 활용되고 있다. 하지만 그 특성 등에 관한 연구는 액체막의 유동 및 기하학적 구조 상 진단의 제한으로 인하여 아직 미비한 상태이다. 전해질 내 방전은 전극 표면의 기포 막 에 인가되고 그 두께에 따라 변한다. 따라서 본 연구에서는 액상 전해질의 인가 전압 및 점성도를 독립적으로 조절하여 기포 막 크기와 인가 전력간의 관계와 이에 따른 전해질 내 플라즈마의 특성이 음극 글로우 방전임을 밝혔다. 실험에서는 전기 전도도 1.6-3.2 S/m의 NaCl 수용액 전해질에 양극성 전극을 삽입하고 350 kHz의 전압을 인가하여 플라즈마를 발생하였다. 인가된 전압은 230 - 280 V이며 전해질의 점성도는 젤라틴을 첨가하여 1E-4-1.1 kg/m${\times}$sec로 조절하였다. 기포 막의 두께 및 변화는 고속카메라를 통하여 관측하였으며 인가되는 전압 및 전류는 고전압 프로브와 전류 프로브를 통하여 관찰하였다. 기포 막은 전극표면에서 막 비등을 통하여 발생됨을 밝혔다. 인가 전력과 손실 열에너지간의 비율에 따라 기포막은 수축과 확장의 진동을 반복하였으며 전기 유체적 모델을 통하여 기포 막의 동적 거동에 따른 플라즈마에 인가된 전력의 변화를 정량적으로 분석할 수 있었다. 기포 막의 평균적인 두께는 인가 전압과 비례하여 약 $150\;{\mu}m$에서 $200\;{\mu}m$로 증가하였으며 진폭은 점성의 증가 시 약 $50\;{\mu}m$에서 $20\;{\mu}m$로 감소하였다. 순간적인 플라즈마 인가 전력은 평균적인 두께에 따른 평균적인 두께에 대해서는 15 - 20 W의 변화를 보였으나 진폭의 감소 시 17 - 70 W의 보다 큰 폭으로 증가하였다. 이를 통하여 점성도가 큰 조건에서 기포 막의 확장이 억제되어 방전이 유지됨을 알 수 있었다.

  • PDF

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.

Development of Time Domain Reflectometry Probe for Evaluation of Copper Concentration in Saline Environment (염수환경에서의 구리 농도 평가를 위한 Time Domain Reflectometry 프로브 개발)

  • Lee, Dongsoo;Lee, Jong-Sub;Hong, Won-Taek;Yu, Jung-Doung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.3
    • /
    • pp.15-24
    • /
    • 2018
  • As electromagnetic waves are affected by electrical conductivity or permittivity, they are widely used to evaluate geotechnical characteristics. In this study, a probe for measuring electromagnetic waves using a time domain reflectometry is manufactured to evaluate heavy metal concentration in saline water. In the experiments, a copper is used as a heavy metal, and a probe is demonstrated with the concentration of copper. Solutions were set for 8 different copper concentration (0, 0.01, 0.05, 0.1, 0.5, 1, 5, 10 mg/L) in saline water with 3% salinity. The probe is coated by electrical insulating materials such as epoxy, top-coat, varnish, acrylic paint, heat-shrinkage tube to measure electromagnetic waves in saline water. The measured signals are compared according to coating material. As results, for probes coated with acrylic paint and heat-shrinkage tube, signal variation is not detected. For epoxy, top-coat, and varnish coated probes, the voltage decreases with an increase of copper concentration. Probes coated by epoxy at once and top coat can estimate under 5 mg/L of copper concentration and the probe coated by epoxy twice can estimate over 5 mg/L of copper concentration. This study shows that the probe using the time domain reflectometry can be used to evaluate the concentration of heavy metal in saline water by coating the probe with insulating material.