누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법 (Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer)

  • 전지용;김영춘;조유환;이근홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

FEM 시뮬레이션을 이용한 2MVA 몰드변압기 권선간 써지전압 분배 해석 기법 연구 (A Surge Voltage Distribution Analysis of 2MVA Cast Resin Transformer Winding with FEM Simulation)

  • 장형택;신판석
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.15-21
    • /
    • 2011
  • This paper presents an analyzing method of the capacitance of the power transformer for initial voltage distribution and insulation design. When a high incoming surge voltage is accidently occurred in windings of transformer, it does not distribute equally in the windings. This phenomenon makes electric field concentration and the insulating material could be break. Initial voltage distribute mostly depends on capacitances between winding to winding or winding to core in the transformer. If the C network can be structuralized into the equivalent circuit model and be calculated each capacitance element value by circuit analysis and FEM(Finite Element Method) simulation program, the transformer designer could know the place where the structure is to be modified or the insulation to be reinforced. This method quickly provides the data of the voltage distribution in each winding to the designer.

열차운행 안정화를 위한 주회로 기기의 고조파 제한장치 개발에 관한 연구 (A Study on the Development of Harmonic Limit Device for Stabilizing Main Circuit Equipment of Train)

  • 김성준;채은경;강정원
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권6호
    • /
    • pp.853-861
    • /
    • 2018
  • 본 논문에서는 전기철도차량이 운행할 때 이상 전압상승에 의한 문제점을 해결할 수 있는 고조파 제한장치의 적용을 제안한다. 운행 중 열차에 전력을 공급하는 교류가선은 25kV/60Hz의 전기를 공급하기 위하여 사용되지만 철도차량 전기장치의 기술발전에 따라 점차 가선에 포함되는 고조파의 크기 및 주파수의 변형이 다양해지고 있다. 최근 열차안전운행에 심각한 문제가 되고 있는 주회로 기기인계기용변압기(Potential Transformer, PT)의 파손이나 주변압기 등의 열손증가는 가선 전원의 고조파로 인한 순간적인 무효전류의 증가로 생기는 현상이다. 주회로 기기의 저주파형 트랜스포머로 고주파수 성분이 유입되면 트랜스 코어의 히스테리시스에 의한 철손 증가 및 기생 커패시턴스에 흐르는 전류가 증가하므로 발열이 발생하게 된다. 이러한 문제 해결을 위해 최근 시퀀스의 조정으로 전력변환 장치의 인위적인 NOTCH OFF가 적용되었다. 그러나, OFF 신호를 받아 제어하는 방식은 지상과 차상 장치의 상호작용으로 동작하므로 불량 발생 시 무효화 되며, 실제 사고가 발생되고 있다. 따라서, 근본적인 문제해결을 위한 방법으로 고조파 전류가 가급적 변압기에 유입되지 않도록 하는 것이 필요하며, 고조파 전류의 유입으로 인해 빈번하게 발생되고 있는 열차사고를 방지하고 안전한 운행을 위해 열차의 실험 분석과 고조파 제한장치의 시뮬레이션을 통한 장치의 타당성 검증을 위한 연구를 수행하였다.

피부과용 $CO_2$레이저시스템의 설계 및 구현 (Design and Implementation of Dermatology $CO_2$ Laser System)

  • Kim, Whi-Young
    • 한국컴퓨터정보학회논문지
    • /
    • 제6권2호
    • /
    • pp.8-13
    • /
    • 2001
  • 최근에 $CO_2$의료용 레이저의 이용이 증가함에 따라 레이저출력의 안정도, 유지와보수의 편리성, 소형화, 저가격화 등이 요구되고 있으며, 이러한 특성을 충족시키기 위해서본 연구에서는 실험실에서 직접 설계ㆍ제작할 수 있는 저속 축류형의 구조를 채택하였다. 그리고 펄스 발생 장치는 SMPS방식, 스위칭 소자는 수십KHz의 스위칭에 적합한 IGBT를 사용하였고 커패시터에 충전된 에너지를 고압ㆍ고주파 펄스 변압기를 사용하여 고압펄스로 변환 후 방전관에 인가하였다. 레이저 출력은 일정한 펄스폭에서 펄스반복율을 변화시킴으로서 제어가 가능하도록 하였다. 반복율은 10Hz~1KHz까지 가변할 수 있도록 설계하였고 최대펄스 전압은 약 20㎸였다. 실험결과 기존의 출력보다 최대 3% 향상을 얻을 수가 있었고. 최대출력은 동작압력 18 Torr에서 23w를 얻었다. 또한, 90˚에서 SCR를 점호하였고 펄스반복률은 60Hz조건에서 한개의 펄스파형을 포착하여 펄스폭(FWHM:Full Width at Half Maxium)을 측정한 결과 약 3㎳을 얻을 수가 있었다.

국내 단상2선식 저압 배전계통 기준임피던스 선정에 관한 연구 (The Determination of Reference Impedance on 1P2W Low Voltage System in Korea)

  • 강문호;송양회;이흥호
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.35-39
    • /
    • 2007
  • 저압 배전계통에서 사용되는 가전제품에 의해 발생되는 전압변동 및 플리커현상을 관리하기 위해 유럽에서는 IEC 기준에 표준화된 시험방법을 규정하고 있다. 본 시험에서는 플리커의 제한치산출시 저압계통의 기준임피던스를 사용하고 있다. 그러나 IEC 기준의 기준임피던스는 230[V]/50[Hz]를 사용하는 저압 배전계통의 임피던스로 국내 저압 배전계통에 그 값을 직접 적용하는 것은 변압기 임피던스, 저압선 경간, 인입선 거리가 상이하기 때문에 불합리하다. 따라서 본 논문에서는 경제성과 확률이론을 바탕으로 국내 단상2선식(1P2W) 저압계통의 기준임피던스를 산정하였으며, 본 연구결과를 기준임피던스로 IEC TR 60725 Ed2에 게재하였다.

전력전자 변압기로 동작하는 저전압 직류배전 기능을 갖는 Quasi Z-소스 AC-AC 컨버터 (A Quasi Z-Source AC-AC Converter with a Low DC Voltage Distribution Capability Operating as a Power Electronic Transformer)

  • 류대현;엄준현;정영국;임영철
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.358-366
    • /
    • 2014
  • This paper proposes a quasi Z-source AC-AC converter with the low DC voltage distribution capability operating as a power electronic transformer. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel, also their output terminal are connected in series. Simple control method of duty ratio was proposed for the in phase buck-boost AC voltage mode and the DC output voltage control. DSP based experiment and PSIM simulation were performed. As a result, the PSIM simulation results were same with the measured results. By controlling the duty ratio under the condition of 100 [${\Omega}$] load, quasi Z-source AC-AC converter could buck and boost the AC output voltage in phase with the AC input voltage, and the same time, the constant DC voltage could be output without affecting the AC output characteristics. And, the DC output voltage 48[V] was constantly controlled in dynamic state in case while the load is suddenly changed ($50[\Omega]{\rightarrow}100[\Omega]$). From the above result, we could know that the quasi Z-source AC-AC converter can act as a power electronic transformer with a low DC voltage distribution capability.

스위치드 변압기 Z-소스 인버터의 출력전압 특성에 관한 연구 (A Study on the Output Voltage Characteristic of Switched Trans Z-Source Inverter)

  • 김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.123-130
    • /
    • 2013
  • This paper proposes the switched trans Z-source inverter(STZSI) which combined the characteristics of the trans Z-source inverter(TZSI) and the switched inductor Z-source inverter(SLZSI). The proposed STZSI has the same performance compared with the SLZSI which is improved the voltage boost performance of the conventional typical X-shaped ZSI, and it has advantage that circuit structure of Z-impedance network is more simple. And, in order to step up the voltage boost factor under the condition of the same duty ratio, unlike the SLZSI adding the inductors and diodes, the proposed method is dune by changing the turn ratio of trans primary winding of Z-impedance network. To confirm the validity of the proposed method, PSIM simulation and a DSP(TMS320F28335) based experiment were performed using trans with turn ratio 1 and 2 under the condition of the input DC voltage VI=50V, duty ratio D=0.1 and D=0.15. As a result, under the same input/ouput condition, the inverter arm voltage stress of the proposed method is reduced to about 15%-22% as compared with typical X-shaped ZSI, and the elements in Z-impedance network of the proposed method is reduced as compared with the SLZSI.

유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구 (A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage)

  • 정성교;이재경;김한도;최대길;강용철;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

과전압에 의한 변압기 철공진 분석 및 방지대책 (Analysis for the Ferroresonance on the Transformer by Overvoltage and Prevention Measures)

  • 윤동현;신동열;차한주
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1543-1550
    • /
    • 2015
  • Ferroresonance is a non-linear vibrational phenomenon that is generated by the electrical interaction of the inductance component with the capacitor component of a certain capacitance as the device of the inductance component such as a transformer is saturated due to the degradation, the waveform distortion of current and voltage, and the oscillation of overcurrent and overvoltage in a system. Recently, ferroresonance was generated from the waveform distortion of current and voltage, or the overvoltage or undervoltage phenomenon caused by the nature of an electrical power system and design technology of the transformer in the three phase transformer system. Hence, in general, ferroresonance analyzed by converting to the LC equivalent circuit. However, in general, the aforementioned analytical method only applies to the resonance phenomenon that is generated by the interaction of the capacitance of bussbar and grounding, and switching as the capacitor component with PT and the transformer as the inductance component in a system. Subsequently, the condition where ferroresonance was generated since overvoltage was supplied as line voltage to the phase voltage and thus the iron core is saturated due to the interconnection between grounded and ungrounded systems could not be analyzed when single phase PT was connected in a ${\Delta}$/Y connection system. In this study, voltage swell in the configuration of grounded circuit of a step-up transformer with the ${\Delta}-{\Delta}$ connection linked to PT for control power and the ferroresonance generated by overvoltage when the line voltage of the ${\Delta}-{\Delta}$ connection was connected to the phase voltage of the grounded Y-Y connection were analyzed using PSCAD / EMTDC through the failure case of the transformer caused by ferroresonance in the system with the ${\Delta}-{\Delta}$/Y-Y connection, and subsequently, the preventive measure of ferroresonance was proposed.