200[W] Half-Bridge LLC Series Resonant Converter for driving LED Lamp (LED 조명장치 구동용 200[W]급 하프브리지 LLC 직렬공진형 컨버터)

  • Han, Woo-Yong;Park, Hyo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4483-4488
    • /
    • 2010
  • In comparison with some other light sources, LED has merits such as long lifetime, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED, which has been applied in display system only, has applied in the field of lighting system. Driving current of power LED has to be controlled below the designed value. In this paper, half-bridge LLC series resonant converter, which has the current limiting function, has been described. Half-bridge LLC series resonant converter allows in relatively wide input voltage and output load range when compared to the other resonant converter. Also, it is possible to reduce a magnetic component, because leakage inductance of transformer is used as a resonant inductance. It has been validated by designing and testing 200[W] half-bridge LLC converter of DC24[V] output voltage for LED lamp driver, which includes a current limiting function and power factor correction(PFC) function.

A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank (저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.562-567
    • /
    • 2020
  • In this paper, this is a study on the correction of protection relays to monitor temporary power facilities for storage tanks especially transformers to block and protect faults such as insulation breakdown. When an abnormality such as a short circuit or a ground fault occurs in the power system, it is important to detect this quickly cut off the device and equipment in which the fault occurred and separate it from the power system to correct the protection relay so that it does not interfere with power supply. In addition the fault current calculation that accurately applies the fault type and the cause of the fault for protection cooperation will be the most important factor in the correction of the protection relay. For protection coordination a study was conducted on the method of coordination for protection of power facility protection for storage tanks such as over current relay, ground over current relay, under voltage relay, and ground over voltage relay applied to temporary.

A Study on Enhancement Method of Hosting Capacity for PV System Based on Primary Feeder Reconfiguration (배전선로 절체에 의한 태양광전원의 수용성 향상방안에 관한 연구)

  • Lee, Myung-Geun;Lee, Hu-Dong;Ferreira, Marito;Park, Ji-Hyun;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.239-249
    • /
    • 2019
  • Recently, the Korean government has implemented a policy to expand renewable energy sources. Large-scale PV systems are being actively interconnected with the distribution system. On the other hand, when a large-scale PV system is installed and operated, the customer voltages could violate the allowable voltage limit due to reverse power flow of the PV system. To overcome these problems, an enhancement method for hosting the capacity of the PV system in a distribution system is being actively conducted. Therefore, to improve the hosting capacity of the PV system, this paper proposes a model of a reconfiguration of the distribution system, which is composed of three sections and three connections based on PSCAD/EMTDC S/W, and proposes an evaluation algorithm for the feeder reconfiguration to maximize an adaption of the PV system. In addition, this paper presents the optimal method of the feeder reconfiguration section to evaluate the maximum capacity of the PV system to keep customer voltages within the allowable voltage limits based on various operation scenarios, such as the capacity of a PV system and section of feeder reconfiguration. From the simulation results based on the PSCAD/EMTDC modeling and evaluation algorithm, it was confirmed that they are a useful and practical tool to enhance hosting the capacity of a PV system in a distribution system.

Developement of Electrical Load Testing System Implemented with Power Regenerative Function (회생전력 기능을 갖는 전기부하시험장치 개발)

  • Do, Wang-Lok;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 2016
  • The electrical load testing system developed from this study was designed to control rated-capacity-testing or variable-load-testing in an active and precise manner and save electric energy during testing, and also to convert the saved electric energy through the electrical load testing system to grid line. As for the device under testing, it was designed to be applied to not only transformer, rectifier, voltage regulator, inverter which require grid voltage source but, also applied to electric power, aerogenerator, photovoltaic, hybrid generator, battery, etc. which do not require grid voltage source. The system was designed to return the power consumed during the testing to the grid line by connecting the synchronizing pwm inverter circuit to the grid voltage source, and was also made to enable the being-tested system from disuse of approximately 93.4% energy when compared to the conventional load testing system which has used the passive resistor.

A Study on Grounding Characteristic Analysis of Large-scaled Apartment Complex Based on PSCAD/EMTDC (PSCAD/EMTDC에 의한 대규모 아파트단지의 접지특성 해석에 관한 연구)

  • Lee, Hu-Dong;Shin, Myeong-Ki;Choi, Sung-Sik;Kang, Min-Kwan;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.650-658
    • /
    • 2017
  • A grounding system in a large-scale apartment complex consists of a TT grounding system when viewed in each building unit, but the characteristics of TN grounding system appears when viewed in the total ground system function. Therefore, this study examined the characteristics of a grounding system in a large-scale apartment complex using design draft, field measurements and PSCAD/EMTDC modeling. This paper proposes an algorithm for fault analysis depending on the grounding system structure in large-scale apartment complexes considering the connection of the underground culvert as well as a design algorithm for each grounding system considering the contact voltage and step voltage. The simulation results based on the proposed modeling and algorithm confirmed that it is useful for analyzing the characteristics of a grounding system in a large-scale apartment complex.

Changes of Properties and Gas Components according to Accelerated Aging Test of Vegetable Transformer Oil (식물성 절연유의 가속열화에 따른 주요 성분 및 물성 변화)

  • Lee, Donmin;Lee, Mieun;Park, Cheonkyu;Ha, Jonghan;Park, Hyunjoo;Jun, Taehyun;Lee, Bonghee
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.18-26
    • /
    • 2016
  • Mineral oil is the most widely used for electrical transformer, though some factors should be considered such as their environmentally harmfulness when it spill and low flash point. To cover these disadvantages, vegetable oil has developed because of its high biodegradability and thermal stability. However, it is necessary that many studies should conduct to reveal the detailed impacts of long-term operation as transformer oil. In this paper, we applied the accelerated aging test which simulate the real transformer circumstances using insulation paper, coil, steel at $150^{\circ}C$, which is higher than normal operation, for 2 weeks. To figure out the oxidation characteristics between mineral oil and vegetable oil test major properties and components such as total acid number, dielectric breakdown and dissolved gas components during that period. As a result of these tests, we found that vegetable oil has higher electric insulation ability than mineral oil though poor total acid number by hydrophile property. Vegetable oil also kept its thermal stability under the given circumstances.

Operational Properties and Microbial Inactivation Performance of Dielectric Barrier Discharge Plasma Treatment System (유전체장벽방전 플라즈마 장치의 조작특성과 살균력)

  • Mok, Chulkyoon;Lee, Taehoon
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.398-403
    • /
    • 2011
  • A dielectric barrier discharge plasma (DBDP) treatment system was fabricated and the optimum operating conditions for the plasma generation were determined in order to explore the potential of cold plasma as a non-thermal proessing technology. The microbial inactivation performance of the system was also evaluated against Staphyloocus aureus. The system consisted of power supply, transformer, electrode assembly and sample treatment plate. The input power was 220 V single phase AC and amplified to 10.0-50.0 kV on a transformer. A pulsed sine wave of frequency 10.0-50.0 kHz was introduced to the electrode embedded in ceramic as a dielectric barrier material in order to generate plasma at atmospheric pressure. Higher currents and consequently greater power were required for the plasma generation as the frequencies increased. A homogeneous and stable plasma was generated at currents of 1.0-2.0, and frequencies of 32.0-35.3 kHz. The optimum electrode-gaps for the plasma generation were 1.85 mm without loaded samples. More power was consumed as the electrode-gaps increased. The practically optimum electrode- gap was, however, 2.65 mm when samples were treated on slide-glasses for microbial inactivation. The maximum temperature increase after 10 min treatment was less than 20$^{\circ}C$, indicating no microbial inactivation effect by heat and thereby insuring a non-thermal method. The DBDP inactivation effect against Staphyloocus aureus increased linearly with treatment time up to 5 min, but plateaued afterward. More than 5 log reduction was achieved by 10 min treatment at 1.25 A.

A Study on the Application of the DVR in AC Electric Traction System (전기철도계통에 순간전압강하 보상장치 적용에 관한 연구)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.95-104
    • /
    • 2003
  • The electric traction systems are quite differ from general power systems which is single-phase and heavy load. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. Among these problems, since steady-state volatge drop is the one of most important factor in electric power quality, many researches about on the compensation of volatge drop by using SVC(Static Var Compensator) and/or STACOM(Static Compensator) have been studied and proposed Also, it is expected that transient voltage drop(voltage sag) could affect the control and safety of high speed traction load. In this paper, voltage sag compensation of AT(Auto Transformer) feeding system are studied The detailed transient models of utility source, scott transformer, AT, and traction load are estabilished. The application of DVR(Dynamic Voltage Restorer) in electric traction system is proposed to compensate the voltage sag of traction network which is occured by the fault of utility source. It can be shown that application of the DVR in electric traction system is very useful to compensate the volatge sag from the result of related simulation works.

An improvement of cycloconverter output using phase shifting filter (상천이 필터를 이용한 싸이클로컨버터 출력의 개선)

  • Kim, Jong-Su;Seo, Dong-Hoan;Kim, Jeong-Woo;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Cycloconverter used as a power conversion device in the speed and torque control system of AC machines has the advantage of a simple control and a large torque at low speed. In addition, because a rectifier, a DC link, and an inverter are not installed, this system is simple and suitable for large power system. If a power conversion device, which is currently used as a propulsion motor of large vessel, is changed into cycloconverter, the system is simplified and then the installation costs can be significantly reduced. However, conventional cycloconverter has the increased harmonics because the power loss is large and the waveform of output voltage is distorted, due to the high-speed switching of power semiconductor devices. In order to improve these shortcomings, this paper describes a phase shifting filter which is composed of two inputs with different phases in the primary side and one output in the secondary one. As the voltage waveforms with two different phases are added and transformed into the secondary side, these outputs are close to sinusoidal waves. Thereby the voltage waveforms, which are applied to the propulsion motors, are improved and total harmonic distortions (THDs) are significantly reduced.

A Study on Novel Step Up-Down DC/DC Chopper of Isolated Type with High Efficiency (새로운 고효율 절연형 스텝 업-다운 DC/DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.82-88
    • /
    • 2009
  • This paper is analyzed for a step up-down DC/DC chopper of high efficiency added electric isolation. The converters of high efficiency are generally made that the power loss of the used semiconductor switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching by partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of the chopper is high. The proposed chopper is also added electric isolation which is used a pulse transformer. When the power conversion system is required electric isolation, the proposed chopper is adopted with the converter system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper are verified by digital simulation and experimental results.