• Title/Summary/Keyword: 전압 검출기

Search Result 323, Processing Time 0.032 seconds

Anti-Slip Control of Railway Vehicle Using Load Torque Disturbance Observer and Speed Sensor-less Vector Control (부하토크외란관측기와 속도센서리스 백터제어를 이용한 철도모의장치의 Anti-Slip 제어)

  • Lee S. C.;Jeon K. Y.;Jho J. M.;Lee S. H.;Kang S. U.;Oh B. H.;Lee H. G.;Han K. H.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.635-642
    • /
    • 2004
  • In electric motor coaches. the rolling stocks move by the adhesive effort between rail and driving wheel. Generally, the adhesive effort is defined by the function of both the weight of electric motor coach and the adhesive effort between rails and driving wheel. The characteristics of adhesive effort is strongly affected by the conditions between rails and driving wheel. When the adhesive effort decreases suddenly, the electric motor coach has slip phenomena. This paper proposes a re-adhesion control based on disturbance observer and sensor-less vector control. The numerical simulation and experimental results point out that the proposed readhesion control system has the desired driving wheel torque response for the tested bogie system of electric coach. Based on this estimated adhesive effort, the re-adhesion control is performed to obtain the maximum transfer of the tractive effort.

All Digital DLL with Three Phase Tuning Stages (3단 구성의 디지털 DLL 회로)

  • Park, Chul-Woo;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.6 no.1 s.10
    • /
    • pp.21-29
    • /
    • 2002
  • This paper describes a high resolution DLL(Delay Locked Loop) using all digital circuits. The proposed architecture is based on the three stage of coarse, fine and ultra fine phase tuning block which has a phase detector, selection block and delay line respectively. The first stage, the ultra fine phase tuning block, is tune to accomplish high resolution using a vernier delay line. The second and third stage, the coarse and fine tuning block, are tuning the phase margin of Unit Delay using the delay line and are similar to each other. It was simulated in 0.35um CMOS technology under 3.3V supply using HSPICE simulator. The simulation result shows the phase resolution can be down to lops with the operating range of 250MHz to 800MHz.

  • PDF

Non-invasive Capacitance Calculation Method for Life Estimation of DC Link Capacitor of Module Type 3-Phase PCS for UIPV System (모듈형 3상 계통연계 태양광 발전용 PCS의 DC link 커패시터 수명진단을 위한 비침투 Capacitance 연산법)

  • Kim, Hong-Sung;Gil, Seo-Jong;Yoon, Yeo-Young;Jeong, Jae-Kee
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.219-221
    • /
    • 2009
  • 태양전지 어레이(PV-array)로부터 발전되는 DC 전력을 AC로 변환시켜 계통으로 발전시키는 역할을 하는 태양광 발전 시스템용 PCS의 스위칭 회로 Topology로는 일반적으로 3상 풀브리지 회로가 사용된다. 이러한 3상 풀브리지 회로 시스템의 수명예측을 위해 DC link 단의 커패시터의 커패시턴스를 계산하여 커패시턴스의 감소정도를 이용하여 전체 시스템의 수명을 예측하게 된다. 이러한 커패시터의 상태를 추정하기 위해서는 시스템을 정지시킨 후 커패시터를 분리하여 커패시턴스를 측정하는 방법, 특정 주파수의 전류(일반적으로 저주파)를 주입하고 주입한 전류의 주파수에 해당하는 전류 및 전압을 검출하여 capacitance 연산하는 방식등이 이용된다. 시스템을 정지시킨 후 커패시터를 분리하여 커패시턴스를 측정하는 방법은 번거로우며, 전류 주입을 이용한 방식은 불필요한 고조파 전류가 계통으로 침투하는 단점을 가진다. 그러므로 본 연구에서는 모듈타입 PCS 이용시 계통으로 고조파 침투가 없는 비침투 커패시턴스 계산 알고리즘을 제안한다.

  • PDF

An Implementation of Active Power Filler that Adopts to a Frequency Variation using the VCGIC(Voltage Controlled Generalized Impedance Converter (전압 제어 임피던스 변환기를 이용한 전원주파수 적응형 능동 전력 필터의 구현)

  • Jang, Mok-Sun;Kim, Sang-Hoon;Lee, Hu-Chan;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.88-95
    • /
    • 2006
  • This paper proposes an analog type Active Power Filter that adapts to the frequency change of a distributed power supply system. The proposed system removes the harmonic currents in the source power by injecting a compensation current that has the same frequency, 180 degree out of phase with the harmonic currents generated by the load. The detection of the harmonics in the source power for creating the compensating current is realized by a PLL(Phase Lock Loop) and a VCGIC(Voltage Controlled Generalized Impedance Converter). The operation of the proposed system is verified by simulation and experiment.

Microwave Characteristics Analysis of TWPD′s Using the FDTD Method (FDTD를 이용한 TWPD의 마이크로파 특성 분석)

  • Gong, Sun-Cheol;Lee, Seung-Jin;Lee, Jeong-Hun;Ok, Seong-Hae;Choe, Yeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.63-71
    • /
    • 2002
  • In this paper, we present microwave characteristics of traveling-wave photodetectors (TWPD) using the finite-difference time-domain method (FDTD). Current and voltage in the time domain are calculated by the FDTD. Also, characteristic impedance and propagation constant in frequency domain are obtained from the time-domain data. As the thickness of i-layer gets thicker and the waveguide width gets narrower, TWPD's show less microwave loss and higher velocity. The 50Ω impedance matching design is achieved for 2.4${\mu}{\textrm}{m}$ waveguide width and 1.2${\mu}{\textrm}{m}$ thickness of i-layer at 100 GHz.

High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults (전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

Development of a Modified Maxwell Bridge for Precise Measurement of a 10 mH, 100 mH Inductance Standards (10 mH, 100 mH 인덕턴스 표준기 정밀측정용 Modified Maxwell Bridge 개발)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Semenov, Yu.P.;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.840-842
    • /
    • 2003
  • 저 주파수에서 인덕턴스 단위(H, Henry)는 전기용량의 단위(F, Farad)로부터 Maxwell bridge 또는 LC를 이용한 resonance 방법으로써 유도가 된다. 이중 Maxwell bridge 방법은 국가의 단위표준을 유지하는 연구소 또는 기관에서 가장 많이 사용되는 "product arm" 형의 bridge로 잘 알려져 있다. 개발된 bridge는 ratio-transformer를 전압공급 쪽(source)과 신호검출 쪽(detector)에 사용하여 종래의 Maxwell bridge 평형조절 시 main balance와 Wagner balance의 2개 과정을 진행하던 것과는 달리 main balance, source balance, detector balance의 과정을 진행함으로서 기존 bridge의 불안정한 ground admittance들의 영향에 의해 나타나는 불확도를 완전히 제거하였다. 한편 개발된 bridge는 10 mH, 100 mH를 10 nF의 전기용량표준기와 $1\;k{\Omega}$, $10\;k{\Omega}$의 저항표준기로부터 유도 되도록 제작되었으며. 10 mH의 경우 $400\;Hz{\sim}5\;kHz$의 주파수 영역에서 약 $2.2{\times}10^{-6}$(k=1)의 불확도로 인덕턴스 단위를 유도할 수가 있게 되었다.

  • PDF

Speed Control of Induction Motor Using the Voltage Type Inverter with Speed Sensorless (속도검출기없는 전압형 Inverter에 의한 유도전동기 속도제어)

  • Seo Young-Soo;Lee Chun-Sang;Hwang Lak-Hoon;Kim Ju-Rae;Cho Moon-Tack
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.430-433
    • /
    • 2001
  • When the vector control, which does not need a speed signal from a mechanical speed sensor, it is possible to reduce the cost of the control equipment and to improve the control performance in many industrial application. This paper describes a rotor speed identification method of induction motor based on the theory of flux model reference adaptive system. The estimator execute the rotor speed identification so that the vector control of the induction motor may be achieved. The improved auxiliary variable of the two model are introduced In perform accurate rotor speed estimation. The control system is composed of the PI controller for speed control and current controller using space voltage vector PWM technique. High speed calculation and processing for vector control is carried out by TMS320C31 digital signal processor. Validity of the proposed control method is verified through simulation and experimental result.

  • PDF

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Analysis of Electrical and Optical Characteristics of Silicon Based High Sensitivity PIN Photodiode (Silicon기반 고감도 PIN Photodiode의 전기적 및 광학적 특성 분석)

  • Lee, Jun-Myung;Kang, Eun-Young;Park, Keon-Jun;Kim, Yong-Kab;Hoang, Geun-Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1407-1412
    • /
    • 2014
  • In order to improve spectrum sensitivity of photodiode for detection of the laser at 850 nm ~ 1000 nm of near-infrared wavelength band, this study has produced silicon-based fast film PIN photodiode and analyzed electrical and optical properties. The manufactured device is packaged in TO-18 type. The electrical properties of the dark currents both Anode 1 and Anode 2 have valued of approximately 0.055 nA for 5 V reverse bias, while the capacitance showed 19.5 pF at frequency range of 1 kHz and about 19.8 pF at the range of 200 kHz for 0 V. In addition, the rising time of output signal was verified to have fast response time of about 30 ns for 10 V. For the optical properties, the best spectrum sensitivity was 0.66 A/W for 880 nm, while it was relatively excellent value of 0.45 A/W for 1,000 nm.