• Title/Summary/Keyword: 전압 검출기

Search Result 323, Processing Time 0.026 seconds

A Study on the Development of a Remote Monitoring Equipment for Ground Fault Current by Lightning Strike (낙뢰에 의한 지락전류 원격 감시장치에 관한 연구)

  • Pyo, Se Young;Kim, Tag Yong;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.783-788
    • /
    • 2020
  • Surges generated by direct strike or induction of lightning, frequent opening and closing of power system breakers, etc. cause excessive overvoltage, which can interfere with normal operation of transformers, circuit breakers, and power equipment. In order to prevent such phenomena, this study goes further from the method of establishing countermeasures by installing lightning arresters on power equipment or lines in parallel, and furthermore, remotely checking the condition of the lightning arrester and preparing immediate countermeasures when an event occurs. The purpose of the study is to prevent damage in advance.

A Study on The Design of China DSRC System SoC (중국형 DSRC 시스템 SoC 설계에 대한 연구)

  • Shin, Dae-Kyo;Choi, Jong-Chan;Lim, Ki-Taeg;Lee, Je-Hyun
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The final goal of ITS and ETC will be to improve the traffic efficiency and mobile safety without new road construction. DSRC system is emerging nowadays as a solution of them. China DSRC standard which was released in May 2007 has low bit rate, short message and simple MAC control. The DSRC system users want a long lifetime over 1 year with just one battery. In this paper, we propose the SoC of very low power consumption architecture. Several digital logic concept and analog power control logics were used for very low power consumption. The SoC operation mode and clock speed, operation voltage range, wakeup signal detector, analog comparator and Internal Voltage Regulator & External Power Switch were designed. We confirmed that the SoC power consumption is under 8.5mA@20Mhz, 0.9mA@1Mhz in active mode, and under 5uA in power down mode, by computer simulation. The design of SoC was finished on Aug. 2008, and fabricated on Nov. 2008 with $0.18{\mu}m$ CMOS process.

ACPF 전해환원 실험 및 결과

  • Park, Byeong-Heung;Hong, Sun-Seok;Heo, Jin-Mok;Lee, Han-Su
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.291-291
    • /
    • 2009
  • 한국원자력연구원의 파이로 실험 시설인 ACPF (ACP Facility)에는 공학규모 전해환원 반응기가 설치되어 공정 대용량화를 위한 연구가 수행되고 있다 본 연구에서는 전해환원 공정의 Scale-up을 위해 기존 반응기를 개선하여 전해환원 실험을 수행한 결과를 담고 있다. 장치의 대형화 빛 원격운전성 향상을 위해 기존의 전해환원 반응기의 상부 플랜지는 보다 간단하게 정리되었으며 염 이송에 의한 고온 조건 노출 시간을 줄임과 동시에 염 재사용을 목적으로 상부 플랜지는 이중으로 설계되었다. 따라서, 반응 종료후 전극이 설치된 상부 플랜지를 들어 올림으로서 반응기를 불활성 분위기로 유지하는 동시에 전해환원 금속전환체를 회수 할 수 있도록 반응기가 제작되었다. 또한, 새로운 반응기는 용융염 내의 강제 유동을 위해 아르곤 버블링이 가능하도록 설계 제작되었다. 새로 제작 설치된 전해환원 반응기를 사용하여 산화물 분말을 혼합하여 준비한 모의 사용후핵연료를 사용하여 전해환원 실험을 수행하였다. 그 결과, 산화물이 충진된 음극의 전영역에서 고루 96% 이상의 높은 금속전환율을 얻었으며 시간에 따라 선택된 FP들의 용융염 내 거동을 측정하였다. 실리더 형태의 음극에서 Cs, Sr 등의 원소들이 용융염으로 시간에 따라 용출되는 것을 확인하였으며 동시에 반응기 재질인 Fe 등도 일부 용융염에서 검출되었다. 아르곤 버블링에 의한 강제 유동은 전압 및 전류 거동에는 큰 영향을 미치지 못하였으나 염의 휘발량을 증가시켜 영조성올 변화시키는 것으로 측정되었다. ACPF의 전해환원 실험결과를 바탕으로 반응기를 상부 기체상과 하부 액체상으로 나누어 전산모사를 수행하였다 상부 기체상은 유입되는 아르곤 기체와 발생되는 산소기체의 흐름을 모사하는 결과를 얻었으며 온도 및 산소의 분압을 계산하였다. 하부 액체상에서는 전기장을 모사하여 전류 밀도 등을 3차원으로 모사하였다.

  • PDF

High Power Factor Single-Phase Active Rectifier for Inverter Air-Conditioner (인버터 에어컨을 위한 고역률 단상능동정류기)

  • 정용채;권경안
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.144-151
    • /
    • 1999
  • 본 논문에서는 IEC 61000-3-2와 같은 고조파 전류 국제규제에 만족하기 위해서 인버터 에어컨을 위한 고역률 단상능동정류가(SAR) [4-6]를 적용하였다. 입력전류의 왜곡을 최소화하고 FA5331, UC3854, ML4821 등과 같은 제어IC를 적용하기 위해서 입력전압 및 전류에 대한 새롭고 적절한 검출회로를 제안하였다. 효율 및 가격의 관점에서 SAR를 인버터 에어컨에 적용하기 위한 두가지 방법이 있다. 이런 두가지 방식에 대해서 수동소자의 선정방법을 제시하였다. 결정된 소자들을 사용하여 SAR 효율의 증가 여부를 확인하기 위해서 손실분석을 행하였다. 3kW급의 이러한 두가지 방식에 대한 프로트형 SAR회로를 제작하고 실험결과를 통해서 역률제어능력을 갖는 회로의 동작과 성능을 확인하였다.

  • PDF

Implementation of a 3 Phase Voltage-Sourced PWM Converter Using the Sensorless Input Current Controller (비검출 전류 제어기를 사용한 3상 전압형 PWM CONVERTER 구현)

  • Kang, Dong-Ku;Lee, Woo-Cheol;Kweon, Seong-Kon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2210-2212
    • /
    • 1997
  • A sensorless input current controller for three phase PWM converter is proposed. A merit of this controller is that sinusoidal input line current, unity power factor, and ripple-free DC voltage can be achieved with low-cost. The paper describes the proposed control strategy and its implementation. Simulation result for the proposed controller is compared with that of the sensor based version.

  • PDF

Speed Control of a Sensorless BLDC Motor (위치 및 속도검출기 없는 BLDC 전동기의 속도제어에 관한 연구)

  • 이홍락;김성환;권영안
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.24-30
    • /
    • 1996
  • BLDC motor is widely used as a servo motor, because it has high efficiency, high power ratio, low inertia, and easy maintenance. However, position and speed sensors generally attached in BLDC motor increase motor cost, and limit environments of application. This study describes a sensorless speed control of sinusoidal BLDC motor using the d-q transformed instantaneous voltage equation, and presents the result of computer simulation. The sensorless algorithm is applied to the casse of a voltage controlled PWM inverter. The result indicates good dynamics and a robust control in cases of a load change and a system parameter variation.

  • PDF

Mono Block Type Portable X-ray Generator (모노 블록형 휴대용 X-선 발생 장치)

  • Oh J.Y.;Sung K.B.;Park J.R.;Kim H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.750-754
    • /
    • 2003
  • 본 논문에서는 X-선 관전류를 직접 검출하여 제어하는 2.4kW(80kv,30mA)급 최소형, 최경량 휴대용 X-선 발생 장치를 제안한다. 본 장치는 X-선발생을 위한 고전압 발생단에 모노탱크 블록 사용하였고, 고주파 고전압용 인버터에는 스위칭 전력소자로서 MOS-FET를 채용, 70kHz로 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. 또한, 설정 관전류에 대한 정밀한 제어를 위하여 2단계 모드로 필라멘트 예열을 행하여 관전류 응답특성을 개선하였으며 제안한 휴대용 X-선 발생장치의 부하변동에 따른 X-선 관전압과 관전류의 개선된 특징을 실험파형을 통하여 입증하였다.

  • PDF

PCB Integrated Pick-up Coil Structure with High Mutual Inductance for Current Measurement of GaN Devices (GaN 소자의 전류 검출을 위한 높은 상호 인덕턴스를 가지는 PCB 내장형 Pick-up Coil)

  • Kim, Kyeong-Mo;Cha, Hwa-Rang;Yang, Si-Seok;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.90-92
    • /
    • 2019
  • 본 논문은 GaN 디바이스를 사용하는 전력변환장치에서 Pick-up coil을 PCB 패턴으로 구현하여 전류를 측정하는 기법에 관하여 제안한다. 기존에 사용되는 PCB 패턴 코일 구조의 경우 PCB 이중층만 구성하여 관통 홀이나 추가공정이 필요함에 비해 본 논문에서 제안한 PCB 패턴 코일 구조의 경우 다층기판을 사용하여 코일을 구성함으로서 기존의 패턴에 비해 높은 상호 인덕턴스 값을 가지게 되고, 코일의 출력 전압값이 높아져 더 높은 감도를 가지게 된다. 또한 PCB 외부의 추가적인 공정 작업이 없이 구성이 되었다. 전류 측정은 코일 뒷단에 적분기를 통합하여 구성하였으며, 시뮬레이션을 통해 전류 측정 성능을 검증한다.

  • PDF

A Study on the Torque Control of Induction Motor using Voltage Source Inverter without speed Sensor (전압형 Inverter에 의한 속도검출기 없는 유도전동기 속도제어)

  • Hwang, L.H.;Kim, J.I.;Jang, B.G.;Lee, S.Y.;Na, S.K.;Kim, J.L.;Lee, C.S.;Cho, M.T.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1130-1132
    • /
    • 2000
  • In this paper, For Control of the speed sensorless induction motor propose the method which is controled the motor by operating two axis current in input current of the inverter. This method determines frequency of inverter in order to stator electromotive force and E/F ratio for the setting magnetic flux, drives for speed control using a voltage power converter of the induction motor by means of voltage fed converter with current control ability.

  • PDF

A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant (발전소 직류전압 전선로 접지검출시스템에 관한 연구)

  • Lee, H.K.;Kim, N.H.;Park, C.H.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF