Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer (피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정)

  • Chu, Sung-Sil;Loh, John-Jk;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a $0.5\;cm\times90\;cm{\times}180\;cm$ acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.

  • PDF

Short-Term Results of Non-Small Cell Lung Cancer with Curative Radiotherapy (비소세포성 폐암의 방사선 치료 성적)

  • Ahn Sung Ja;Park Seung Jin;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.213-218
    • /
    • 1990
  • A retrospective analysis was performed or 102 patients with non-small cell lung cancer who received the curative radiotherapy from August 1985 to October 1988 at the Department of Therapeutic Radiology of Chonnam University Hospital. The follow-up period was ranged from 1 to 37 months and the median follow-up time was 15 months. The acturial 1 and 2 year survival rate of all the patients was $28\%\;and\;5\%$, respectively. The median survival was 10 months for stage II, 6 months for stage IIIA, and 9 for IIIB and the actuarial 2 year survival tate was $12.5\%,\;12.1\%,\;and\;0\%$ respectively. The treatment failure was identified in 32 patients and the locoregional failure was seen in 9 patients ($28\%$) and the distant failure in 23 patients ($72\%$). The initial performance status was related to the survival with statistical significance (p<0.01), but the survival difference by the radiation dose was not statistically significant (p>0.05).

  • PDF

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Radiotherapy Results of Midline Malignant Reticulosis (MMR) (중심선 악성 세망증의 방사선 치료 결과)

  • Yun, Sang-Mo;Kim, Jae-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.291-297
    • /
    • 1996
  • Purpose : This study was performed to evaluate survival, failure patterns, and prognostic factors of MMR patients after radiation therapy. We also discussed the need for chemotherapy. Materials and Methods : A retrospective analysis was done for 23 patients with MMR who were treated with radiation therapy from June 1985 to November 1992. There were 19 male and 4 female patients, The patients' age ranged from 17 to 71 years (median 39 years). Systemic symptoms including fever, weight loss, or malaise were found in $30\%$ of the patients. The nasal cavity was most frequently involved No patients had nodal involvement at diagnosis. There were 2 patients with distant metastasis at presentation. Radiation therapy was delivered five times a week, 1.8 Gy daily, total $45\~54$ Gy (median 50.4 Gy) using 6 MV X-ray No patients received chemotherapy as initial treatment. Results : Overall 5-year and 10-year survival rates were $52.4\%$ and $44.1\%$, respectively. Seventy Percent(12/17) of the patients achieved complete response to radiotherapy, and $29.4\%$ (5/17) achieved partial response. The Patients with complete response showed a better 5-year survival rate than those with partial response ($66.9\%$ vs. $20\%$. p=0.004). Symptom duration before diagnosis, the presence of systemic symptom, and the number of primary sites had no influence on survival. The patterns of failure were as follows: local failure(1), failure in adjacent site(1), local and distant failure(1) distant metastasis(2). and conversion to malignant lymphoma(1). We could not find factors associated with the patterns of failure. Conclusion : The most important facto associated with survival was the response to radiotherapy. Seventeen percent of the patients had distant metastasis, and the salvage after distant metastasis was not successful. However. about $50\%$ of the patients could achieve long-term survival with local radiation therapy alone. Therefore, chemotherapy of MMR should be done after a prospective randomized study for the factors associated with distant metastasis.

  • PDF

Solitary Extramedullary Plasmacytoma of the Head and Neck

  • Park K. R.;Oh W. Y.;Sung J. S.;Suh C. O.;Kim G. E.;Kim B. S.
    • Radiation Oncology Journal
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 1985
  • The details of 5 patients with exramedullary plasmacytoma of the head and neck were reviewed for the period from 1970 to 1984. All patients were presented with localized disease at the time of diagnosis. Out of 5 patients the one treated with surgery alone developed local recurrence and disseminated disease. He died at 3 years and 6 months. Rest of the four were alive with no evidence of the disease. Two patients were treated with radiation therapy alone while other two were treated with surgery and postoperative radiation therapy. Curative radiation therapy is recommanded after the diagnosis is established by biopsy examination.

  • PDF

Dose Evaluation of Childhood Leukemia in Total Body Irradiation (소아백혈병의 전신방사선조사시 선량평가)

  • Lee, Dongyeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Donghyun;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • Total body irradiation in the treatment of childhood leukemia, which is one of the pre-treatment with stem cell transplantation is being used, the current organization using compensators are treated. However, under the terms of the compensator organization long-term impact on the human body, it is difficult to assess directly. In this study, we use the mathematical simulation of radiation exposures body energy and the distance to the crew and the patient (source surface distance, SSD), and patients with tissue compensators change of the distance along the body of the organ doses were evaluated. As a result, the surface dose of energy 4 MV, SSD 280 cm, tissue compensators and the patient when the distance 30 cm 5.84 G / min showed the highest levels. In addition, patients with tissue compensators and the distance apart when 30 cm TBI represents the ideal dose distribution was found.

Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET) (전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정)

  • Hwang, Ui-Jung;Rah, Jeong-Eun;Jeong, Ho-Jin;Ahn, Sung-Hwan;Kim, Dong-Wook;Lee, Sang-Yeob;Lim, Young-Gyung;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Park, Sung-Young;Pyo, Hong-Ryull;Chung, Weon-Kuu
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.60-69
    • /
    • 2010
  • For treatment of Total Skin Electron beam Therapy (TSET), measurement of dose at various conditions is need on the contrary to usual radiotherapy. When treating TSET with modified Stanford technique based on linear accelerator, the energy of treatment electron beam, the spatial dose distribution and the actual doses deposited on the surface of the patient were measured by using EBT2. The measured energy of the electron beam was agreed with the value that measured by ionization chamber, and the spatial dose distribution at the patient position and the doses at several point on the patient's skin could be easily measured by EBT2 film. The dose on the patient that was measured by EBT2 film showed good agreement with the data measured simultaneously by TLD. With the results of this study, it was proven that the EBT2 film can be one of the useful dosimeter for TSET.

Comparison of Distribution following Treatment Method in Total Body Irradiation (전신방사선조사에서 치료방법에 따른 선량분포 특성 비교)

  • 김성규;김명세;신세원
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.21-28
    • /
    • 1995
  • In recent years there has been a growing interest in total body irradiation. For refractory leukemia or lymphoma patients, varions techniques and dose regimens were intridused, including high dose total body irradiation for destruction of leukemic or bone marrow cells and immunosupperression prior to bone marrow transplantation. Accurate provision for specified dose and the desired homogeneity are essential before clinical total body irradiatio. When performed in total body irradiation, the problem obtain uniform uniform dose distribution in brain, neck, lung, umbilicus, pelvis and leg. Authors compared to dose distribution with method 1 and method 1. The method 1 used compensationg filters for homogeneous dose distribution(Minesota University Method). The method 2 used fixing frame made in acryl developing authors. Results were following 1. Method 1 was showed dose distribution from 95.6% to 100%, method 2 showed dose distribution from 95.4% to 100% 2. Method 2 was showed different to 3.4% at skin region and midline in the brain. In the neck, showed different to 1.5%. In the umbilicus, showed different to 2.3%.

  • PDF

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.