• Title/Summary/Keyword: 전선강도

Search Result 75, Processing Time 0.035 seconds

경제적인 송전용철탑설계 2

  • 이재숙
    • 전기의세계
    • /
    • v.17 no.1
    • /
    • pp.32-47
    • /
    • 1968
  • 이글은 전호에 연결되는 글로써 다음과 같이 구성되어 있다. 1. 부재강도 2. 전선배치 3. 기초계산 4. 풍압에 관한 근자의 연구 5. 우리나라 송전선로의 설계개선점 6.결언

  • PDF

Reliance Analysis for Mechanical Characteristics of ACSR Transmission Line due to a Flame (화염에 의한 ACSR 송전선의 기계적 특성에 관한 신뢰성 분석)

  • 김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.138-146
    • /
    • 2003
  • This paper deals with the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include tension load, extension rate and torsion number for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480$\textrm{mm}^2$ which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

A Study on Improvement of Formula for Strength of Anchor Guy (보통지선 강도계산식 개선방안 연구)

  • Wong, Yoon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.394-395
    • /
    • 2007
  • 가공배전선로에 시설되는 지선은 지선이 분담해야 하는 하중에 충분히 견디도록 설계 및 시공되어져야 한다. 따라서 본 논문에서는 전선의 불평형장력을 지지하는 보통지선의 기존 강도계산식의 문제점을 분석하였으며, 이를 개선하기 위하여 지선의 종류에 관계없이 공통적으로 적용 가능한 보통지선 강도계산 기본공식과, 양횡지선, 양종지선, 인류지선 및 각도지선의 분담하중 종류에 따라 각각의 굽힘모멘트 계산식을 개발하여 제시하였다.

  • PDF

An Analysis of the Temporal Pattern according to Hydrologic Characteristics of Rainfall in Urban Area (도시지역에서 강우의 수문학적 특성에 따른 시간분포 분석)

  • Lee, Jung-Sik;Shin, Chang-Dong;Kim, Young-Wook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1830-1834
    • /
    • 2006
  • 본 연구에서는 강우의 수문학적 특성을 고려하여 도시지역에서의 시간분포를 분석하고, Huff의 무차원 누가곡선 및 Yen과 Chow의 무차원 특성변수를 제시하였으며, 강우의 수문학적 특성은 지속기간, 강우의 발생원인(장마, 태풍, 집중호우, 전선형 강우), 강우강도 등으로 분류하였다. 본 연구의 수행으로 인해 얻어진 결과를 요약하면 다음과 같다. 첫째, 국내 도시지역의 단시간 강우의 최대강우강도는 전방위구간에서 발생할 확률이 가장 높게 나타났으며, 둘째, 강우발생원인별 분류에서도 전반적으로 전방위구간에서, 태풍의 경우에는 후방위구간에서 최대강우강도가 발생하였다. 셋째, 평균강우강도이하의 경호우와 평균강우강도이상의 중 호우에서는 전방위구간에서 최대강우강도가 발생하였다. 넷째, 전기간 강우자료를 이용한 기존 연구들의 무차원 누가곡선 및 특성변수와의 비교를 실시하여, 수문학적 특성에 따라 무차원 누가곡선의 위치 및 특성변수의 값에서 차이가 발생한다는 것을 알 수 있었다.

  • PDF

The Effect of Heat Exposure on Fatigue Properties of INVAR Steel Core for STACIR/AW Conductor (증용량저이도송전선(STACIR/AW)용 인바강선의 피로특성에 미치는 경년열화의 효과)

  • Kim, Shang-Shu;Kim, Byung-Geol;Park, Su-Dong;Lee, Hee-Woong;Sin, Goo-Yong;Lee, Dong-Il;Min, Byung-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1274-1277
    • /
    • 2004
  • 최근 에너지 소비구조의 선진화에 따라 전력수요는 매년 10%이상 증가하고 있지만 철탑부지확보 및 환경 문제 둥에 의해 신규 송전선의 건설은 점차 어려워지고 있다. 이에 대한 대책으로 철탑의 교체 없이 송전선의 전류용량간 증가시키는 방안이 우선적으로 고려되어 적용되고 있다. 이미 국내에서도 기존 송전선인 ACSR 전선을 중용량 저이도의 특성을 가진 STACIR/AW(Super Thermal-resistant Aluminum alloy Conductors, aluminum-clad Invar-Reinforced)송전선으로 교체하여 전력 수송량을 증가시키고 있다. STACIR/AW전선은 도체의 내열성을 향상시켜 연속허용온도$(210^{\circ}C)$를 높임으로 전류용량을 증가시키고, ACSR에 사용되는 강심재료인 고탄소강선을 선팽창계수가 낮은 인바강선(INVAR)으로 대체함으로 고온환경에 따른 이도증가를 방지하고 있다. 그러나 STACIR/AW 송전선은 ACSR 송전선에 비하여 연속허용온도가 높고 경간의 거리가 멀기 때문에 열화에 의한 피로특성의 변화 가능성이 높다. 따라서 본 연구에서는 증용량저이도전선의 강심소재인 INVAR/AW강선을 소정의 온도에서 경년 열화하고, 열화시간에 따른 강도와 피로특성의 변화를 조사하여, STACIR/AW전선의 안정적 운전을 위한 재료물성적 관리인자를 도출하고자 하였다.

  • PDF

Numerical Analysis of the Seepage from and Stability of a Mine Waste-dump Slope during Rainfall (강우시 광산폐기물 적치사면의 침투 및 안정성에 대한 수치해석)

  • Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.57-66
    • /
    • 2015
  • A numerical analysis was performed of the seepage from and stability of a mine waste-dump slope in Imgi, Busan, considering rainfall intensity. The 40-45° slope angle of the waste dump is relatively steep, and the depth of the waste dump down to bedrock is 7-8 m. The groundwater level was 6.6 m below the surface. Various laboratory tests on samples obtained from the waste dump were performed to determine the input data for seepage and stability analyses of the waste-dump slope during rainfall. The results of seepage analysis for various rainfall intensities using the SEEP/W program show that the wetting front moved down with increasing rainfall duration. When the rainfall intensity was > 50 mm/ hour and the duration was > 24 hours, the waste dump became fully saturated because the wetting front reached the groundwater level. The results of slope stability analysis coupled with seepage analysis using the SLOPE/W program show that the safety factor of the slope decreased as the wetting front moved down due to rainfall infiltration. After continuous rainfall for 5-6 hours, the safety factor of the slope suddenly decreased but then recovered and converged. The sudden decrease was induced by an increase in pore-water pressure and a decrease in matric suction down to a certain depth as the wetting front approached the potential sliding surface.

electrical shock accident prevention method and risk assesment as grounding type on the low-voltage handhole using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 지중함 접지방법에 따른 전격위험성 평가와 감전사고 예방대책)

  • Han, Woon-Ki;Kim, Jong-Min;Bang, Sun-Bae;Jung, Jin-Soo;Jung, Jong-Woo;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2204-2205
    • /
    • 2008
  • 2005년도에 저압 지중함에서 감전사고가 발생한 후 감전예방을 위한 다양한 개선대책이 현장에 적용되었다. 사고발생 직후에는 지중전선의 접속부에 테이핑처리에 의한 보완조치가 적용되었으며, 그 이후 전선 접속 부를 방수형접속재로 교체하는 작업이 시행되었으며 전선 접속부 위를 감전방지용 절연고무판으로 덮거나 차량의 통행이 없는 일부 지중함의 뚜껑을 절연재질인 고강도플라스틱(FRP)으로 교체하거나 그 이외에 다중접지된 중성선과 지중함의 틀을 본딩하는 개선대책 등이 현장에 적용되었다. 이러한 다양한 개선대책은 지중함에서의 감전사고를 예방하기 위한 것으로 그중 틀접지는 이미 적용된 지중함 내의 접지설비와 중성선이 공통접속된 상태에서 지중함과 맞닿는 틀에 접지도체를 연결하는 것이다. 계통의 중성선을 이용한(TN-C)방식의 틀접지는 효과가 있으나 뚜껑부분의 진동방지를 위하여 삽입한 고무패킹은 성능저하를 일으키므로 그에 대한 대책이 필요하였다.

  • PDF

A Study on the Life-Time Estimation of ACSR Transmission Line Due to a Flame (화염으로 인한 ACSR 송전선의 수명예측에 관한 연구)

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.77-84
    • /
    • 2005
  • The considerations for reminder life of transmission line is gradually higher. It is requisite for investigation of ACSR life to test tensile load of ACSR as a fundamental data. It is vary important to analysis correlations between results of tensile load testing and elapsed years. Estimation of ACSR life can be obtained by statistics processing using mechanical experimental results. It is a general method to use regression analysis as a statistics processing technique. In this paper, we did experiment on tensile strength of ACSR by using a new and due to flame for artificial fire, and gathering due to a flame. The limit of life estimation is decided by basic line using twenty percentage reduction of rate tensile strength. This basic line is like to results of Canada Ontario Hydro-research. There are $480[mm^2]$ ACSR which are experimented on this study.

Assessment of material analysis for out-door used corss-linked polyethylene insulated copper wire-waterproof for 22.9kV-y (특고압 수밀형 가교폴리에틸렌절연 동전선(OC-W) 시험평가기술)

  • Soh, Jin-Joong;Shim, Dae-Sup;Yoon, Kee-Taek
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.507-510
    • /
    • 2004
  • 염해지역 배전선로의 나선 사용에 따른 안전사고방지 및 전력공급신뢰도 향상을 위하여 경동선 도체에 수밀 컴파운드를 충진하고 흑색의 가교폴리에틸렌으로 압출한 절연전선으로 염해지역의 특별고압 가공전선로에 사용하며 내부식성, 수밀성 및 전기 특성이 우수하다. 따라서 본 평가기술에서는 내트래킹, 인장강도, 우수침입방지성, 침적성, 통전내부식성, 교류파괴전압, 박리성, 밀착도 등의 주요한 시험에 대한 시험방법을 검토하고, 시험에 적용하여 시험 시 문제점을 도출하고 시험방법을 정립하고자 한다.

  • PDF

The Development of ACNR Conductor(II) - Electric Properties (ACNR가공송전선의 개발(II) - 전기적 특성)

  • Kim, Shang-Shu;Kim, Byung-Geol;Lee, Hee-Woong;Park, Joo-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.629-630
    • /
    • 2005
  • ACSR(Aluminum Conductor Steel Reinforced)가공송전선은 교류전류의 흐름에 의하여 코어 (Core)부에 자기장이 발생되어 전력손실을 발생시킨다. 이로 인한 전력손실을 최소화 하는 방법으로는 코어의 재질을 자성체인 고탄소강선 대신에 비자성강으로 교체하는 방법이 있다. 본 연구에서는 기존의 고탄소강선 대신에 고강도 비자성강을 코어(Core)에 적용한 ACNR(Aluminum Conductor Nonmagnetic Steel Reinforced) 가공송전선을 개발하였다. ACNR 가공송전선의 전기적 특성시험에서 약 9%정도의 손실저감효과를 나타내었다.

  • PDF