Removal of Ring Artifact in Computed Tomography (전산화단층촬영장치에서 링 아티팩트 제거)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.403-408
    • /
    • 2015
  • Hard X-ray has been widely used in medical and industrial fields because it can be applied to observe the inside of a sample. Computed tomography provides sectional images of the sample through the reconstruction of the projection images. The quality of sectional images strongly depends on that of projection images. Ring artifact appeared on the seconal image can be made by the abnormal pixels of the detector used. In this study, we examine the ring artifact ratio in the circle phantom as a function of detection error of the detector used in computed tomography. The ring artifact increased with the increment of detection error under parallel and fan beam geometries and strongly increased near the center of rotation. The corrections, dead pixel and flat field corrections, for the images taken with the detector are required before the image reconstruction process to reduce the ring artifact in the computed tomography.

A study on the utilization of CT equipments (전산화 단층촬영 장치의 이용 실태에 대한 조사)

  • Cho, Pyong-Kon;Oh, Yu-Whan;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • This study was conducted to investigate the patient exposure dose during a CT examination and the present position in utilization of the CT equipments. To this end Questionnaire were sent out to 278 medical facilities registered at Korea Hospital Association and replies of 161 medical facilities were analyzed. The results were as follows ; 1) The distribution of CT examination was. Brain 40.7%, Abdomen 27.8%, Chest 15.7%, Spine 4.8%, Pelvis 4.1%, PNS 3.2%, Facial bone 2.5% and Extremity 1.1% respectively. 2) The statistics for dose index according to each part of examination were Brain 38.0mGy, Abdomen 12.0mGy for adults : Brain 13.6mGy, Abdomen 6.2mGy for infant. Our surveyed dose index appeared lower than the IAEA recommends. 3) Most medical facilities have selected the parameters for radiographic exposure in the range of $100{\sim}120kVp,\;100{\sim}250mA\;and\;1{\sim}2$ seconds.

Development of Tomographic Scan Method for Industrial Plants (산업공정반응기의 감마선 전산 단층촬영기술 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho;Kwon, Taek-Yong;Cho, Gyu-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.20-30
    • /
    • 2010
  • In this paper, a new tomographic scan method with fixed installed detectors and rotating source from gamma projector was presented to diagnose the industrial plants which were impossible to be examined by conventional tomographic systems. Weight matrix calculation method which was suitable for volumetric detector and statistical iterative reconstruction method were applied for reconstructing the simulation and experimental data. Monte Carlo simulations had been performed for two kinds of phantoms. Lab scale experiment with a same condition as one of phantoms, had been carried out. Simulation results showed that reconstruction from photopeak counting measurement gave the better results than from the gross counting measurement although photopeak counting measurement had large statistical errors. Experimental data showed the similar result as Monte Carlo simulation. Those results appeared to be promising for industrial tomographic applications, especially for petrochemical industries.

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

자기 공명 영상술의 원리와 최근 연구 현황

  • 조장희;김영근
    • 전기의세계
    • /
    • v.38 no.8
    • /
    • pp.19-25
    • /
    • 1989
  • 현재 전세계적으로 퍼져있는 NMR-CT 시스템의 수를 살펴보면 약 370여기가 설치.운영되고 있으며 앞으로 계속 늘어날 전망이다. 국내에서는 1988 한국과학기술원과 금성통신에 의해 자체 개발된 2.0 Tesla 강자장 시스템이 최초로 서울대학병원에 설치 가동된 이래 여러병원에서 시스템들이 설치중에 있다. 첨단의로 진단장치로서의 핵자기 공명 영상법은 그 영상을 통하여 기존의 진단 장치보다 우월함을 증명하고 있으며 초음파 검사나 동위원소 검사 및 X선 전산화 단층 촬영술들을 장점을 두루 지니면서 그 영상법의 다양성 때문에 앞으로의 연구 및 발전에 대한 전망은 아주 밝다고 할 수 있다. 따라서 앞으로의 종합 영상 의료 진단 장치는 이 NMR-CT가 중심이 되어 발전할 것이라고 단언해도 무리한 생각은 아닐 것이다.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Effect of Botulinum Toxin type A and Occlusal Splint on Masseter Muscle Evaluated with Computed Tomographic Measurement (전산화 단층촬영으로 평가한 교근에 대한 보툴리눔 A형 독소주사와 교합안정장치의 효과)

  • Jang, Hee-Young;Kang, Seung-Chul;Kim, Seong-Taek;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.247-255
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of botulinum toxin type A on masseter muscle atrophy and the extent of masseter muscle affected from the injection site in relation to injection dose, with and without occlusal splint therapy through computed tomographic measurement. 32 volunteers were divided into four groups - group 25U (injection dose of 25 unit), group 25Us (injection dose of 25 unit with occlusal splint), group 35U (injection dose of 35 unit), group 35Us (injection dose of 35 unit with occlusal splint). Each group consisted of 8 people. 3 positions (position 1, 2, 3 - 10mm, 20mm and 40mm from the inferior border of the mandible, respectively) were selected for the evaluation of the masseter muscle change. The following results were obtained. 1. The thickness and the cross-sectional area of the masseter muscle had reduced in all groups except for the right side thickness at position 3 of group 25U and group 25Us, and the right side thickness as well as the left side cross-sectional area at position 3 of group 35Us. In group 35Us, the thickness and the cross-sectional area of the masseter muscle had reduced significantly in all positions (P < 0.05). 2. There was no significant difference in the masseter muscle change between the injection dose of 25unit and that of 35unit. 3. The groups with occlusal splint showed greater reduction of the masseter muscle thickness than the other groups (P < 0.05). From the above results, botulinum toxin type A injection together with occlusal splint therapy in the treatment of masseter muscle hypertrophy would be clinically effective.

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

A Study about Amendment of Safety Control of Computed Tomography (전산화단층촬영용장치의 안전관리 개정에 관한 연구)

  • Kim, Kyotae;Heo, Yeji;Oh, Kyungmin;Noh, Sicheul;Kang, Sangsik;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.383-387
    • /
    • 2013
  • Diagnostic imaging systems play a critical role in obtaining anatomical images, which increases the frequency of inspection all over the world. However the likelihood that patients are exposed to relatively high radiation dose increases, which may lead to an increase of patient dose due to unnecessary radiation exposure unless appropriate management is accompanied. Thus the revised edition of IEC 60601-2-44 which is constancy tests for CT equipment which is designated as special medical equipment and is subject to safety management was studied. The results suggested the 3rd has been revised rationally in order to overcome the limitations in the 2nd by adopting clear and enhanced references, which implies the replacement of IEC 60601-2-44 2nd edition with IEC 60601-2-44 3rd will prevent the patients from the harm from improper medical equipment.