• 제목/요약/키워드: 전산화단층촬영 영상

검색결과 505건 처리시간 0.026초

두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도 (ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION)

  • 김애지;조봉혜;나경수
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현 (An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound)

  • 박형재;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.516-519
    • /
    • 2001
  • 환자를 진단하는데 있어 중풍, 고혈압, 동맥경화, 고지혈증 등 혈관 질환에 대해서 혈류에 관한 정보는 매우 중요하다. 초음파를 이용하여 혈류 속도를 측정하는 방법에는 연속 도플러 시스템과 펄스 도플러 시스템으로 나뉘어진다. 펄스 도플러 시스템은 혈류의 위치정보를 얻을 수 있지만, 연속 도플러 시스템에 비해 하드웨어적으로 복잡하고 신호대 잡음비가 낮으므로 본 연구에서는 신뢰적인 정보를 얻을 수 있는 연속 도플러 시스템을 이용하였다. 본 시스템은 크게 아날로그 부와 디지털 부로 나뉘어진다. 아날로그 부는 초음파 신호의 발생부, 초음파 센서로 수신된 신호를 증폭하는 증폭부와 혈류의 도플러 신호를 검출하는 복조부, 잡음 제거를 위한 필터부분으로 구성되어 있다. 디지털 부는 검출된 아날로그 신호를 디지털 신호로 변환하는 부분, 디지털 신호처리 부분 그리고 개인용 컴퓨터(Personal Computer)와 통신하는 부분으로 구성된다. 본 연구에서는 효율적인 초음파 혈류 속도 측정 시스템을 구현함으로써 환자의 혈류 정보를 실시간으로 인을 수 있으므로 뇌혈류 측정 등에 사용되는 전산화 단층 환영장치(Computered Tomography), 자기 공명 영상 촬영장치(Magnetic Resonance Imaging)와 같은 장비와 더불어 보다 정확한 진단을 하는데 유용하다.

  • PDF

컬러 도플러 초음파를 이용하여 발견한 견부 모기질세포종: 증례보고 (Pilomatricoma of the Shoulder Easily Identified by Color Doppler Ultrasound: A Case Report and Review of Literature)

  • 서준영;김태정;김상림;남광우
    • 대한정형외과 초음파학회지
    • /
    • 제6권1호
    • /
    • pp.10-14
    • /
    • 2013
  • 모기질세포종은 모발의 기질세포로부터 발생하는 양성 피부종양이다. 이것은 주로 두 경부 및 상지에 호발한다. 수술 전 진단의 정확성은 낮으며 단순방사선 검사만 시행한 후 절제생검을 하기도 한다. 저자들은 컬러도플러 초음파를 이용해서 쉽게 진단할 수 있었던 견부에 발생한 모기질세포종에 대해 보고하고자 한다. 초음파를 이용한 진단은 비용효과적인 측면 뿐만 아니라 종양의 내부에 대해 자세한 정보를 알 수 있다는 점에서 전산화 단층촬영이나 자기공명영상보다 더 손쉽고 유용한 진단방법으로 생각된다.

  • PDF

MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계 (An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode)

  • 오종갑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.315-321
    • /
    • 2011
  • 본 연구는 검사 기법에 따른 영상의 질과 방사선 피폭의 정도를 제시하여 검사자가 받는 방사선 피폭을 저감시키는 데 목적이 있다. 관상동맥 전산화 단층 혈관조영(Coronary CTA, coronary computed tomography angiography) 검사자를 대상으로 SnapShot Pulse의 전향적 동조화 기법과 SnapShot Segment의 후향적 동조화 기법으로 coronary CTA 검사에서 검사자가 받는 단면 피폭선량(CTDIvol, volume computed tomography dose index), 총 피폭선량(dose-length product; DLP)을 각각 측정하였다. 또한, Coronary CTA 촬영조건을 동일하게 팬텀을 이용하여 CT감약계수, 노이즈 및 균일도, 공간분해능을 측정하였다. 연구 결과 두기법에서 CT감약계수, 노이즈 및 균일도, 공간분해능의 질적 수준이 비슷하게 나타났으며, CTDIvol, DLP는 SnapShot Segment의 후향적 동조화 기법에 비해 피폭선량이 약 37.5%, 40.3% 감소되었다. 임상에서 coronary CTA 검사 시 SnapShot Pulse의 전향적 동조화 기법을 적극 채택하여 검사자가 받는 방사선 피폭을 감소시키기 위한 노력이 절실히 요구된다.

안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가 (Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan)

  • 문세영;홍상우;서지숙;김영범;곽완신;이성영;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

상대정맥에 발생한 평활근육종의 수술 - 1례 보고 - (SVC Syndrome Caused by Leiomyosarcoma of SVC - A Case Report -)

  • 손영상;류세민;손호성;조원민;황재준;최영호;김학제;심재정;조성준
    • Journal of Chest Surgery
    • /
    • 제35권3호
    • /
    • pp.235-238
    • /
    • 2002
  • 상대정맥 증후군을 유발하는 여러 가지 원인들 중에 상대정맥 자체에서 발생하는 종양은 매우 드물다. 저자들은 상대정맥에 발생하여 혈류 장애를 초래한 평활근육종 1례를 수술 치료 하고 추적 관찰하여 보고하는 바이다. 환자는 39세 여자 환자로 내원 전 6주 동안의 안면 부종 및 두통을 주소로 내원하였다. 내원 시 안면 부종과 더불어 경부 및 상지의 정맥 충혈을 보였고, 중심정맥압은 측정 치 않았으나 경부 및 상부 흉벽의 측부혈행로도 보였다 단순 흉부 사진 상 우상부 종격동의 연부조직 종괴의 음영을 확인하고 흉부 전산화 단층 촬영 및 상대정맥 조영술을 시행하여 혈류장애를 초래하고 있는 커다란 종괴를 확인하였다. 수술은 흉골 정중 절개를 통해 체외 순환의 도움 하에 상대정맥을 종절개 하였다. 종양은 무명정맥입구에서 시작해서 우심방-상대적맥 접합부 약 1-2cm 우심방 안까지 위치하고 있었다. 먼저 종괴를 제거한 후 우경정맥의 혈전은 풍선 카테타를 이용하여 완전히 제거하였다. 조직검사상 상대정맥에서 발생한 평활근육종을 진단하였고, 수술 후 14개월 추적 관찰하는 중에 별다른 문제는 없었으며, 상대정맥 조영에서도 정상적인 소견을 보였다.

Cone beam형 전산화 단층촬영장치를 이용한 설공의 해부학적 구조 (Anatomical structure of lingual foramen in cone beam computed tomography)

  • 기민우;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Purpose: To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Materials and Methods : Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. Results: In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03±0.08, and both lateral lingual foramina was 0.20±0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9mm±0.28, right lateral lingual foramen was 0.92mm±0.23, and left lateral lingual foramen was 0.88mm±0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Conclusion : Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  • PDF

전산화 단층촬영을 이용한 법랑모세포종의 방사선학적 연구 (A radiologic study of ameloblastoma using computed tomography)

  • 박혁;정호걸;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제35권2호
    • /
    • pp.77-82
    • /
    • 2005
  • Purpose : To reveal what is the distinct differential diagnostic differences between unicystic ameloblastoma and solid or multicystic ameloblastoma. Materials and Methods : 56 cases of ameloblastoma were retrospectively reviewed and evaluated among the patients who had taken CT scans at the department of Oral & Maxillofacial Radiology in Yonsei University Dental Hospital from January 1996 to December 2003. Results : In 56 cases, 21 cases $(37.5\%)$ were unicystic ameloblastoma, 35 cases $(62.5\%)$ were solid or multicystic ameloblastoma. Only 1 case $(4.8\%)$ of unicystic ameloblastoma and 4 cases $(11.4\%)$ of solid or multicystic ameloblastoma were occurred in maxilla. 13 cases $(61.9\%)$ of unicystic ameloblastoma were observed as unilocular, and 8 cases $(38.1\%)$ as lobulated. 5 cases $(14.3\%)$ of solid or multicystic ameloblastoma were observed as unilocular, 13 cases $(37.1\%)$ as lobulated, and 17 cases $(48.6\%)$ as multilocular. Tn the results from the measurements after correction of the buccolingual widths and heights to the mesiodistal lengths, there is a statistically significant difference between unicystic ameloblastoma and solid or multicystic ameloblastoma in ANCOVA test (p<0.05). Hounsfield units in the lesion were $24.9{\pm}8.8\;HU$ in unicystic ameloblastoma, $31.2{\pm}11.5\;HU$ in solid or multicystic ameloblastoma. There is no statistically significant difference (p>0.05). Conclusion : Characteristic differences between unicystic ameloblastoma and solid or multicystic ameloblastoma is that there is higher prevalence of solid or multicystic ameloblastoma that have lobulated or multilocular patterns. To measure the Hounsfield units in the lesion is helpful, but it is not a differential diagnostic point between unicystic ameloblastoma and solid or multicystic ameloblastoma.

  • PDF

Cone beam형 전산화단층촬영장치를 이용한 하악 제1대구치 근심 치근의 danger zone에 관한 연구 (Evaluation of danger zone in mesial root of mandibular first molar by cone beam computed tomography (CBCT))

  • 장유리;최용석;최기운;박상혁
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.103-110
    • /
    • 2007
  • Purpose: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT (cone-beam computed tomography) to avoid the risk of root perforation. Materials and Methods: 20 mandibular first molars without caries and restorations were collected, CT images were obtained by CBCT ($PSR9000N^{TM}$, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea), Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured, Results: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm, Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm, The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D, MB-D is thinner than ML-D although the differences is not significant. Conclusion: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.

  • PDF

CT 영상에서 뇌출혈의 자동인식 (Intracerebral Hemorrhage Auto Recognition in Computed Tomography Images)

  • 최석윤;강세식;김창수;김정훈;김동현;예수영;고성진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권2호
    • /
    • pp.141-148
    • /
    • 2013
  • CT 검사 시 뇌출혈의 부위는 심각한 정도에 따라 인지하기 어려운 경우도 있으며, 응급상황에서 숙련이 되지 않은 의료진에게는 부담을 준다. 응급상황에서 검사와 동시에 뇌출혈부위를 자동으로 빨리 파악하고 정량적인 정보를 제공하는 보조적인 역할은 필요하며, 컴퓨터를 이용한 자동 검출 및 인식 시스템은 출혈부위 진단에 매우 큰 도움을 줄 수 있다. 본 연구에서는 출혈부위를 문턱치값 처리, 모폴로지 연산, 원형률 계산을 접목하여 뇌 출혈부위의 자동검출에 성공하였고 검출 후보군에서 잘 못 선정된 영역을 판정하기위한 주성분분석을 이용한 분류기 개발에 성공하였다. 개발된 시스템을 응급상황의 뇌출혈 환자에게 적용한다면 의료진에게 수술계획을 위한 유용한 정보가 될 것으로 사료된다.