• Title/Summary/Keyword: 전산화단층촬영 영상

Search Result 505, Processing Time 0.023 seconds

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Clinical and Radiological Findings of Coronavirus Disease 2019 Pneumonia: 51 Adult Patients from a Single Center in Daegu, South Korea (Coronavirus Disease 2019 폐렴의 임상적, 영상의학적 소견: 대구의 단일 기관에서 51명의 성인 환자를 대상으로 한 분석)

  • Seung Eun Lee;Young Seon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.591-603
    • /
    • 2020
  • Purpose The purpose of this study was to describe the clinical features and chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) pneumonia. Materials and Methods An Institutional Review Board-approved retrospective review was performed for 51 laboratory-confirmed COVID-19 pneumonia patients. Patients were divided into two groups depending on their clinical status: mild and severe. Clinical characteristics and chest CT findings were compared between the two groups. Results Among the 51 patients (22 men, 29 women; mean age, 56.5 ± 16 years; range, 22-88 years), 37 (72.5%) were in the mild group and 14 (27.5%) were in the severe group. The patients in the severe group (68.7 ± 12.5 years) were older than the patients in the mild group (51.8 ± 14.9 years, p < 0.001). Premorbid conditions and decreased lymphocyte counts were more often observed in the severe group than in the mild group (71% vs. 41%, p = 0.049 and 86% vs. 32%, p = 0.001, respectively). On chest CT, most patients exhibited a mixed ground-glass opacification (GGO) with consolidation (76%) or a GGO (22%) pattern. The majority of lesions were predominantly bilateral in the lower lung with a posterior, peripheral distribution. The patients in the severe group had higher severity scores than those in the mild group. Conclusion Patients with laboratory-confirmed COVID-19 pneumonia have typical chest CT findings that provide important information regarding expected disease severity.

MR Images of Infarction of Wandering Spleen Associated with Intestinal Non-rotation (장 회전 이상과 함께 발생한 부유비장 경색의 자기공명영상에서의 소견: 증례 보고)

  • Kim, Eugene;Kim, Mi Young;Kim, Yeo Ju;Kim, Youn Jeong;Kim, Woo Chul;Suh, Chang Hae;Choi, Suk Jin;Cho, Jae Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.253-257
    • /
    • 2014
  • Wandering spleen is a rare clinical condition caused by lax splenic suspensory ligaments. The laxity of ligaments causes torsion of splenic vascular pedicle. CT scan of a 7-year-old girl with abdominal pain showed a non-enhancing lobular mass in lower abdomen. Small bowel loops were located at the right-sided abdomen and colonic loops at the left-sided abdomen. MRI scan showed non-enhancing heterogeneous mass with twisted vascular pedicle. To our knowledge, only a few cases have been reported about wandering spleen diagnosed on MRI.

Radiotherapy Treatment Planning in Head and Neck Cancer by CT-Reconstruction (CT 재구성에 의한 두경부 종양의 방사선 치료 계획)

  • Ryu, Sam-Uel;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.141-148
    • /
    • 1987
  • The ultimate goal of radiotherapy is to result in complete local control of tumor while sparing the surrounding normal tissues as much as possible. Since the development of CT in 1970s, patient's anatomical normal tissues and the site and extent of infiltration of tumor were identified almost accurately. In addition, the isodose distribution of delivered radiation to target tumor was shown in each cross-section. In the treatment planning of head and neck cancers, CT-reconstruction provided almost 3-dimensinonal inter-relationship between tumor and normal tissues. The utilization of imaging system of the CT scanner made it possible to illustrate in superposition the patient structure image, the radiation beams, and the isodose distributions. Thus it was possible to deliver radiation enough to control the local disease, and to avoid unnecessary administration of radiation to normal tissue such as spinal cord. CT-reconstructed image in axial, sagittal, and coronal planes suggested 3-dimensional radiotherapy treatment planning be possible and practical instead of conventional 2-dimensional planning at coronal plane.

  • PDF

A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination (전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구)

  • Choi, Min-Hyeok;Jang, Ji-Sung;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.105-111
    • /
    • 2019
  • A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.

A Case of Acute Lung Injury Complicated by Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma (간세포암의 간동맥 화학색전술 후 발생한 급성 폐손상 1예)

  • Cho, Se-Haeng;Kim, Joo-Hang;Kim, Byung-Soo;Jang, Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.781-786
    • /
    • 1995
  • Transcatheter arterial chemoembolization(TACE) was performed in a 61 year old male patient with hepatocellular carcinoma with 10 cc of Lipiodol and 50 mg of doxorubicin. Three days later, he complained of dyspnea and dry cough. The arterial blood gas study revealed moderate hypoxemia and hypocarbia. The chest PA showed acute pulmonary edema with bilateral pleural effusion. To rule out the possibilities of acute respiratory failure caused by infection, pulmonary embolism or congestive heart failure, we performed several laboratory studies. The blood and sputum culture studies revealed negative results for bacterial growth. The echocardiogram was normal. The abdominal CT scan and MR imaging revealed no thrombus or mass lesion in the inferior vena cava. So we concluded pulmonary oil embolism induced by lipiodol as the cause of acute lung injury. Four weeks later, clinical symptoms and chest x-ray were markedly improved with conservative care. We report a case of acute lung injury after TACE with lipiodol and doxorubicin, with review of literatures.

  • PDF

Application of Three-Dimensional Printed Models in Congenital Heart Surgery: Surgeon's Perspective (선천성 심기형의 수술에 있어서 삼차원 프린팅 모델의 적용: 심장외과의사의 관점)

  • Hyungtae Kim;Ki Seok Choo;Si Chan Sung;Kwang Ho Choi;Hyoung Doo Lee;Hoon Ko;Joung-Hee Byun;Byung Hee Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.310-323
    • /
    • 2020
  • To treat congenital heart disease, it is important to understand the anatomical structure correctly. Three-dimensional (3D) printed models of the heart effectively demonstrate the structural features of congenital heart disease. Occasionally, the exact characteristics of complex cardiac malformations are difficult to identify on conventional computed tomography, magnetic resonance imaging, and echocardiography, and the use of 3D printed models can help overcome their limitations. Recently, 3D printed models have been used for congenital heart disease education, preoperative simulation, and decision-making processes. In addition, we will pave the way for the development of this technology in the future and discuss various aspects of its use, such as the development of surgical techniques and training of cardiac surgeons.

How to Determine the Moving Target Exactly Considering Target Size and Respiratory Motion: A Phantom Study (종양의 움직임과 호흡주기에 따른 체적 변화에 대한 연구: 팬텀 Study)

  • Kim, Min-Su;Back, Geum-Mun;Kim, Dae-Sup;Kang, Tae-Yeong;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.145-153
    • /
    • 2010
  • Purpose: To accurately define internal target volume (ITV) for treatment of moving target considering tumor size and respiratory motion, we quantitatively investigated volume of target volume delineated on CT images from helical CT and 4D CT scans. Materials and Methods: CT images for a 1D moving phantom with diameters of 1.5, 3, and 6 cm, acryl spheres were acquired using a LightSpeed $RT^{16}CT$ simulator. To analyze effect of tumor motion on target delineation, the CT image of the phantoms with various moving distances of 1~4 cm, and respiratory periods of 3~6 seconds, were acquired. For investigating the accuracy of the target trajectory, volume ratio of the target volumes delineated on CT images to expected volumes calculated with diameters of spherical phantom and moving distance were compared. Results: Ratio$_{helical}$ for the diameter of 1, 5, 3, and 6 cm targets were $32{\pm}14%$, $45{\pm}14%$, and $58{\pm}13%$, respectively, in the all cases. As to 4DCT, RatioMIP were $98{\pm}8%$, $97{\pm}5%$, and $95{\pm}1%$, respectively. Conclusion: The target volumes delineated on MIP images well represented the target trajectory, in comparison to those from helical CT. Target volume delineation on MIP images might be reasonable especially for treatment of early stage lung cancer, with meticulous attention to small size target, large respiratory motion, and fast breathing.

  • PDF

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Bronchopleural Fistula after Surgery: Therapeutic Efficacy of Bronchial Occluders (수술 후 기관지늑막루: Bronchial Occluder Device의 치료 효과)

  • Young Min Han;Heung Bum Lee;Gong Yong Jin;Kun Yung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.371-381
    • /
    • 2021
  • Purpose To evaluate the usefulness and effectiveness of bronchial occluders in the treatment of postoperative bronchopleural fistula (BPF). Materials and Methods The subjects of the study were six out of seven postoperative BPF patients who underwent surgery due to tuberculosis or lung cancer between 2009 and 2019. Each patient had a bronchial occluder inserted to treat BPF that occurred after surgery. Of the six patients, five had lung cancers and one had tuberculosis. Five were male and one was female; their ages ranged from 59 to 74 years, with an average of 69 years. The diagnosis of BPF was based on findings from bronchoscopy and CT, and treatment was initiated approximately 1 to 2 weeks after diagnosis. The technical and clinical success of the bronchial occluders in the treatment of BPF was evaluated. The study assessed the postoperative clinical effects of the occluders, survival duration, and additional treatments. Results All six patients were successfully treated. Clinical success was achieved in five patients, while partial clinical success was achieved in one; there was no clinical failure. No complications during the migration of the device or device perforations were observed. Two patients were diagnosed with BPF by CT, while four were diagnosed by bronchoscopy. Lobectomy, bilobectomy, and pneumonectomy were performed on two patients each. The periods between surgery and diagnosis ranged from 1 to 34 months; the average was 10 months. Four patients (59-103 days; an average of 80.5 days) died and two (313 days, 3331 days) survived. The causes of death were aggravation of the underlying disease (n = 2), pulmonary edema and pleural effusion (n = 1), and pneumonia (n = 1). Additional catheter drainage was performed in one patient, and a chest tube was maintained in two patients. Conclusion Bronchial occluders are useful and effective in the treatment of BPF after pulmonary resection.