• 제목/요약/키워드: 전산화단층영상검사

검색결과 216건 처리시간 0.031초

A Deep Learning Model for Judging Presence or Absence of Lesions in the Chest X-ray Images (흉부 디지털 영상의 병변 유무 판단을 위한 딥러닝 모델)

  • Lee, Jong-Keun;Kim, Seon-Jin;Kwak, Nae-Joung;Kim, Dong-Woo;Ahn, Jae-Hyeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제24권2호
    • /
    • pp.212-218
    • /
    • 2020
  • There are dozens of different types of lesions that can be diagnosed through chest X-ray images, including Atelectasis, Cardiomegaly, Mass, Pneumothorax, and Effusion. Computed tomography(CT) test is generally necessary to determine the exact diagnosis and location and size of thoracic lesions, however computed tomography has disadvantages such as expensive cost and a lot of radiation exposure. Therefore, in this paper, we propose a deep learning algorithm for judging the presence or absence of lesions in chest X-ray images as the primary screening tool for the diagnosis of thoracic lesions. The proposed algorithm was designed by comparing various configuration methods to optimize the judgment of presence of lesions from chest X-ray. As a result, the evaluation rate of lesion presence of the proposed algorithm is about 1% better than the existing algorithm.

The convergence study on patient position and exposure dose in abdominal CT examination using AEC (AEC를 적용한 복부 CT 검사 시 환자 자세와 피폭선량에 대한 융합 연구)

  • Lee, Chun-Kyu;Oh, Jeong-Sub;Choi, Seon-Wook;Kim, Gab-Jung;Yoo, Se-Jong;Jeon, Min-Cheol
    • Journal of the Korea Convergence Society
    • /
    • 제9권12호
    • /
    • pp.107-113
    • /
    • 2018
  • The purpose of this study was to evaluate the dose and image quality according to the rotation of the X-axis direction in the abdominal CT scan, and to find ways to reduce the exposure dose. The phantom was scanned by rotating in the X-axis direction at 0, 5, 10, and 15 degrees, respectively. The CTDIvol value, HU, noise, and signal-to-noise ratio were measured at each rotation. ANOVA analysis was performed using the SPSSWIN (ver 19.0) program. The radiation exposure dose was 5.44mGy, 5.70mGy, 5.98mGy and 6.38mGy at 0, 5, 10 and 15 degrees, respectively. HU, noise, and signal-to-noise ratio were not statistically significant. In the CT scan, if the patient is located in the isocenter of the gantry aperture and there is no rotation in the X-axis direction, the exposure dose is reduced.

Delayed Contrast-enhanced Computed Tomography for Adrenal Masses in 3 Dogs (개 부신종양의 지연형 조영증강 전산화단층촬영 적용 3증례)

  • Lee, Jeo-soon;Yoon, Junghee;Oh, Hyun-jung;Kim, Bo-eun;Kim, Wan-hee;Youn, Hwa-young;Choi, Min-cheol
    • Journal of Veterinary Clinics
    • /
    • 제32권3호
    • /
    • pp.263-267
    • /
    • 2015
  • Three dogs having adrenal masses detected on ultrasonographic examination were underwent computed tomography (CT) for surgery. After adrenalectomy, each mass was diagnosed pheochromocytoma with myelolipoma, adrenocortical carcinoma and adrenal adenoma through histopathology. Five minutes were used to get delayed enhanced CT images. Attenuation value was measured in each mass and the absolute and relative percentage of enhancement washout were calculated.

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제11권11호
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.

Development of Tomographic Scan Method for Industrial Plants (산업공정반응기의 감마선 전산 단층촬영기술 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho;Kwon, Taek-Yong;Cho, Gyu-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제30권1호
    • /
    • pp.20-30
    • /
    • 2010
  • In this paper, a new tomographic scan method with fixed installed detectors and rotating source from gamma projector was presented to diagnose the industrial plants which were impossible to be examined by conventional tomographic systems. Weight matrix calculation method which was suitable for volumetric detector and statistical iterative reconstruction method were applied for reconstructing the simulation and experimental data. Monte Carlo simulations had been performed for two kinds of phantoms. Lab scale experiment with a same condition as one of phantoms, had been carried out. Simulation results showed that reconstruction from photopeak counting measurement gave the better results than from the gross counting measurement although photopeak counting measurement had large statistical errors. Experimental data showed the similar result as Monte Carlo simulation. Those results appeared to be promising for industrial tomographic applications, especially for petrochemical industries.

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • 제30권3호
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

Substitutability of Noise Reduction Algorithm based Conventional Thresholding Technique to U-Net Model for Pancreas Segmentation (이자 분할을 위한 노이즈 제거 알고리즘 기반 기존 임계값 기법 대비 U-Net 모델의 대체 가능성)

  • Sewon Lim;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • 제17권5호
    • /
    • pp.663-670
    • /
    • 2023
  • In this study, we aimed to perform a comparative evaluation using quantitative factors between a region-growing based segmentation with noise reduction algorithms and a U-Net based segmentation. Initially, we applied median filter, median modified Wiener filter, and fast non-local means algorithm to computed tomography (CT) images, followed by region-growing based segmentation. Additionally, we trained a U-Net based segmentation model to perform segmentation. Subsequently, to compare and evaluate the segmentation performance of cases with noise reduction algorithms and cases with U-Net, we measured root mean square error (RMSE) and peak signal to noise ratio (PSNR), universal quality image index (UQI), and dice similarity coefficient (DSC). The results showed that using U-Net for segmentation yielded the most improved performance. The values of RMSE, PSNR, UQI, and DSC were measured as 0.063, 72.11, 0.841, and 0.982 respectively, which indicated improvements of 1.97, 1.09, 5.30, and 1.99 times compared to noisy images. In conclusion, U-Net proved to be effective in enhancing segmentation performance compared to noise reduction algorithms in CT images.

CT and MRI Features of Localized Peritumoral Amyloidosis in a Patient with Head and Neck Mucosa-Associated Lymphoid Tissue Lymphoma: A Case Report (두경부 MALT 림프종 환자에서 나타난 국소적 종괴 주위 아밀로이증의 전산화단층촬영 및 자기공명영상 소견: 증례 보고)

  • Han Joon Kim;Hyun Sook Hong;Ji Yoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제82권5호
    • /
    • pp.1334-1340
    • /
    • 2021
  • Amyloidosis has been reported to be associated with non-Hodgkin lymphoma. Amyloidosis and lymphoma can be related in two ways: lymphoma-associated systemic amyloidosis and peritumoral amyloidosis with lymphoma. We report a rare case of peritumoral amyloidosis in a patient with head and neck mucosa-associated lymphoid tissue lymphoma. On CT, the oropharyngeal mass showed an irregularly shaped soft-tissue density with multifocal amorphous calcifications and heterogeneous enhancement. On MRI, the mass showed heterogeneous low signal intensity on both T1- and T2-weighted images. On contrast-enhanced MR images, the mass showed good enhancement with several inner non-enhancing foci. Concurrent pathologies, such as peritumoral amyloidosis, should be considered when calcifications are noted in patients with pre-treatment lymphoma.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • 제16권1호
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF

Successful Endovascular Treatment of an Infected Aortic Aneurysm Induced by Klebsiella pneumoniae (Klebsiella pneumonia로 인해 발생한 감염성 동맥류의 성공적인 혈관 내 치료)

  • Hong Gwon Byun;Yook Kim;Jung Hwan Lee;Jisun Lee;Kil Sun Park
    • Journal of the Korean Society of Radiology
    • /
    • 제81권3호
    • /
    • pp.733-738
    • /
    • 2020
  • Aortic aneurysms infected by Klebsiella pneumoniae are rarely seen. We describe a 50-year-old man with infected aortic aneurysm that was successfully treated with endovascular aneurysm repair (EVAR). Diagnosis was confirmed using blood culture and computed tomography (CT). Intravenous antibiotics were immediately administered, with improvements in clinical findings and negative blood cultures before the procedure. Twenty-four months after the procedure, the patient was stable and serial CT revealed regression of the infected aortic aneurysm. Therefore, after controlling bacteremia and fever with targeted antibiotic therapy, EVAR can be considered as an alternative for patients who have serious comorbidities and are ineligible for conventional surgery.