• Title/Summary/Keyword: 전산화단층영상검사

Search Result 216, Processing Time 0.029 seconds

A Case of Hepatopumonary Syndrome with Cyanosis (청색증으로 내원한 간폐증후군 1예)

  • Ryu, Dae-Sik;Jung, Bock-Hyun;Jung, Sang-Sik;Kim, Ho-Dong;Yoo, Chul-Hee;Kang, Kil-Hyeon;Kim, Nam-Hyeon;Jung, Seung-Mun;Park, Man-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.420-425
    • /
    • 1999
  • We report a case of hepatopulmonary syndrome defined as a triad of chronic liver disease, increased alveolar oxygen gradient on room air, and intrapulmonary arteriovenous shunting. Chest rediographs showed bilateral, basilar, medium sized reticulonodular opacities. High resolution CT scand showed multiple centrilobular nodules and branching structures in the subpleural lung that suggested dilatation of lung vessels with abnormally large number of visible terminal branches. $^{99m}Tc$-macroaggregated albumin(MAA) perfusion lung scan showed right to left shunt. Contrast echocardiography demonstrated intrapulmonary vascular shunt without intracardiac shunt.

  • PDF

Intracerebral Hemorrhage Auto Recognition in Computed Tomography Images (CT 영상에서 뇌출혈의 자동인식)

  • Choi, Seok-Yoon;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Ye, Soo-Young;Ko, Seong-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The CT examination sometimes fail to localize the cerebral hemorrhage part depending on the seriousness and may embarrass the pathologist if he/she is not trained enough for emergencies. Therefore, an assisting role is necessary for examination, automatic and quick detection of the cerebral hemorrhage part, and supply of the quantitative information in emergencies. the computer based automatic detection and recognition system may be of a great service to the bleeding part detection. As a result of this research, we succeeded not only in automatic detection of the cerebral hemorrhage part by grafting threshold value handling, morphological operation, and roundness calculation onto the bleeding part but also in development of the PCA based classifier to screen any wrong choice in the detection candidate group. We think if we apply the new developed system to the cerebral hemorrhage patient in his critical condition, it will be very valuable data to the medical team for operation planning.

A Case of Advanced Gastric Cancer with Deep Vein Thrombosis Treated with Low Molecular Weighted Heparin (전이성 위암환자의 심부정맥혈전증에 대한 저분자량 헤파린 투여 사례)

  • Su Jin Heo;Chan Hyuk Park;Sang Kil Lee
    • Journal of Digestive Cancer Research
    • /
    • v.1 no.2
    • /
    • pp.108-110
    • /
    • 2013
  • The relationship between malignancy and venous thromboembolism(VTE) has been well established. About 20% of all VTE cases are associated with cancer and thrombotic events are the second leading cause of death in cancer patients after death from cancer itself. Effective prophylaxis and treatment will reduce morbidity and may decrease overall mortality. We report a case of VTE in a patient with advanced gastric cancer who treated with low-molecular weighted heparin (LMWH). A 49-year-old man with heartburn was admitted to our hospital. On the endoscopic and radiologic imaging, the patient was diagnosed as an advanced gastric cancer with perigastric infiltration and liver metastasis. During the combination chemotherapy, he had pain and swelling of left lower leg. Doppler ultrasonography showed left posterior tibial venous thrombosis and pulmonary embolism CT showed thromboembolism in subsegmental pulmonary artery branch in right lower lobe. He was treated with LMWH, Dalteparin once daily via subcutaneous injection, and his symptoms was subsided.

  • PDF

A Method to Obtain the CT Attenuation Coefficient and Image Noise of Various Convolution Kernels in the Computed Tomography (Convolution Kernel의 종류에 따른 CT 감약계수 및 노이즈 측정에 관한 연구)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Our objective was to evaluate the CT attenuation coefficient and noise of spatial domain filtering as an alternative to additional image reconstruction using different kernels in abdominal CT. Derived from thin collimated source images was generated using abdomen B10 (very smooth), B20 (smooth), B30 (medium smooth), B40 (medium), B50 (medium sharp), B60 (sharp), B70 (very sharp) and B80 (ultra sharp) kernels. Quantitative CT coefficient and noise measurements provided comparable HU (hounsfield) units in this respect. CT attenuation coefficient (mean HU) values in the abdominal were 60.4$\sim$62.2 HU and noise (7.6$\sim$63.8 HU) in the liver parenchyma. In the stomach a mean (CT attenuation coefficient) of -2.2$\sim$0.8 HU and noise (10.1$\sim$82.4 HU) was measured. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. CT images increase the diagnostic accuracy may be controlled by adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination.

  • PDF

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

A Study on Misdiagnosis Rates of Ejection Fraction Associated with Cardiac Computed Tomography: Suggestions and Correction for Improvement (심장 전산화단층촬영을 이용한 박출계수 산출 시 박출계수의 보정을 통한 오진율 개선에 관한 연구)

  • Na, Sa-Ra;Jeong, Mi-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.437-444
    • /
    • 2021
  • The aim of this study was to compare the cardiac CT and cardiac MRI in calculating and correcting the left ventricle ejection fraction by analyzing the physical and temporal resolution for reducing the misdiagnosis rate. One hundred thirty-eight patients with aortic value regurgitation who underwent both cardiac CT and cardiac MRI were analyzed. Left ventricle ejection fractions calculated from each exam were corrected based on the physical and temporal resolution differences and the reliability test evaluated whether the misdiagnosis rate of cardiac CT was improved after the correction. As a result of the study, the misdiagnosis rate of cardiac CT ejection fraction before correcting the difference in physical and temporal resolution was 38.4%(53 persons). In addition, it can be seen that the corrected cardiac CT ejection fraction confirmed in the Bland-Altman plot was highly consistent with the ejection fraction of cardiac MRI. In conclusion, as the cardiac CT is less well suited for measuring ejection fraction, physical characteristics and the time resolution correction using cardiac MRI is needed and the misdiagnosis rate after correction decreased to 14.5%(20 persons). Therefore, this study appears more appropriate for better prediction of ejection fraction and clinical utility.

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination (Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구)

  • Lee, Ju Ryeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • The purpose of this study was to investigate whether there is a difference in image quality before and after reducing the amount of contrast medium in cerebral hemorrhagic patients who periodically follow up CT, and after reducing the amount of contrast medium, the image before and after reduction was examined, and the image quality was assessed by setting ROI at each vessel location using MMWP program. First Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA and Basilar Artery each got an ROI. Second, the mean and standard deviation values for the ROI were obtained. Third, SNR and CNR were obtained through the average and standard deviation values obtained. T-test statistics show that the SNR and CNR values obtained show that the result values for SNR are Rt.CCA 0.765, Ltd.CCA 0.871, Rt.MCA 0.343 LT.MCA 0.235, Basilar alternative 0.916, result value for CNR Rt.CCA 0.088, Ltd.CCA 0.069, Rt.MCA 0.818, Let's...MCA 0.579 and Basilar Artery 0.878. The results obtained through the obtained SNR and CNR values showed no difference in the quality of the images before and after reducing contrast medium. Therefore, we hope that this study will be an indicator that reduces the burden on contrast agents on patients who do CT examinations periodically.

Cystoperitoneal Shunting after Fenestration of an Enlarging Arachnoid Cyst

  • Jeon, Ik-Chan;Kim, Min-Su;Kim, Seong-Ho;Jang, Sung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.160-164
    • /
    • 2008
  • A two-month-old girl with a history of an incidental arachnoid cyst in the prenatal period (38 weeks) presented with persistent irritability. A follow-up computed tomographic (CT) scan revealed an enlarged arachnoid cyst with hydrocephalus. We performed craniotomy and fenestration, but the cyst size did not decrease, and hydrocephalus had worsened on a follow-up CT scan performed 13 months after fenestration. The patient was treated with cystoperitoneal shunting. Follow-up magnetic resonance imaging (MRI) performed 5 years later revealed that the arachnoid cyst had decreased in size and that the hydrocephalus had resolved. Enlarging arachnoid cysts are not common, and optimal surgical treatment is uncertain. Based on the features of this case, we believe cystoperitoneal shunting is an advisable surgical intervention for patients with enlarging arachnoid cysts presenting with hydrocephalus.

  • PDF

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.