• Title/Summary/Keyword: 전산화단층검사

Search Result 439, Processing Time 0.024 seconds

Comparative Study of 2 mm Video-thoracoscopic Examination and High-resolution Computed Tomography for Spontaneous Pneumothoarx Patients (자연기흉에서 고해상 전산화단층촬영술과 2 mm 비디오 흉강경검사의 비교 연구)

  • Lee, Song-Am;Chee, Hyun-Keun;Hwang, Jae-Joon;Cho, Seong-Joon;Lee, Sung-Ho;Kim, Kwang-Taik
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.362-368
    • /
    • 2007
  • Background: Spontaneous pneumothorax patients with blebs or bullae are considered to be good candidates for operation, and various objective diagnostic modalities have been performed for detection of blebs and bullae. This study was performed to compare the efficacy of thoracoscopic examination with using a minimally invasive 2 mm thoracoscope with high-resolution computed tomography (HRCT) for treating primary spontaneous pneumothorax. Material and Method: From June 2001 to March 2002, 34 patients with spontaneous pneumothorax undewent study with 2 mm video-thoracoscopic examination and HRCT. We regarded a blob larger than 5 mm in diameter as significant. Standard thoracoscopic wedge resection was performed in 18 patients with significant blob via a 2 mm video-thoracoscopic examination. 1 patient incurred bleeding, and the remaining 15 patients were treated with pleural drainage. Result: Multiple or single blob lesions were detected by 2 mm video-thoracoscope in 52.9% (18/34) of the patients with primary pneumothorax. For a total of 19 patients who were operated on, the diagnostic accuracy of the 2 mm video-thoracoscopic examination for bullae and blob was 94.7% (18/19), which was superior to that of HRCT (73.7%, 14/19). At a mean follow-up of $30{\pm}3$ months, no recurrence occurred in both the operative group and the non-operative group. Conclusion: 2 mm video-thoracoscopic examination under local anesthesia has higher diagnostic accuracy than HRCT, and it is a useful alternative for determining the operative indications for spontaneous pneumothorax.

Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography (전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교)

  • Kim, Yung-kyoon;Park, Sang-Hoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.253-259
    • /
    • 2017
  • The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection(keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting(MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed $35.8{\pm}12.2$ for rib, femur ($16.1{\pm}24.1$), pelvis($13.7{\pm}18.8$), and spine($179.0{\pm}61.8$). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom (AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.7
    • /
    • pp.114-123
    • /
    • 2007
  • The increasing use of computed tomography (CT) as a diagnostic tool creates the need from and efficient means of evaluating the performance of the CT scanner now in use. Accordingly, acceptance testing and quality assurance of CT is of great importance. The aim of this study is to analyze of AAPM CT performance phantom in the CT accreditation program. The modular phantom offers the CT system with which to measure eight performance parameters. The parameters are listed of CT attenuation coefficient of water, noise, uniformity, spatial resolution, contrast resolution, slice thickness (5 and 10 mm), artifacts and alignment. The phantom evaluation was done by two radiologists. The acceptance testing protocol described here in demonstrates the successful of the guidelines for the quality assurance using AAPM CT performance phantom. We need to be upgraded for the CT image quality and make the standard reference of the quality assurance in the CT.

Chest Computerized Tomographic Scan and Flexible Fiberoptic Bronchoscopy in the Diagnosis of Middle Lobe Syndrome (페중엽증후군에서 흉부 전산화 단층촬영 및 굴곡성 기관지경검사의 의의)

  • Lee, Nam-Ho;Lee, Hong-Leyol;Kim, Se-Kye;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.236-241
    • /
    • 1992
  • Background: As well as fiberoptic bronchoscopy, chest computerized tomographic scan can now differentiate the benign from malignant causes and the obstructive from non-obstructive causes of lung collapse. This study was designed to evaluate the usefulness of chest CT scan and fiberoptic bronchoscopy in the diagnosis of middle lobe syndrome. Method: We reviewed the clinical features, roentgenographic changes, pathologic findings and bronchoscopic findings in 16 patients with middle lobe syndrome who were admitted to Severance Hospital during period of January, 1987 through January, 1992. Results: The male to female ratio was 1:1. The most common symptoms were cough and sputums. Crackle was the most common physical finding. Underlying disease was lung cancer, pulmonary tuberculosis and endobronchial tuberculosis in 3 each other, benign stenosis in 2, lung abscess, broncholithiasis, bronchial chondroma, pneumonia and nonspecific inflammation in 1 each other. Conclusion: We conclude that the combination of chest computerized tomogram and fiberoptic bronchoscopy was most desirable for the diagnosis of middle lobe syndrome.

  • PDF

Examinations and Diagnoses for Hip Diseases Require Arthroscopic Management (관절경적 접근이 필요한 고관절 질환의 검진과 진단)

  • Rhyu, Kee-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.71-78
    • /
    • 2010
  • 관절경적인 접근이 필요한 고관절의 동통을 호소하는 젊은 환자의 감별에서 가장 중요한 것은 동통의 원인이 관절 내인지, 관절외인지를 확인하는 것이다. 이에는 다양한 임상 진찰이 사용되지만, 이 뿐 아니라 단순 방사선 검사, 전산화 단층촬영, 자기공명영상, 초음파, 관절조영술 등의 다양한 조합을 통한 관찰이 중요하다. 그러나 진찰이나 병력 등을 통해 어느정도 의심되는 질환을 생각하지 않고 검사를 진행한다면 아무 결과를 얻을 수 없거나, 검사를 하고서도 병변을 찾아내지 못하는 문제가 발생할 수 있다. 이를 피하기 위해 검사의 선택시 각 검사 방법의 특징과 의심되는 질환의 성격을 잘 이해하는 것이 무엇보다 중요하다.

  • PDF

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance (전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상)

  • Kweon Dae Cheol;Kim Tae Hyung;Yang Sung Hwan;Yoo Beong Gyu;Kim Myeong Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • We report a case of an accidental extravasation of contrast material. A large-volume extravasation occurred in an adult during spiral contrast-enhanced CT. The amount of contrast material extravasated was 47 ml. The patient had a swelling of the dorsum right hand. The extravasation injury site was determined by CT scanning. The extavasation case was examined using five separate display techniques: axial, multi planar reformation (MPR), maximum intensity projection (MIP), volume rendering, and shaded-surfaced display (SSD). This paper introduces extravasation with the CT and the three-dimensional appearance.

  • PDF

슬개 대퇴 불안정성에 대한 진단적 접근 방법

  • Kyung, H.S.;Hwang, J.K.
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.84-94
    • /
    • 2008
  • 슬개 대퇴 불안정성의 진단은 정확한 해부학적 지식을 바탕으로 역동적인(dynamic)기전을 이해하여야 한다. 슬개골의 저명한 탈구는 쉽게 진단되지만, 경미한 외상으로 슬개골이 탈구되어 정복된 후에는 올바른 진찰(dynamic study)없이 방사선 검사(static study)만으로는 진단을 놓치는 경우가 많다. 그러므로 정확한 진단을 위해서는 병력, 이학적 검사, 방사선 검사, 전산화 단층 촬영, 자기 공명 영상 그리고 관절경 검사까지 다양하게 필요할 수 있다.

  • PDF

Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units (건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.229-235
    • /
    • 2017
  • In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60~90% of sensitivity and 84~95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

Computed tomographic evaluation of experimental hydronephrosis treated with transarterial embolization of renal artery in Beagle dogs (신장동맥 색전술을 실시한 실험적 수신증의 전산화 단층촬영)

  • Chang, Dongwoo;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.421-427
    • /
    • 2001
  • This study was performed to evaluate the embolized kidney and contralateral normal kidney using computed tomography (CT) and enhanced computed tomography. Experimental hydronephrosis was induced by ligation of unilateral ureter in Beagle dogs. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$, body temperature, pulse, and repiratory rate were within normal ranges during procedures. Iohexol-ethanol solution was used as embolic material. There were no dogs expired after TAE-Ra and no side effects associated with regurgitation of iohexol-ehtanol solution. Revascularization of renal artery was not found in angiography in dogs treated by TAE-RA at immediately after TAE-RA and 14 days after TAE-RA. CT showed dilation of urinary collection system and ventral displacement of spleen at 14 days after TAE-RA in one dog not treated by TAE-RA and experimental group treated by TAE-Ra. CT two month after TAE-RA showed the shrunken embolized kidney in experimental group. Transverse CT with contrast enhancement demonstrated the increase of signal intensity at thinned renal cortex in control group not treated by TAE-Ra at 30 days and 60 days, however, there was no increase of signal intensity at shrunken embolized kidney at 60 days after TAE-RA. CT was useful modality for evaluation of the morphology and the size of embolized kidney and contralateral normal kidney. Enhanced CT was availabel for the detection of revascularization of renal artery after TAE-RA in dogs with hydronephrosis. It is conclued that CT is useful modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF