• Title/Summary/Keyword: 전방운동

Search Result 314, Processing Time 0.034 seconds

The Clinical Experiences of Patch Angioplasty in Isolated Critical Left Main Coronary Artery Stenosis (첨포를 이용한 좌주관상동맥 협착증의 치료)

  • 윤치순;유경종;이교준;김대준;강면식
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.674-678
    • /
    • 1998
  • The conventional surgical treatment of isolated critical stenosis of the left main coronary artery restores a less physiologic perfusion of the myocardium, leads to occlusion of the left coronary ostium, and consumes an appreciable length of bypass material. From June 1994 to February 1996, eleven patients, three male and eight female, underwent patch angioplasty and additional bypass graft to left anterior descending artery (10 internal mammary artery, 1 saphenous vein) in isolated critical left main coronary artery stenosis. Their ages ranged from 34 to 62 years, mean 44 years. All had 60% to 90% stenosis of the left main coronary artery and Class III angina. The angiogram showed nine osteal lesion and three main stem stenosis. The operation was performed with conventional cardiopulmonary bypass and cold blood cardioplegia. We approached anteriorly and used bovine pericardium as onlay patch in all patients. There were one leg wound dehiscence, but no operative deaths and infarctions. All patients are free of symptoms after a mean follow-up of 15.5 months. Angiographic restudy at an average 14.4 months was obtained in five patients and showed widely patent left main coronary artery with excellent runoff. But additional graft to left anterior descending coronary artery were stenosed in two patients and showed diminutive flow in others. Our preliminary results suggest that angioplasty of the left main coronary artery can be carried out with low operative risks. But additional bypass graft to left anterior descending coronary artery may be unnecessary. The technique appears to be a promising alternative to conventional coronary artery bypass grafting in isolated left main coronary artery stenosis.

  • PDF

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

Arthroscopic Treatment for the Pigmented Villonodular Synovitis in the Knee (슬관절에 발생한 색소 융모 결절성 활액막염의 관절경적 치료)

  • Bae, Dae-Kyung;Cho, Nam-Su
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.22-26
    • /
    • 2001
  • Purpose : To confirm the efficacy of arthroscopic synovectomy fur the pigmented villonodular synovitis in the knee. Materials and Methods : Between October 1996 and February 2000, the arthroscopic synovectomy had been performed in six patients(six knee joints), whose diagnoses were confirmed by pathologist. All patients complained of painful swelling in involved knee and four of the six patients had trauma history. There were three male and three female patients. Average age was 35.8 years ranging from 16 to 67 years. Follow up period was average 22.7 months(range, $13\~53$ months). Results : According to arthroscopic findings, there were three localized forms and three diffuse forms. At their last follow-up examinations, all patients had improvement in pain, swelling and range of motion and there was no evidence of recurrence. Conclusion : Complete arthroscopic excision is the definitive treatment for localized pigmented villonodular synovitis and meticulous arthroscopic excision through all portals including posterior portal can be considered as a valid alternative to traditional open synovectomy for the patients with diffuse pigmented villonodular synovitis.

  • PDF

Correlation of Clinical Outcome and Cuff Integrity after Open Repair in Large and Massive Rotator Cuff Tears (대형 및 광범위 회전근 개 파열의 개방적 봉합술 후 임상적 결과와 회전근 개 연속성(integrity)의 상관 관계)

  • Noh, Haeng-Kee;Wang, Joon-Ho;Kim, Dong-Hwee;Park, Jong-Woong;Kim, Jae-Gyoon;Park, Jung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • Purpose: To evaluate the relationship between the clinical outcome and the cuff integrity following open repair in large and massive rotator cuff tears using ultrasonography as an imaging modality. Material and Methods: From November 2001 to April 2005, 17 cases(16 patients) who had open repair of tear measuring more than 3cm were assessed with minimal follow-up of 12 months in this study. 6 cases had a large tear and 11 cases a massive tear. There were 6 men and 11 women with a mean age of 52 years at surgery (range, 33 to 72 years). The evaluation consisted of the preoperative and postoperative shoulder scores according to UCLA shoulder scoring system and Visual analogue scale (VAS). Ultrasonography was performed by a experienced musculoskeletal physician at a minimum of 12 months postoperatively to evaluate the postoperative cuff integrity. Results: Retear were detected in four of seventeen cases. Regardless of the presence of recurrent tear, 14 cases had UCLA score of more than 29 points (good grade). All 17 had an improvement in the functional score, which increased from an average of 15.1 to 31.2 points. All cases showed pain relief and five cases had no pain. Sixteen cases except one had the range of motion of forward elevation above $90^{\circ}$. Conclusion: Open rotator cuff repair in large and massive tears showed low retear rate. At a minimum of twelve months follow-up, all cases had improvement on UCLA score, pain relief, increased range of motion of the shoulder regardless of retear. And the correlation between recurrent tear and function score was not statistically significant.

Arthroscopic Treatment of Meniscal Cyst (슬관절 반월상 연골 낭종의 관절경적 치료)

  • Bae, Dae-Kyung;Yoon, Kyung-Ho;Kwon, Oh-Soo;Shin, Dong-Jun;Im, Yang-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.14-20
    • /
    • 2002
  • Purpose : To analyze the clinical result of the arthroscopic decompression of meniscal cyst and meniscus resection or repair of meniscus tear. Materials and Methods : From April 1994 and October 2001, 19 patients with diagnosis of meniscal cyst associated with tears of the meniscus were treated by arthroscopic meniscal resection or repair with decompression of the cyst. The mean age was 39.8 years(range, 22-58years). The follow-up period ranged from 3 months to 36 months with an average of 18 months. Seven of 19 patients had tenderness over the joint line with palpable mass. Treatment consists of arthroscopic resection or repair of meniscal tear with decompression of the cyst through transmeniscal approach. Open excision of cyst was performed in one case. Clinical evaluation was performed using Lysholm knee score and Tegner activity. All cases were executed proper treatment using arthroscopy. Results : Twelve cysts involved the lateral meniscus$(64\%)$ and seven cysts were on medial cyst$(36\%)$. Most of lateral meniscal cysts were located in anterior one-third and medial meniscal cyst were on posterior one-third. Meniscal tear were observed in seventeen cases$(89.5\%)$ and most tears were horizontal$(79\%)$. Preoperative symptom disappeared and no cyst recurrences were observed at last follow-up(mean follow-up: 18 months). Conclusion : Meniscal cysts involved lateral side in $64\%$ and most of them were associated with meniscus tear$(89.5\%)$ which consists of mainly horizontal component$(79\%)$.

  • PDF

The Use of Arthroscopic UU Stich for Rotator Cuff Tear and Clinical Results (회전근 개 파열의 관절경하 봉합에서 새로운 봉합 방법의 이용)

  • Ko, Sang-Hun;Shin, Seung-Myeong;Choi, Young-Jin;Cha, Jae-Ryong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: There are various known methods for arthroscopic rotator cuff repair. The purpose of this retrospective study is to report on the clinical results and anatomical results of UU repair surgery, which is a new repair method. Materials and Methods: We enrolled 156 patients (88 men and 68 women) who underwent UU repair for rotator cuff tears from January 2009 to May 2010 in our hospital. Their average age was 55 years old (range: 38~75 years old) and the average follow-up period was 12 months (range: 6~23 months). For determining the results, we evaluated the VAS for pain, the daily living index (ADL) in the ASES scores, the UCLA and KSS scores, and all these tests were conducted at the first hospital visit and 6 months and 1 year after surgery and at the final follow-up. During the follow-up period, MRI was performed 3 and 6 months after surgery only in the patients who consented to MRI scans to confirm the presence of re-rupture. Results: The average scores of the VAS as a pain indicator decreased from 7.0 before surgery to 2.7 after surgery (p<0.05). The UCLA and KSS scores increased from 22.2 to 32.5 and from 83.7 to 91.5, and the changes was significant (p<0.05). For the active joint range of motion, the average forward flexion was improved from 125 to 175 degrees, the average lateral external rotation was improved from 38 to 58 degrees, and the average abduction was improved from 104 to 169 degrees. Out of a total of 156 patients, re-rupture was observed in 4 cases (3%) of 117 cases (75%) for which MRI was performed (with consent) between 3 and 6 months after surgery. Conclusion: UU repair surgery as arthroscopic repair of rotator cuff tear is a good repair method that shows excellent clinical results and a low re-rupture rate.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF