• Title/Summary/Keyword: 전류 변압기

Search Result 474, Processing Time 0.03 seconds

A Current Differential Relaying Algorithm for Power Transformers Using the Difference of a Differential Current (차전류의 차분을 이용한 변압기 보호용 전류차동 계전방식)

  • Kang, Y.C.;Kim, D.S.;Lee, B.E.;Kim, E.S.;Won, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.274-276
    • /
    • 2002
  • This paper proposes a current differential relaying algorithm for power transformers using the third difference function of a differential current. The algorithm observes the instants when the wave-shape of the differential current is changed due to the change of the magnetization inductance. If the value of the third difference is bigger than the threshold, the output of a current differential relay is blocked for a cycle. In the cases of magnetic inrush and overexcitation, the blocking signal is maintained: however, for internal faults, reset in a cycle. The test results clearly show that the algorithm successfully distinguishes internal faults from magnetizing inrush.

  • PDF

A High Efficiency Three-Phase ZVZCS DC-DC Converter for Fuel Cell Applications (연료전지 응용을 위한 고효율 3상 ZVZCS DC-DC 컨버터)

  • Kim, Hyung-Joon;Yoon, Chang-Woo;Choi, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.213-215
    • /
    • 2008
  • 본 논문에서는 수 kW급 이상의 연료전지 응용을 위한 고효율 전압원 3상 DC-DC 컨버터를 제안한다. 제안한 컨버터는 전압원 컨버터임에도 작은 턴비(기존 풀브리지의 1/2 이하)를 가지며 입 출력 전류 리플이 작다. 또한 클램프 회로의 동작으로 다이오드 서지전압 제거는 물론 저전압측 순환전류를 큰 폭으로 감소시켜 스위치의 도통손실과 변압기의 동손을 최소화하였고 전 부하영역에서 하측 스위치의 ZVZCS를 성취하여 스위칭 손실을 최소화 하였다. 또한 유효 듀티를 증가시켜 누설인덕턴스에 의한 듀티 손실을 보상하였다. 본 논문에서는 제안하는 컨버터의 동작원리를 서술하고 1.5kW Prototype을 제작하여 실험을 통해 본 방식의 타당성을 검증하였다.

  • PDF

A Current Differential Relaying Algorithm for Power Transformers Using an Advanced Compensation Algorithm of CTs (잔류자속에 무관한 전류보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식)

  • Kang, Y.C.;Lim, U.J.;Yun, J.S.;Jin, E.S.;Won, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.314-316
    • /
    • 2003
  • To prevent maloperation during magnetic inrush and over-excitation, a current differential relay for power transformers uses harmonic current based restraining or blocking scheme; it also uses dual slope characteristics to prevent maloperation for an external fault with CT saturation. This paper proposes a current differential relaying algorithm for power transformers with an advanced compensation algorithm for the secondary current of CTs. The comparative study was conducted with and without the compensating algorithm. The algorithm can reduce the operating time of the relay in the case of an internal fault and improve security for external faults.

  • PDF

${SF_6}Gas$의 절연파괴 및 전류펄스

  • 이동인
    • 전기의세계
    • /
    • v.27 no.3
    • /
    • pp.3-6
    • /
    • 1978
  • SF$_{6}$gas는 고정압 게통의 모든 분야에 광범위하게 사용되여 차단기의 소호재료로써 또는 초초고압용의 cable 및 변압기등의 절연재료로써 많이 사용되어지고 있다. 이러한 모든 분야에서 보여주는 SF$_{6}$gas의 우수한 절연특성은 이 Gas의 사용범위를 더욱 확대시켜 줄 것이라고 생각된다. 그러나 이러한 높은 절연강도도 고기압하에서는 기대되어지는 절연강도 보다 훨씬 낮아지는 경향이 있으며 이러한 경향은 사용압력이 높아질수록 현저하다. 그러나 고전압용 전기기기의 절연재료로써 고기압의 SF$_{6}$gas가 점차적으로 많이 사용되고 있기 때문에 이 고기압 SF$_{6}$에 관한 연구 결과중 우선 여기서는 평등전계에서 전극표면상태 및 면적등에 의한 영향과 절연파괴 직전의 전류펄스에 대한 것을 저기압 SF$_{6}$gas에 관한 결과와 함께 기술하고자 한다.

  • PDF

A Current Differential Relay for Transformer Protection with a Blocking Method Using the Difference-Function of a Differential Current (차전류 차분 블로킹 변압기 보호용 전류차동 계전기)

  • 강용철;원성호;김대성;양성채
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.691-697
    • /
    • 2003
  • This paper proposes a current differential relay for transformer protection that operates in accordance with a blocking method based on the difference-function of a differential current. For magnetic inrush and over-excitation, discontinuities in the first-difference function of the differential current arise at the points of inflection, which correspond to the start and end of each saturation period of the core. These discontinuities are converted into the pulses in the second- and third-difference functions of the differential current. The magnitudes of the pulses are large enough to detect saturation of the core. A blocking signal is issued if the magnitude of the third-difference function exceeds the threshold and is maintained for three quarters of a cycle. The performance of the relay is assessed under various conditions with magnetic inrush, internal faults and external faults. The proposed blocking method can improve significantly the operating time of a relay and achieve high sensitivity of a relay.

A Development of COS Holder to Reduce an Impact Ambient Noise (충격성 소음 감소용 COS 홀더 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1062-1068
    • /
    • 2007
  • We are using COS to block the excess current and to protect the transformer. But the fuse of COS is melt due to the overload resulting from the excess current flows and it destroys an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, it is necessary that we urgently need to control the ambient noise from the actual circumstances. In this study, we investigate the characteristic of an impact ambient noise associate with the melting state of the COS fuse and suggest the method to reduce the noise.

  • PDF

Operational Characterization of the Dual Active Bridge Converter under Phase-Duty Control (위상-듀티 제어된 듀얼 액티브 브릿지 컨버터의 운용 특성 연구)

  • Choi, Wooin;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.307-308
    • /
    • 2014
  • 듀얼 액티브 브릿지 컨버터는 고전력 전달에 유용한 절연형 양방향 컨버터이다. 듀얼 액티브 브릿지 (DAB) 컨버터의 가장 간단한 제어 방식은 고주파 변압기의 일차단과 이차단의 위상 차이를 통해 전달 전력을 제어하는 위상천이변조 (PSM) 방식이다. 그러나 위상 변동 방식을 이용하면 경부하 상황에서 소프트 스위칭이 이루어지지 않으며 순환 전류 또한 크게 발생하여 변환 효율이 낮아지게 된다. 본 논문에서는 위상 및 듀티가 변동된 컨버터의 최적 동작점을 파악하기 위한 DAB 컨버터의 운용 특성 연구를 수행하였다. 컨버터의 위상과 듀티에 따른 동작 파형, 경계 조건, RMS 전류, 소프트스위칭의 여부 등이 분석되었다.

  • PDF

Suppression of Current Harmonics with Triple Delta Sourced Winding and Novel Connection of Common-mode Filter (4권선 변압기의 삼중 델타 전원 연결과 새로운 커먼-모드 필터 연결방법을 이용한 전류 고조파 저감)

  • Ohn, Sungjae;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.245-246
    • /
    • 2015
  • 본 논문에서는 삼중 델타 전원과 새로운 커먼-모드 필터 결선을 통해 스위칭에 의한 고조파를 저감하는 방법을 제안한다. PWM에 의해 생성되는 측대파 고조파(Sideband harmonics) 위상을 분석함으로써, 인터리빙 운전 시 삼중 델타 전원 연결과 제안된 커먼모드 필터가 측대파 고조파 전류를 크게 저감할 수 있음을 보인다. 3개의 고정자 권선을 가지는 영구자석 전동기를 이용하여 제안된 필터의 유효성을 검증하였다.

  • PDF

Optimal Design Methodology of a 500 W Wireless Power Transfer Converter (500 W급 무선 전력 전송용 컨버터의 최적설계 방법에 관한 연구)

  • Kim, Mina;Kim, Katherine A.;Jung, Jeehoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.19-20
    • /
    • 2015
  • 본 논문은 동작 주파수에 따른 임피던스 분석을 통해 무선 전력 전송 컨버터의 최적 설계 방법을 제안한다. 기존의 무선 전력 전송에는 크게 4가지의 토폴로지가 있는데 본 논문은 SS 토폴로지에 대한 최적 설계 방법을 제시한다. 무선 전력 전송이 가지는 근본적인 특징인 코일 간의 낮은 커플링 계수로 인해 컨버터 설계 시 많은 제약 사항들을 고려해야 한다. 일반적인 변압기와 달리 코일 간의 커플링 계수가 0.2 안팎이므로 충분한 자화 인덕턴스를 가지기 위해서는 코일의 턴 수를 늘리는 방안이 있으나 턴 수에 따라 코일 저항이 늘어나, 도통 손실이 증가하는 문제가 있다. 또한 낮은 자화 인덕턴스는 높은 자화전류에 의한 컨버터의 1차 측 전류의 상승을 야기하며, 도통손실을 증가시킨다. 따라서 본 논문에서는 무선 전력 전송용 컨버터의 최적 설계를 임피던스 변화의 관점에서 수학적인 분석을 통해 제안하고, 그에 따른 시뮬레이션으로 검증하고자 한다.

  • PDF

A New Soft-switched Converter with Low-voltage Rated Switch and wide voltage range for 800V/14V LDC (낮은 스위치 전압정격과 넓은 전압범위를 갖는 800V/14V LDC용 새로운 소프트 스위칭 컨버터)

  • Kim, Byeongwoo;Kim, Kangsan;Kim, Kyuyeong;Lee, Donghan;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.56-58
    • /
    • 2018
  • 본 논문에서는 낮은 스위치 전압정격과 넓은 전압범위를 갖는 800V/14V LDC용 새로운 소프트 스위칭 컨버터를 제안한다. 제안하는 컨버터는 입력이 직렬구조로써 입력전압의 절반으로 낮은 스위치의 전압정격을 갖기 때문에 600V의 Si-MOSFET를 사용할 수 있어 도통손실을 줄일 수 있으며 넓은 입력전압 및 부하영역에서 소프트 스위칭을 성취하여 높은 효율을 달성할 수 있고 변압기의 직렬연결로 된 커패시터로 인해 자화전류의 오프셋이 없다. 또한 2차 측의 DC 블로킹 커패시터에 인터리빙 방식을 적용하여 기존의 전류정격이 큰 문제를 해결하였다. 제안하는 소프트 스위칭 컨버터의 동작원리를 제시하고 시작품을 통해 본 논문의 타당성을 검증하였다.

  • PDF