A Study of Current Perception Threshold of Trigeminal Nerve after Tooth Implantation (치아임플란트 시술 후 삼차신경에서의 전류인지역치에 대한 연구)

  • Lim, Hyun-Dae;Lee, Jung-Hyun;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.187-200
    • /
    • 2007
  • This study attempted to contribute to the clinical application of implant operation by making a quantitative nerve examination using a neurometer for the evaluation of sensory disturbances that could be incurred after the implantation in the dental clinics, and it intended to establish an objective guideline in the evaluation of sensory nerve after the operation of implant. An inspection was performed with the frequencies of 2000Hz, 250 Hz and 5 Hz before and after the operations of tooth implant using $Neurometer^{(R)}$ CPT/C (Neurotron, Inc. Baltimore, Maryland, USA) for 44 patients who had performed an implant operation among the patients coming to Daejeon Sun Dental Hospital in 2006 and 30 people for control group. The measuring sites were maxillary nerve ending and mandibular nerve ending of trigeminal nerve according to the implant operating regions. The current perception threshold (CPT) by each nerve fiber was specifically responded under the electric stimulation of 2000 Hz in case of $A{\beta}$ fiber and of 250 Hz in case of $A{\delta}$ fiber and of 5Hz in case of C fiber. The CPT test could be performed to assess the damages of peripheral nerve in the trigeminal nerve area and it stimulated selective nerve fibers by generating the electricity of specific frequency in the peripheral nerve area. The nerve fibers with varied thickness were responsive selectively to the electric stimulation with different frequencies; accordingly, they applied the electric stimulation with different frequencies and the reaction threshold of $A{\beta},\;A{\delta}$ and C fibers selectively responsive to each electric current could be individually evaluated. In the assessment through the CPT, the increase and decrease of the CPT could be measured so that sensory disturbances such as hyperaesthesia or hypoaesthesia could be diagnosed. This study could obtain the following results after the assessment of the CPT before and after the implant operation. 1. In the assessment before and after the implant operation, the CPT in the frequencies of 2000 Hz, 250 Hz, 5 Hz for maxillary branch increased on the whole after the operation and the CPT for mandibular branch in the $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz )after the operation increased statistically significantly. 2. For the groups of patients with medically compromised or its subsequent medicinal prescription, there were no significant differences before and after the implant operation and for the control groups, significantly high CPT was shown after the implant operation in the left $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz). 3. In the comparison of the measured value of the CPT before the operation between the control group and the implant operation group, the latter group had a significantly high measured value of the CPT in the right $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz) and there were significant differences in $A{\beta}$-fiber(2000 Hz) in the CPT assessment after the implant operation for the control group. 4. Male participants had higher CPT than female counterparts; however, there were no statistic significances. In the CPT evaluation before and after implant operation, there were no statistical differences in the male group while the right C-fiber(5 Hz) and left $A{\beta}$-fiber(2000Hz) were significantly high in the female group. 5. In the comparison between the group who complain sensory disturbance and the other group, the CPT increased on the whole in the former group, but there were no statistical significances. In the groups, whom there was an increase in VAS, the CPT after the implant operation in the right C-fiber(5 Hz) increased significantly; meanwhile, in case that the VAS mark was '0' before and after the operation, the CPT after the operation in the left $A{\beta}$-fiber(2000 Hz) increased significantly. This study suggested that the CPT measurements using $Neurometer^{(R)}$ CPT/C, provide useful information of objective and quantitative sensory disturbances for tooth implantation.

Analysis of Current Perception Threshold(CPT) Change after Dental Surgery using Neurometer (치과 수술 후 뉴로미터를 이용한 전류인지역치의 변화의 분석)

  • Park, Jin-Hyung;Ryu, Ji-Won;Ahn, Jong-Mo;Ok, Soo-Min;Yoon, Chang-Lyuk
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2010
  • The goal of this study is to contribute to the clinical application by making a quantitative nerve current perception threshold(CPT) examination for the evaluation of numbness that could be occurred after dental surgery, Measurement of CPTs at each different frequencies(2000 Hz, 250 Hz, and 5 Hz) were performed to trigeminal nerve main branch(mandibular division) of 29 patients with dental surgery on mandibular area and 25 normal subjects. There were significant differences in CPTs between patient group and control group.(p<0.05) But, there were no significant between patient male and female in both patient and control group except 2000 Hz was significantly high in the control female.

The Effects of Low Level Laser Therapy on Current Perception in Trigeminal Neuralgia Patients (삼차신경통 환자에서 저출력레이저 조사에 따른 전류인지역치의 변화효과)

  • Heo, Jun-Young;Tae, Il-Ho;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.1
    • /
    • pp.97-103
    • /
    • 2008
  • The purpose of this study was to examine the effect of LLLT on current perception threshold in trigeminal neuralgia patients. Affected site and non-affected site was irradiated by GaAlAs diode laser. Current perception threshold was evaluated with $Neurometer^{(R)}$ CPT/C before and after LLLT. As an outcomes,CPT were obtained. We made a comparision of these values and the results were as follows. 1. There were no significant difference in CPT between affected site and non-affected site before and after LLLT irradiation. 2. There were no significant difference in CPT between affected site and non-affected site after LLLT irradiation. 3. But, CPT values of $A{\beta}$ fiber incresed slightly on both site after LLLT irradiation

Case Report : Non-surgical Treatment of Inferior Alveolar Nerve Injury as a Result of Overinstrumented Root Canal Treatment (근관 충전제의 과충전에 의한 하치조 신경손상에 관한 비수술적 치료 증례)

  • Bae, Kook-Jin;Ahn, Jong-Mo;Yoon, Chang-Lyuk;Cho, Young-Gon;Ryu, Ji-Won
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • During root canal treatment, overinstrumentation with hand or mechanically driven files can perforate the mandibular canal, allowing the extrusion of endodontic sealers, dressing agents, and irrigant solutions out of the tooth and into the canal. The patient may report symptoms such as pain, hyperesthesia, hypoesthesia, anesthesia, dysesthesia and paresthesia. Such problems must be resolved as quickly as possible to avoid irreversible sequelae caused by certain neurotoxic materials that form part of endodontic sealants. Although there have been no controlled trials of treatment protocols involving endodontically related injuries to the inferior alveolar nerve, the normal therapeutic sequence for this complication is the control of pain and inflammation and, whenever possible, the surgical elimination of the cause. However, total resolution of pain and reduction in or disappearance of paraesthesia after a non-surgical management have been reported. Antiepileptic drugs such as gabapentin or pregabalin have been used for the treatment of neuropathic pain. This article describes a case of inferior alveolar nerve(IAN) damage after endodontic treatment of a mandibular right second molar and the treatment with non-surgical approach using prednisone and gabapentin medication, monitoring the patient's condition with clinical neurosensory examination and current perception threshold test(Neurometer).

Reliability of Quantitative Sensory Testing Using Current Perception Thresholds in the Mandibular Nerve Area (하악신경영역에서 전류인지역치를 이용한 정량적 감각신경 검사의 재현성 조사)

  • Choi, Hee-Hun;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.2
    • /
    • pp.131-137
    • /
    • 2011
  • Current Perception Threshold (CPT) using Neurometer($Neurometer^{(R)}$ CPT/C) is thought as one of easy and noninvasive QST(qunatitative sensory testing) tools for A${\beta}$, A${\delta}$ and C fibers within a relatively short time. However, conflicts about its reliability still exist. This study aimed to evaluate the reliability of CPTs evaluation and find a way to increase its reliability. Two examiners separately tested CPTs at each side of the mandibluar nerve areas for ten healthy male adults (average age of 22.4 years) three times with an intervals of a week during three weeks. Mean CPTs were compared between the right and left sides of the mandibular nerve area and between the three examinations on the each side. While CPTs at 2000 Hz(A${\beta}$ fiber) showed statistically significant side differences in all three examinations (p<0.05), significant side difference was found in only one examination at 250 Hz(A${\delta}$ fiber) and no difference at 5 Hz(C fiber). Comparing CPTs on the each side of the mandibular nerve area, all examinations at all sensory nerve fibers showed the least CPTs at the 1st examinations. CPTs at 250 Hz(A${\delta}$ fiber) and 5 Hz(C fiber) were significantly different between the first and the following examinations (p<0.05) and there was no significant difference between 2nd and 3rd examinations. The results of this study indicated that CPTs at 250 Hz(A${\delta}$ fiber) and 5 Hz(C fiber) are reliable but CPTs at 2000 Hz(A${\beta}$ fiber) is not appropriate for evaluation of side differences in the mandibular nerve area. In addition, it is suggested that repeated examination be helpful to increase reliability of the CPT evaluation.