• Title/Summary/Keyword: 전류데이터

Search Result 497, Processing Time 0.026 seconds

Design of Readout Circuit with Dual Slope Correction for photo sensor of LTPS TFT-LCD (LTPS TFT LCD 패널의 광 센서를 위한 dual slope 보정 회로)

  • Woo, Doo-Hyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.31-38
    • /
    • 2009
  • To improve the image quality and lower the power consumption of the mobile applications, it is the one of the best candidate to control the backlight unit of the LCD module with ambient light. Ambient light sensor and readout circuit were integrated in LCD panel for the mobile applications, and we designed them with LTPS TFT. We proposed noble start-up correction in order to correct the variation of the photo sensors in each panel. We used time-to-digital method for converting photo current to digital data. To effectively merge time-to-digital method with start-up correction, we proposed noble dual slope correction method. The entire readout circuit was designed and estimated with LTPS TFT process. The readout circuit has very simple and stable structure and timing, so it is suitable for LTPS TFT process. The readout circuit can correct the variation of the photo sensors without an additional equipment, and it outputs the 4-levels digital data per decade for input luminance that has a dynamic range of 60dB. The readout rate is 100 times/sec, and the linearity error for digital conversion is less than 18%.

PAPR Reduction Technique and BER Performance Improvement in OFDM-based Wireless Visible Light Communication (OFDM을 사용하는 무선 가시 광통신에서의 PAPR 저감 기법과 BER성능 개선)

  • Ryu, Sang-Burm;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3A
    • /
    • pp.189-197
    • /
    • 2011
  • OFDM systems are much studied for the recent high speed wireless optical communication system. OFDM system has basically high PAPR and ICI easily generated because of non-linearity and RF impairments. In the wireless optical communication system, optical output power driven by current of LED is not linear so that transmission signals are distorted. Therefore, research about reception performance of this nonlinear optical output emitted by non-linear LED transfer function and OFDM signal has been conducted. Nonlinear effect of LED is different from nonlinear effect of OFDM system in the conventional radio communication system, which degrades the BER performance. In this paper, we apply non-linear transfer function of recently studied LED into OFDM system. So, for reducing the PAPR and suppressing the ICI in frequency domain of receiver, we suggest a new PAPR reduction technique to reduce non-linear distortion of LED and an adaptive ICI suppression algorithm so that BER performance may be improved. Also, the proposed method is verified through simulation results.

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF

Sensorless Speed Control of Direct Current Motor by Neural Network (신경회로망을 이용한 직류전동기의 센서리스 속도제어)

  • 김종수;강성주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1743-1750
    • /
    • 2003
  • DC motor requires a rotor speed sensor for accurate speed control. The speed sensors such as resolvers and encoders are used as a speed detector, but they increase cost and size of the motor and restrict the industrial drive applications. So in these days, many papers have reported in the sensorless operation of DC motor〔3­5〕. This paper presents a new sensorless strategy using neural networks〔6­8〕. Neural network has three layers which are input layer, hidden layer and output layer. The optimal neural network structure was tracked down by trial and error, and it was found that 4­16­1 neural network structure has given suitable results for the instantaneous rotor speed. Also, learning method is very important in neural network. Supervised learning methods〔8〕 are typically used to train the neural network for learning the input/output pattern presented. The back­propagation technique adjusts the neural network weights during training. The rotor speed is gained by weights and four inputs to the neural network. The experimental results were found satisfactory in both the independency on machine parameters and the insensitivity to the load condition.

A possible application of the partial discharge measurement due to artificial defect using Pockets sensor in GIS(Gas Insulated Switchgear) (가스절연기기(GIS)의 인위적 결함에 의한 부분방전의 검출을 위한 Probe-Type Pockels Sensor의 적용 가능성)

  • Ryu, Cheol-Hwi;Lee, Jae-Ho;Ma, Ji-Hoon;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1770-1772
    • /
    • 2003
  • 본 연구는 국내에서 최초로 제안되고 적용가능성이 입증되어 설계, 제작된 Probe-type Pockets sensor(HY-Pockets Sensor)를 GIS등의 고전압 장비들에 응용한 레이저 부분방전 진단 시스템 개발을 목표로 하고 있다. 이러한 목적으로, 170kV 급 실 규모 GIS내부의 전류 도체에 다양한 곡률 반경의 침 전극을 부착시켜 부분 방전에 기인된 불평등 전계를 형성시켜 개발된 센서의 실규모 적용 가능성을 고찰하였다. 본 레이저 계측 시스템은 He-Ne laser, single multi-mode optical fiber, $2{\times}2$ 50/50 laser to single mode fiber coupler, probe-type Pockets sensor, photo detector 등으로 구성하여 레이저의 진행을 유도하고, 신호의 특성을 분석하였다. probe-type Pockets sensor로부터 의 출력 신호는 photo detector를 통해 전기적 신호로 변환되어 digital oscilloscope에 의해 측정되고, 또한 PC를 통해 데이터의 저장과 통계적, 분석적 처리 과정을 수행하게 된다. 본 연구의 결과로서 부분방전원에서 생성된 방전 신호에 대한 거리에 따른 센서 감도 결정, 그에 대한 센서 감도의 보정 향상, 전계의 세기의 변화에 따른 센서의 선형성 등이 도출되었고, 이러한 실험결과를 통해 실 GIS(170kv급) 내부에서 발생하는 부분방전의 검출에 본 레이저 부분방전 진단 시스템의 적용 가능성이 제시 되었다.

  • PDF

MASK ROM IP Design Using Printed CMOS Process Technology (Printed CMOS 공정기술을 이용한 MASK ROM 설계)

  • Jang, Ji-Hye;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.788-791
    • /
    • 2010
  • We design 64-bit ROM IP for RFID tag chips using printed CMOS non-volatile memory IP design technology for a printed CMOS process. The proposed 64-bit ROM circuit is using ETRI's $0.8{\mu}m$ CMOS porocess, and is expected to reduce process complexity and cost of RFID tag chips compared to that using a conventional silicon fabrication based on a complex lithography process because the poly layer in a gate terminal is using printing technology of imprint process. And a BL precharge circuit and a BL sense amplifier is not required for the designed cell circuit since it is composed of a transmission gate instead of an NMOS transistor of the conventional ROM circuit. Therefore an output datum is only driven by a DOUT buffer circuit. The Operation current and layout area of the designed ROM of 64 bits with an array of 8 rows and 8 columns using $0.8{\mu}m$ ROM process is $9.86{\mu}A$ and $379.6{\times}418.7{\mu}m^2$.

  • PDF

A Classification of lschemic Heart Disease using Neural Network in Magnetocardiogram (심자도에서 신경회로망을 이용한 허혈성 심장질환 분류)

  • Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2137-2142
    • /
    • 2016
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. In this study, the signals obtained magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUID) system, and the clinical significance of various feature parameters has been developed MCG. Neural network algorithm was used to perform the classification of ischemic heart disease. The MCG signal was obtained to facilitate the extraction of parameters through a process of pre-processing. The data used to research the normal group 10 and ischemic heart disease group 10 with visible signs of stable angina patients. The available clinical indicators were extracted by characteristic point, characteristic interval parameter, and amplitude ratio parameter. The extracted parameters are determined to analysis the significance and clinical parameters were defined. It is possible to classify ischemic heart disease using the MCG feature parameters as a neural network input.

Design Methodology of Communication & Control Device for Smart Grid Power Facility based on DSP and Raspberry Pi (DSP와 라즈베리 파이를 기반으로 한 스마트 그리드 전력설비의 통신제어장치 설계 방법론)

  • Oh, Se-Young;Lee, Jun-Hyeok;Lee, Sae-In;Park, Chang-Su;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.835-844
    • /
    • 2021
  • In this paper, a power facility communication control device was designed to autonomously determine and separate the fault section through communication between power facilities in the smart grid distribution system. In the power facility communication control device, the control module was designed as a DSP to measure three-phase voltage and current, and the communication module was designed as an embedded-based Raspberry Pi to determine the fault section and realize the fault section separation through communication between power facilities. Communication between DSP and Raspberry Pi was designed by SPI communication, and communication between Raspberry Pi was designed based on Wi-Fi. Finally, a performance evaluation system based on three power facility communication control devices was built, and simulation verification was conducted for various fault events that may occur on the distribution line. As a result of the test evaluation, it was possible to confirm the effectiveness of the design methodology of the communication control device by showing the required response of the communication control device to all test cases.

Block Media Communication System for Implementation of a Communication Network in Welding Workplaces (용접 작업장 통신네트워크 구축을 위한 블록매체통신시스템)

  • Kim, Hyun Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.4
    • /
    • pp.556-561
    • /
    • 2022
  • In this paper, we present a block media communication (BMC) system which employs powerline communication to the equipments used in the welding process for ship-assembly and uses metal block as a communication medium. Inductive couplers are installed on digital feeder and pin jig. Information signal is added to the current generated by the welding gun, and applied to the block. When the welding operation starts, information generated in the field is transmitted to the monitoring server in real-time. The field test on the BMC system confirms that the transmitted data are correctly received at the server. Since the proposed system can be built without any changes to the existing welding process, it is helpful to increase competitiveness of the shipbuilding industry through smart factory of shipyards. It is also possible to quickly respond to emergency situations that may occur to workers in an electromagnetic wave shielding environment or a closed space, the effect of preventing industrial accidents will be great.

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.