• Title/Summary/Keyword: 전력 관리 시스템

Search Result 1,238, Processing Time 0.029 seconds

Low-power Buffer Cache Management for Mixed HDD and SSD Storage Systems (HDD와 SSD의 혼합형 저장 시스템을 위한 절전형 버퍼 캐쉬 관리)

  • Kang, Hyo-Jung;Park, Jun-Seok;Koh, Kern;Bahn, Hyo-Kyung
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • A new buffer cache management scheme that aims at reducing power consumption in mixed HDD and NAND flash memory storage systems is presented. The proposed scheme reduces power consumption by considering different energy-consumption rate of storage devices, I/O operation type (read or write), and reference potential of cached blocks in terms of both recency and frequency. Simulation shows that the proposed scheme reduces power consumption by 18.0% on average and up to 58.9%.

A Study on Energy Management System for Energy Saving in Building (건물 에너지 저감을 위한 에너지 관리 체계 연구)

  • Kang, Hyun-Jun;Park, Jae-Hyun;Park, Jong-Tae;Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.7
    • /
    • pp.787-792
    • /
    • 2015
  • In this paper, We described the implementation of the Smart Gateway for heterogeneous interface integrated, Web Server and Building Energy Management System(: BEMS). The proposed system introduces the reduction of peak power and electric power usage with service model and operating algorithm for energy saving in building.

Controllable Load Management In A Competitive Electricity Market (경쟁적 전력시장의 부하관리 시스템에 관한 연구)

  • Kim, Jin-Ho;Han, Tae-Kyung;Nam, Young-Woo;Park, Jong-Bae;Kim, Bal-Ho H.;Park, Jong-Keun;Seo, Jang-Chul;Lee, Jin-Ho;Choi, Jong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.41-43
    • /
    • 2001
  • 경쟁적 전력시장의 도입으로 시장의 모든 참여자들은 자신의 효용이나 수익을 극대화하게 된다. 이에 따라 수용가들은 효용극대화 및 비용최소화를 위한 적극적인 전력소비전략을 필요로 하게 되며, 이를 위해 경쟁적 시장의 부하관리 시스템에 대한 관심이 증가하고 있다. 본 논문에서는 경쟁적 전력시장의 에너지비용절감을 위한 부하관리시스템의 국내외 연구 동향 및 사례들을 조사 분석하였으며 이를 바탕으로 국내 적용 가능성 등을 연구하였다.

  • PDF

Development of Energy Management System (에너지관리, 제어 시스템(EMS) 개발)

  • Lee, J.Y.;Choi, Y.S.;Shin, C.G.;Chung, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.854-857
    • /
    • 1998
  • 에너지관리, 제어 시스템(EMS)은 전력계통의 실시간 제어 및 총체적인 관리를 최대화하기 하여 컴퓨터 및 통신 시스템으로 구축된 제어시스템이다. 본 EMS의 주요특성은, 첫째 상당히 빠른 속도로 발전되는 컴퓨터 및 통신 기술들을 수시로 수용할 수 있는 기능, 둘째 상대적으로 지속적이며 오래토록 사용되는 수학적인 알고리즘 및 Buiness Rule들을 처리하는 소프트웨어를 급변하는 Computing 환경에서 적응해 갈 수 있는 기능, 셋째 Heterogenous한 시스템에 접속시킬 수 있는 Database를 갖추었다. 끝으로, 대형 전력계통의 Modeling과 이에 부합하는 실시간 Data로 자동화된 전력계통 실시간 운영상의 결과들을 해석 및 검증하였다.

  • PDF

Development of Electric Power Management System for Electric Furnace (전기로 전력관리 시스템 개발)

  • Min, Byeong-Yong;Kim, Ho-Jin;Kwon, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.904-907
    • /
    • 2013
  • Demand Controller is a control device that if current electric power consumption seems to exceed the targeted amount of electric power, block the connected load devices. When this ON/OFF way is applied to electric power management of electric furnace, start and stop operation of inverter and an electric heater which supplying electric power is being performed repeatedly. This has a problem of life-shortening of inverter and an electric heater by electrical damage. In addition, when electric power supplying is blocked, attemperation is not allowed until return to normal operation condition. In this paper, we develop power management system for electric furnace using the electric furnace remote controller. This system provides the automatic control for approved electric power to electric furnace organically and prevent electric damage of inverter and an electric heater through continuous electric power supply within the targeted amount of electric power.

  • PDF

Development a Distributed Power Information System Based on Event using XML (XML을 이용한 이벤트 기반 분산 전력 정보 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.8
    • /
    • pp.89-96
    • /
    • 2009
  • In the future energy environment, a power information system will meet the real-time capability to process the emergency events, unexpected blackouts or over-load, and the high performance to provide the consumer service events such as remote meter reading. In addition to, it must have facility which is able to process a large information occurred on system effectively. In this paper, we developed a distributed power information system based on event with metadata processing technique which was both load balancing and decreased hot spot using XML that was efficient for information exchange. In order to experiment, we made a reduced future power system with controling power device using wireless communications and we could do experiments through it.

The Design of Value added Service Model of Power Utility using PowerLine Carrier (전력선통신을 이용한 전력 부가 서비스 시스템의 개발)

  • Park, Byung-Seok;Hyun, Duck-Hwa;Cho, Seon-Ku;Oh, Myun-Tack
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2711-2713
    • /
    • 2003
  • 본 논문에서는 수요관리, 원격검침, 심야전력관리, 고객 부가서비스 등 여러 서비스를 단일 전력선 통신망을 이용한 지능형 전력부가 서비스 시스템을 설계하였다. 설계된 시스템은 저압 수용가에 다양한 편리 서비스를 제공함과 동시에 수용가의 전력 에너지이용을 효과적으로 하도록 유도할 수 있으며, 다수의 수용가를 하나의 통신망으로 연결하여 경제성이 우수하다.

  • PDF

A Study on Development and Operation of Power Energy Consumption Consulting System (전력에너지 컨설팅 시스템 개발 및 운영방안 연구)

  • Kim, Sun-Ic;Yu, In-Hyeob;Ko, Jong-Min;Jung, Nam-Jun;Cho, Sun-Gu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.544-546
    • /
    • 2007
  • 본 연구에서는 전력부가서비스 시스템으로 개발한 전력에너지 컨설팅 시스템의 주요 기능과 운영방을 소개한다. 본 시스템의 주요 기능은 전력소비 데이터 분석, 전력사용량 분석, 전력요금 분석, 전력요금 컨설팅 보고서 제공 등 4가지로 구분할 수 있다. 원격검침을 시행중인 고압고객 중 계약전력이 100kW 이상인 대수용가로부터 특히, 전력요금 절감을 필요로 하지만 별도의 설비나 인력을 보유하지 않은 10,000kW 이하 고객을 적용대상으로 하고 있다. 본 시스템은 수용가에게는 전력요금 절감을 전력회사 및 Energy Service Provider에게는 간접적 부하/수요관리 효과를 목표로 개발하였으며, 향후 대수용가를 대상으로 전력부가서비스 적용 사업화 분야에 활용될 수 있을 것이다.

  • PDF

Development of DC Microgrid Management System Based on Intelligent Agent Systems (지능형 에이전트 기반의 직류 마이크로그리드 관리시스템 개발)

  • Chio, Min-Seok;Hai, Trinh Phi;Cho, Hector;Chung, Il-Yop;Kim, Ju-Yong;Cho, Jin-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.517-518
    • /
    • 2015
  • 본 논문에서는 저압 직류(LVDC) 마이크로그리드(Microgrid)의 배전가능거리와 분산전원 수용률을 증대하기 위한 지능형 에이전트 기반의 전압 제어 기법에 대해서 설명한다. 제안하는 방법은 분산전원에 설치된 지능형 제어노드에서 자율적인 전압, 전류, 전력측정을 수행하고 이러한 데이터를 바탕으로 전압제어 민감도를 산출하며 실시간 모니터링 데이터와 함께 중앙 관리시스템으로 전송된다. 중앙 관리시스템은 교류계통과 연계되는 주(Main) AC-DC 전력변환기와 각 분산 전원과의 협조제어를 통해 마이크로그리드의 전압을 실시간으로 제어한다. 제안하는 전압제어 원리의 구현을 위해 본 논문은 지능형 에이전트 기반의 직류 마이크로그리드 관리시스템에 대해서 설명한다. 개발된 마이크로그리드 관리시스템은 실시간 OS를 탑재한 범용 임베디드 시스템 하드웨어로 구성되며 이더넷 통신을 이용하여 멀티-에이전트 네트워크를 구성한다.

  • PDF

Dynamic Power Management Framework for Mobile Multi-core System (모바일 멀티코어 시스템을 위한 동적 전력관리 프레임워크)

  • Ahn, Young-Ho;Chung, Ki-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.52-60
    • /
    • 2010
  • In this paper, we propose a dynamic power management framework for multi-core systems. We reduced the power consumption of multi-core processors such as Intel Centrino Duo and ARM11 MPCore, which have been used at the consumer electronics and personal computer market. Each processor uses a different technique to save its power usage, but there is no embedded multi-core processor which has a precise power control mechanism such as dynamic voltage scaling technique. The proposed dynamic power management framework is suitable for smart phones which have an operating system to provide multi-processing capability. Basically, our framework follows an intuitive idea that reducing the power consumption of idle cores is the most effective way to save the overall power consumption of a multi-core processor. We could minimize the energy consumption used by idle cores with application-targeted policies that reflect the characteristics of active workloads. We defined some properties of an application to analyze the performance requirement in real time and automated the management process to verify the result quickly. We tested the proposed framework with popular processors such as Intel Centrino Duo and ARM11 MPCore, and were able to find that our framework dynamically reduced the power consumption of multi-core processors and satisfied the performance requirement of each program.