A Low-Power Design and Implementation of the Portable Device for Measuring Temperature and Humidity Based On Power Consumption Modeling (소비 전력 모델링에 입각한 휴대용 온습도 측정기의 저전력 설계 및 구현)

  • Lee, Chul-Ho;Hong, Youn-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1027-1035
    • /
    • 2014
  • The most important design factor for portable devices is power consumption. In this paper, in the early design stage of a mobile device which measures temperature and humidity a power consumption model will be proposed and then the overall power consumption will be estimated based on this model. We will verify previously the correctness of such estimated power consumption before implementation of the real device. That is our proposed design methodology based on power consumption model. An improved design method for efficiently reducing the current consumption in the idle mode is also presented. By implementing a real prototype of the mobile device for measuring temperature and humidity, the correctness of our proposed design methodology based on power consumption modeling will be verified.

Prediction Method about Power Consumption by Using Utilization Rate of Resources in Cloud Computing Environment (클라우드 컴퓨팅 환경에서 자원의 사용률을 이용한 소비전력 예측 방안)

  • Park, Sang-myeon;Mun, Young-song
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Recently, as cloud computing technologies are developed, it enable to work anytime and anywhere by smart phone and computer. Also, cloud computing technologies are suited to reduce costs of maintaining IT infrastructure and initial investment, so cloud computing has been developed. As demand about cloud computing has risen sharply, problems of power consumption are occurred to maintain the environment of data center. To solve the problem, first of all, power consumption has been measured. Although using power meter to measure power consumption obtain accurate power consumption, extra cost is incurred. Thus, we propose prediction method about power consumption without power meter. To proving accuracy about proposed method, we perform CPU and Hard disk test on cloud computing environment. During the tests, we obtain both predictive value by proposed method and actual value by power meter, and we calculate error rate. As a result, error rate of predictive value and actual value shows about 4.22% in CPU test and about 8.51% in Hard disk test.

LoRa based Water Level Measurement System (LoRa 기반 수위 측정 시스템)

  • Kim, La-Hee;Kim, Hee-Joo;Lee, Sang-Rok;Jo, Ohyun
    • Annual Conference of KIPS
    • /
    • 2019.10a
    • /
    • pp.331-334
    • /
    • 2019
  • 본 논문에서 소개하는 LoRa 기반 IoT 네트워크를 이용한 수위측정기는 저전력/저비용 오픈 하드웨어를 이용하여 구현하였다. 이 수위 측정기는 LoRa 네트워크를 통해 넓은 커버리지를 저전력으로 지원가능하며 기존 수위측정기보다 저렴하다는 장점이 있다. 또한, 상황에 따라 전력 소모를 최적화하기 위해 데이터베이스 업데이트 주기를 조정할 수 있다. 이를 기반으로 사용자는 웹페이지를 통해 실시간 수위현황과 주간별 수위현황을 알 수 있고, 범람 단계별 행동 요령을 파악할 수 있다.

A Study on Power Dissipation of The Microprocessor Based on Trace-Driven Simulation (명령어 자취형 모의실험을 기반으로 하는 마이크로프로세서의 전력 소비에 대한 연구)

  • Lee, Jongbok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.191-196
    • /
    • 2016
  • Recently, power dissipation is a very significant issue not only in embedded systems and mobile devices but also in high-end modern processors. Especially, by the prevalent use of smart phones and tablet PCs, low power consumption of microprocessors is requisite. In this paper, a fast power measurement tool for a high performance microprocessor based on the trace-driven simulator has been developed. The power model of the microprocessor consists of complex combinational circuits, array structures, and CAM structures. Using SPEC 2000 benchmarks as input, the trace-driven simulation has been performed to estimate the average power dissipation of each program.

전력기기 내부의 부분방전 측정시 방전형태의 분석에 대해서

  • 조연옥;김광화
    • 전기의세계
    • /
    • v.36 no.10
    • /
    • pp.707-712
    • /
    • 1987
  • 본고에서는 절연체 내부에서 일어나는 부분방전에 대해서 간략하게 검토한후, 부분방전의 측정 및 대표적인 전력기기의 부분방전 허용치에 대해서 논하고자 하였다. 특히 부분방전의 측정 부분에서는 부분방전 측정기의 오실로스코프 상에 나타난 펄스 파형 해석에 중점을 두어, 기기 외부에서 발생하는 잡음에 의한 오실로스코프 상의 펄스 파형을 구분하게 함으로써 정확한 부분방전의 측정에 도움을 주고자 하였다.

  • PDF

Development schemes of IoT Water Quality Metering device linked with a Drone (드론 연계 무인 IoT 수질 측정기 개발 방향)

  • Rhee, Dong Sop;Seong, Hoje
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.223-223
    • /
    • 2020
  • 하천 조사에 드론의 필요성은 점차 증가하고 있으며, 하천시설 조사 및 하천 물리량 간접 계측 등에 있어서 활용성 또한 증가하고 있다. 드론을 이용한 하천시설 및 하천 조사는 주로 광학 영상에 기초한 간접 계측을 중심으로 활발히 기술 개발이 진행되고 있으며, 최근에는 적용하는 임무장비를 확장하여 초분광카메리나 LiDAR 등을 활용하려는 시도가 활발히 이루어지고 있으며, 관련 기술의 개발도 역시 급격히 진행되고 있다. 이러한 기술 발전을 통해 하천 조사에 있어서 간접 계측의 정확도는 계속하여 증가하고 있으나, 기술의 편리성이나 활용성에 비해 정확도 향상에는 어느 정도 한계가 있으며, 간접 계측에 의한 정확도를 확보하기 위해서는 여전히 직접 계측 결과와 비교를 통한 검보정이 필수적이다. 직접 계측은 첨단 계측기를 사용한다고 하더라도 아직까지 인력에 의한 의존도가 높으며, 측정 효율이 여전히 떨어지고 있어 간접 계측의 편리성을 저하시키는 원인으로 작용하고 있다. 본 연구에서는 드론 기반의 간접 계측이 편리성 및 활용성, 정확도를 올리 수 있는 무인 IoT 수질 측정기를 개발하고자 한다. 무인 IoT 수질 측정기는 드론에서 측정한 자료 검보정 자료 획득을 목표로 하며, 드론으로 측정한 지역에 대한 데이터 검보정 정확도를 향상 시킬 수 있는 측정방안을 고려하고 있으며, 현재 이용 가능한 IoT 통신 모듈의 적용성 및 통신 거리를 고려하여 개발을 진행하고 있다. 특히 데이터 전송을 고려하여 개별 통신 규약 검토를 진행하였으며, 각종 표준을 검토하였다. 통신을 위한 전력 소모를 고려하여 저전력 통신 모듈을 중심으로 검토를 진행하였으며, 하천의 특성을 고려한 수질 측정 지점 결정을 위한 측정 알고리즘을 개발하여 적용하였다.

  • PDF

A Study on the Definition and the Measuring Method of Average Coupled Power in Optical Transmitters (광송신기에서의 평균결합전력 정의 및 측정방법 연구)

  • Jang, Dong-Won
    • Electronics and Telecommunications Trends
    • /
    • v.10 no.4 s.38
    • /
    • pp.155-163
    • /
    • 1995
  • 본 고에서는 광통신 시스템 송신단에 영향을 주는 파라미터를 분류하고 기술하였다. 광통신 시스템을 안정적으로 운영하기 위해서는 성능 관련 파라미터에 대한 기준값을 정해야 한다. 본 고에서는 송신단의 기준 파라미터로 평균결합전력을 선정하고 이 값에 영향을 주는 요인들을 분석했으며, ITU-T에서 권고한 평균결합전력값을 분석하였다. 또한 측정기를 이용하여 실제로 평균결합전력을 측정하는 방법에 대해서도 기술하였다.

Development of a portable device for the measurement of urea concentration and glucose concentration in blood (혈중요소 및 혈당농도 측정을 위한 휴대용 측정기 개발)

  • Yoo, Jae-Tack;Lee, Dong-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.28-32
    • /
    • 2003
  • 본 논문은 시료의 양을 최소화하고 혈중 요소 및 혈당 농도에 대한 정확한 측정을 위하여 최근에 개발된 전기화학형 마이크로 전극형 센서의 간략한 소개 및 전기적인 특성에 관하여 요약하는 것에서 출발하여 센서로부터 전기신호를 발생시키는 signal conditioning 회로의 설계, microprocessor를 이용한 digital 값으로의 변환 및 data 취득, 취득한 data를 측정된 혈당량 및 요소량으로의 변환 저장 display까지의 휴대용 계측기의 prototype 개발에 관하여 기술한다. 이 계측기는 미량의 혈액채취 한번으로 농도를 측정하는 측정모드와, 측정된 data를 찾아보기 위한 검색모드로 작동시킬 수 있다. Microprocessor의 기능을 최대한 사용하여 측정기의 크기를 소형화하였으며 LCD(Liquid crystal display)틀 채택하는 등 저전력 회로로 구현하였다.

  • PDF