• Title/Summary/Keyword: 전력정보제어

Search Result 1,117, Processing Time 0.028 seconds

Development of 4MW Class High Voltage Inverter System (4MW급 고압 인버터 시스템 개발)

  • 박영민;한기준;최세경;정명길;이세현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.432-437
    • /
    • 2001
  • This paper describes a new developed 3.3KV/4MW class three-level Voltage Source Inverter(VSI), which is equipped with IIMS(Inverter Information Management System) based on the world wide web and with the Virtual operation simulator. The algorithm for motor control is the stator oriented Direct Torque Control(DTC), which works without speed sensor and gives the physically fastest dynamic response. The IIMS have the functions of operation monitoring and data managements. Virtual operation simulator can analyze and tune the system characteristics without main power. Now, this system is under the field test to verify the confidence.

  • PDF

Performance Evaluation of Time Hopping Pulse Position Modulated Ultra-Wideband System for Home Sensor Network (홈 센서 네트워크를 위한 주파수 도약 펄스 위치 변조된 초 광대역 시스템의 성능 평가)

  • Roh, Jae-Sung
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.3
    • /
    • pp.268-275
    • /
    • 2006
  • The rapid proliferation of in-home and office information applications and services is driving the need for new wireless technologies enabling wideband short range multimedia communications. Due to the growing demand for higher quality media and faster wireless connections, several IEEE standardization groups are considering very high data rate alternatives physical layer(s) for Wireless Personal Area Network (WPAN). The Ultra Wide Band (UWB) multiple access technology based on very narrow pulse transmission, is one viable candidate for these applications providing very high bit rates services, low power consumption and accurate positioning capability. In this paper we provide a methodology to evaluate the UWB system BER performance in UWB wireless fading networks with power controlled UWB devices are considered. Results can be used to analyze the performance of a given network topology and to provide useful design ideas for an UWB home sensor network.

  • PDF

Initial Rotor Position Detection of Single-phase Permanent Magnet Synchronous Motor using Offset Voltage (옵셋 전압을 이용한 단상 영구자석 동기 전동기의 초기 회전자 위치 검출)

  • Hwang, Seon-Hwan;Seo, Sung-Woo;Jung, Tae-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.622-627
    • /
    • 2019
  • This paper propose an initial rotor position detection method for sensorless operation of a single-phase permanent magnet synchronous motor(SP-PMSM) with asymmetric air-gap. In general, the sensorless control based on back-emf estimation is difficult to estimate the back-emf at the zero and low speed regions. For this reason, an open loop start-up technique is indispensable, and it is also necessary to detect the initial position of the rotor in order to rotate in a certain direction. In this paper, we propose a method to detect rotor polarity by adding offset voltage to high frequency voltage signal based on the magnetic characteristics of SP-PMSM. The validity and usefulness of the proposed algorithm are verified through several experimental results.

On Flexibility Analysis of Real-Time Control System Using Processor Utilization Function (프로세서 활용도 함수를 이용한 실시간 제어시스템 유연성 분석)

  • Chae Jung-Wha;Yoo Cheol-Jung
    • The KIPS Transactions:PartA
    • /
    • v.12A no.1 s.91
    • /
    • pp.53-58
    • /
    • 2005
  • The use of computers for control and monitoring of industrial process has expanded greatly in recent years. The computer used in such applications is shared between a certain number of time-critical control and monitor function and non time-critical batch processing job stream. Embedded systems encompass a variety of hardware and software components which perform specific function in host computer. Many embedded system must respond to external events under certain timing constraints. Failure to respond to certain events on time may either seriously degrade system performance or even result in a catastrophe. In the design of real-time embedded system, decisions made at the architectural design phase greatly affect the final implementation and performance of the system. Flexibility indicates how well a particular system architecture can tolerate with respect to satisfying real-time requirements. The degree of flexibility of real-time system architecture indicates the capability of the system to tolerate perturbations in timing related specifications. Given degree of flexibility, one may compare and rank different implementations. A system with a higher degree of flexibility is more desirable. Flexibility is also an important factor in the trade-off studies between cost and performance. In this paper, it is identified the need for flexibility function and shows that the existing real-time analysis result can be effective. This paper motivated the need for a flexibility for the efficient analysis of potential design candidates in the architectural design exploration or real time embedded system.

Memory Architecture Design and Experiments for Image Real-Time Transmission in Zigbee Environment (Zigbee환경에서 이미지의 실시간 전송을 위한 메모리 구조 설계 및 그 실험)

  • Lim, Hee-sung;Lee, Jong-sung;Lee, Kang-whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.589-591
    • /
    • 2009
  • 본 논문에서 제안하고 있는 RT-WISN(Real Time-Wireless Image Sensor Network)는 과거의 무선이미지 전송 기술에 비해 적은 전력을 소모하고 빠른 전송이 가능하게 하는 기술이다. 제안된 RT-WISN은 IEEE802.15.4 표준을 따르고 있으며, 현재 본 연구실에서 개발하고 있는 UoC(Ubiquitous on Chip) 메모리 구조를 응용하여 사용하고 있다. 본 논문에서 제안하고 있는 RT-WISN은 전송하고자 하는 대상이 되는 영상정보의 움직임 변화를 영상 전송 임계값 값을 사용하여 데이터 전송 시기를 결정함으로써 기존의 시스템에 비해 노드의 에너지를 보다 효율적으로 관리할 수 있는 기법 이다. 또한 본 논문에서는 제안된 전용 프로세서를 사용하여 보다 넓은 대역폭에서 필요한 영상 데이터를 효율적으로 전송할 수 있어 전송 시간 제어에 보다 용이함을 제공 한다. 무선센서 네트워크에서 이런 점들은 각 노드들의 생존 시간을 향상하게 되고, 고속의 전송이 가능하게 하는 장점으로 작용하게 된다. 본 논문에서는 Peer-to-Peer 상에서 실제 설계된 메모리 구조를 사용하여 이미지를 무선으로 전송하고 그 전송 시간과 도달률을 측정하여 RT-WISN이 무선 센서 네트워크에서의 검출된 영상 정보의 전송에 적합함을 보인다.

  • PDF

A Flexible Multi-Threshold Based Control of Server Power Mode for Handling Rapidly Changing Loads in an Energy Aware Server Cluster (에너지 절감형 서버 클러스터에서 급변하는 부하 처리를 위한 유연한 다중 임계치 기반의 서버 전원 모드 제어)

  • Ahn, Taejune;Cho, Sungchoul;Kim, Seokkoo;Chun, Kyongho;Chung, Kyusik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.9
    • /
    • pp.279-292
    • /
    • 2014
  • Energy aware server cluster aims to reduce power consumption at maximum while keeping QoS(quality of service) as much as energy non-aware server cluster. In the existing methods of energy aware server cluster, they calculate the minimum number of active servers needed to handle current user requests and control server power mode in a fixed time interval to make only the needed servers ON. When loads change rapidly, QoS of the existing methods become degraded because they cannot increase the number of active servers so quickly. To solve this QoS problem, we classify load change situations into five types of rapid growth, growth, normal, decline, and rapid decline, and apply five different thresholds respectively in calculating the number of active servers. Also, we use a flexible scheme to adjust the above classification criterion for multi threshold, considering not only load change but also the remaining capacity of servers to handle user requests. We performed experiments with a cluster of 15 servers. A special benchmarking tool called SPECweb was used to generate load patterns with rapid change. Experimental results showed that QoS of the proposed method is improved up to the level of energy non-aware server cluster and power consumption is reduced up to about 50 percent, depending on the load pattern.

A Study on the Interface between DAS and SCADA by using Direct Method (직접연계방법에 의한 DAS-SCADA 연계 연구)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1154-1163
    • /
    • 2008
  • DAS and SCADA system are main systems, which operate and manage the power system by using computer and communication technology. But DAS and SCADA have been operated independently in Korea, so there was some time delay in the fault handling and live-line work. To improve that problems, studies on the interface between DAS and SCADA have been needed. From November 2005 to December 2007, the pilot project has been performed in KEPCO's branch offices, as a result, direct method will be applied widely all over the country until 2010 because the operation information of substation users want can be transmitted fast and it is possible to control 43RC directly although the expense for direct method is about 1.3 times larger than that for web method. To improve problems revealed during the pilot project, substation object to object communication method is proposed and interface database automatic generation and interface system diagnosis and logging functions are developed. Interface data point and communication data type are defined, substation single line diagram automatic generation or manual editing function, SCADA monitoring and controlling function, log data managing function are developed in SCADA HMI program. It is expecting to reduce the average time for each outage about 33% and to improve the reliability, efficiency of operation, execution of DAS from automatic load transfer under a fault, and to contribute to export project.

The Grounding Method Application of Power Plant Simulator (발전소 시뮬레이션시스템 접지방식 연구를 위한 타시스템 접지방식 분석)

  • 오영일
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.70-74
    • /
    • 1999
  • 발전소 시뮬레이션 시스템 기술은 종합적인 지식을 바탕으로 자료수집 및 분석, 소프트웨어 개발 환경, 수학적 모델, 전산기 구성, 각종 계기류 설계 및 구매 장착 등의 노하우를 알아야만 제작할 수 있는 종합적인 기술이다. 또 지시기반의 기술이며 부가가치가 높은 기술이기 때문에 선진 각국에서는 계측제어 시스템의 기술개발 및 시장 확대를 위하여 힘을 쓰는 동시에 타국으로의 기술정보 유출을 경계하는데 신경을 곤두세우고 있다. 현재 복잡화되어 가고 있는 산업 사회의 전력 수요에 대한 대폭적인 증가 추세에 따라 발전소에서는 보다 효율적이며 합리적이고 경제적인 전력 공급을 위해서 전력 생산에 대한 신뢰성 향상 및 안정성 확보는 물론, 효율성 높은 운전이 절실히 요구되고 있다. 한편, 국내의 시뮬레이션 시스템 분야 기술은 아직도 완벽한 수준에는 미치지 못하며, 이 분야의 기술력 확보 및 신기술 개발은 향후 미래의 모든 시스템산업의 성쇄를 판가름하는 아주 중요한 척도가 될 것이다. 이 중에서 접지 분야는 고전압 혼촉에 의한 저압측 선로의 전압상승 방지, 모선(Bus)이나 전력 기기의 절연보호 및 회로전압의 안정등으로 시스템 성능을 한층 증가 시켜줄 뿐아니라 기기의 오동작이나 낙뇌등으로 인명피해 발생을 없애주는 아주 중요한 분야임에도 불구하고 이 분야의 국내 관련법규등이 미비한 사항이다. 그래서 발전소 분산제어 시스템분야의 장기간 신뢰성 및 안정성을 가지고 있고, 국내에서 많이 사용하는 미국 Bailey의 infi-90 및 독일 ABB의 Procontrol-P를 비교 분석하여 발전소 시뮬레이션 시스템의 접지에 응용 하고져 한다.상호 발생기를 이용한 다양한 시스템 검증 및 분석에 이용할 수 있을 것이다. 본 논문은 가상호 발생기의 구조와 최대 용량 시험 방법을 소개하고, 더 나아가 호 Traffic에 대한 최대 용량 시험뿐 아니라 QoS를 향상시키기 위한 교환 시스템의 제반 성능 시험 및 분석에 이를 이용하기 위해 개선이 필요함을 서술하고자 한다.textrm{m}$~3.4$\mu\textrm{m}$ 범위에서의 투과 및 흡수 스펙트럼을 측정하였다. 결정 성장 결과 B3+, Er3+, Cr3+ 이온은 Ti4+ 이온과 이온의 크기 차이가 심하여 결정의 정상적인 성장을 방해하는 물성을 나타냈고, V5+, Cr3+ 이온은 흑색의 결정, Fe3+ 이온은 적갈색의 결정으로 성장되었다. Al3+, Zr4+, Al3+의 순서로 투과도가 높아지는 것이 관찰되었다. 불순이온의 농도에 따른 영향으로서 Al3+ 이온의 경우 주입농도가 높아질수록 low angle boundary와 oxygen deficiency가 감소하였고, 투과율은 조금 감소하거나 큰 차이가 없는 것으로 나타났다. 반면에 Cr3+ 이온을 주입한 경우 0.003 atomic%에서 최적의 물성을 보였으며, 주입농도가 높아질수록 결정성장이 어려워지고 광의 투과도가 급격히 저하되었다.은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인

  • PDF

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

A Multi-Protocol Gateway Middleware Design on Ubiquitous Sensor Networks (USN 기반 다중 프로토콜 게이트웨이 미들웨어 설계)

  • Hong, Sung-Il;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.11
    • /
    • pp.895-901
    • /
    • 2013
  • In this paper we propose design of a multi-protocol gateway middleware based on USN. The proposed multi-protocol gateway middleware defined the transmit messages format, and were used the USN module interface protocol for connect to external application MCU using the UART. In this case, the gateway was checks the communication state of Zigbee module with settings information, and setting Zigbee serial PDU format. The experimental results of the proposed multi-protocol gateway middleware were proved the efficiency of integrate protocol gateway to use the multi-protocol gateway than gateway to using the repeater through the power control and communications a controlled experiment.