• Title/Summary/Keyword: 전력사

Search Result 431, Processing Time 0.03 seconds

A Selection Model For Power Plant Project Delivery Method (화력발전소 발주방식 비교를 통한 적정 발주방식 선정 모형)

  • Kim, Sun-Kuk;Park, Jong-Kyoo;Park, Chan-Sik;Son, Ki-Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.1 s.35
    • /
    • pp.66-77
    • /
    • 2007
  • With the electricity industry structure reformation of the government in April, 2001, Korea Power Electric Corporation was divided in to Korea water power nuclear power and 5 thermal power plant. After, various delivery method is introduced and applied for active profit creation according to the competition between each development companies for the public company privatization. However, the current situation does not satisfy the project participant by selecting the delivery method without reflecting the business goal and project characteristics of power plant construction business. The objective of this study is to research the influencing factors that should be considered to select the delivery method in thermal power construction business and develop a standard of selection of appropriate delivery method through questionnaire and interviews to establish a model to select the delivery method that fits the business goal of the subject of delivery. In the future, if the delivery method selection model suggested in this study is applied, it is expected to select the appropriate delivery method of power plant construction business by effectively reflecting the business goal, characteristics and demand of the delivery subject, and characteristics of the construction business apart from the existing customary practices that decided the delivery method dependent on the subjective and experience based judgement.

Frequency Recognition in SSVEP-based BCI systems With a Combination of CCA and PSDA (CCA와 PSDA를 결합한 SSVEP 기반 BCI 시스템의 주파수 인식 기법)

  • Lee, Ju-Yeong;Lee, Yu-Ri;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.139-147
    • /
    • 2015
  • Steady state visual evoked potential (SSVEP) has been actively studied because of its short training time, relatively higher signal-to-noise ratio, and higher information transfer rate. There are two popular analysis methods for SSVEP signals: power spectral density analysis (PSDA) and canonical correlation analysis (CCA). However, the PSDA is known to be vulnerable to noise due to the use of a single channel. Although conventional CCA is more accurate than PSDA, it may not be appropriate for the real-time SSVEP-based BCI system when it has short time window length because it uses sinusoidal signals as references. Therefore, the two methods are not efficient for the real-time BCI system that requires a short TW and a high recognition accuracy. To overcome this limitation of the conventional methods, this paper proposes a frequency recognition method with a combination of CCA and PSDA using the difference between powers of canonical variables obtained from the results of CCA. Experimental results show that the performance of the combination of CCA and PSDA is better than that of CCA for the case of a short TW.

Analysis of Frequency Response Curve for Conduction-Cooled Power Capacitors (전도 냉각 파워 커패시터의 주파수 응답 곡선 분석)

  • An, Gyeong Moon;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.123-130
    • /
    • 2016
  • High-frequency induction heating equipment can heat the metal by applying a High-Frequency power to the resonant circuit. The resonance circuit is composed of the work coil and the conduction-cooled power capacitor, it influences the performance of the heat treatment equipment according to the characteristics of the capacitor. However, dependence on conduction-cooled power capacitor's import is high due to lack of core technology research and development. Minimizing the generation of internal heat transmitted inside during LC resonance, reduce the reactive power loss, there is a need for a capacitor within the voltage characteristic outstanding. To implement localization it is vital that prior study of the analysis on the frequency response characteristic for the finished capacitor advanced manufacturer be implemented. Studying the interpolation method to read the value at any point of the characteristic curve for a given log-log scale was applied to the analysis tool of the capacitor by my proposed algorithm. The simulation for reproducing frequency response curves was attempted by assuming a capacitor in a simplified series equivalent RC circuit to obtain the equivalent series resistance value. It was confirmed that the reproduction rate was the result value above 83% as compared to the simulation of the properties and characteristics on the actual reactive power for Peak value, and that the algorithm can be applicable when analyzing and predicting the characteristic curves of a simpled model capacitor.

C00rdinated Testing between transformer Tap Selection and Inverter Voilage Control in the PV Distributed Generation system (태양광 분산 발전 시스템의 계통연계용 변압기탭 선정과 인버터전압조정 협조시험)

  • Yoon, kap koo;CHO, SeongSoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1098-1099
    • /
    • 2015
  • ${\bullet}$ 시험대상: 영월태양광 4,990kW(998kW ${\times}$ 5호) ${\bullet}$ 13.07.31 연계기술검토의뢰 ${\bullet}$ 13.08.28 한전검토결과: 인근변전소 영월S/S(40MW) 초과로 10.8km 지점의 평창 D/L 평창간 347호 주진S/S에 다음의 보완대책과 연계 권고 ${\cdot}$ 문제점: 적정전압이탈 및 순시전압변동률 유지불가 ${\cdot}$ 연계기준만족을 위해 한전에서 제시한 보완대책 : 계통용량증설(설비보강), 연계용량 감소 및 전용선로 연계 ${\bullet}$ 14.01.09 분산형설치자의 용역사(에이스기술단)에서 송배전용전기설비 이용규정과 연계기준 만족을 위한 보완대책 제안 ${\cdot}$ 태양광발전시스템 인버터 자동전압(역률/무효전력) 조정기능 및 감시설비 구비 ${\cdot}$ 최적 공통연결점 선정: 분산형전원으로 부터 전기적으로 가장 가까운 영월D/L 영월S/S측에 개폐장치설치 하고 주진S/S 측으로 연계 ${\bullet}$ 14.01.29~06.19 한전(전력연구원)의 유효성 검토 ${\cdot}$ 보완대책 기술적 유효(실증시험 시행 후 시행공문 발송 예정) ${\bullet}$ 14.08.08 송배전용전기설비 이용규정 개정에 따른 협의 ${\cdot}$ 변압기 대당 20MW에서 25MW ${\cdot}$ 변전소 전체 60MW에서 75MW까지 허용 ${\cdot}$ 영월 S/S 측 문곡/영월 D/L 연계 공사 협의 ${\bullet}$ 14.10.04 사용전검사, 한전계통연계운전 시작 ${\bullet}$ 인버터 고정역률(99.9~100%) 운전 시험 ${\cdot}$ 14.11.21 22.9kV 계전기(SEL-751) 5대, 15분 간격 자료저장 ${\cdot}$ SEL-751/USB to RS232C/노트북 15분간격 측정(첨부) ${\bullet}$ 14.03.07 인버터 역률 95.0% 조정 15분간격 측정(첨부) ${\bullet}$ 변압기탭 선정과 인버터전압조정협조시험 계획 ${\cdot}$ 변압기탭을 현장에서 상하 1탭씩 변경 ${\cdot}$ 인버터역률을 인버터공급사에서 원격조정 ${\cdot}$ 22.9kV 보호계전기 SEL-751, 15분 간격 측정 ${\cdot}$ 인버터 370V 계전기 K-PAM DG3000/현장감시설비 연계 ${\cdot}$ 15분 간격 측정 저장 ${\cdot}$ 현장감시설비/인터넷 연결 원격측정(첨부예정)

  • PDF

Plasma Aided Flotation for Removing Organic Substances and Killing Microorganisms

  • Yu, Seung-Min;Hong, Eun-Jeong;Yu, Seung-Yeol;Park, Jun-Seok;No, Tae-Hyeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.122-122
    • /
    • 2014
  • 수중방전을 환경분야에 적용하기 위한 플라즈마 부상법이 개발되었다. 플라즈마 부상법은 물 속에서 발생시킨 플라즈마가 가지고 있는 주요특성 중 물리적 특징인 쇼크웨이브, UV조사, 버블생성 등과 화학적 특징인 OH라디칼 및 염소산화물 생성 등을 이용하여 물 속에 존재하는 용존성 및 입자성 물질을 부상분리 기법으로 제거하는 공법이다. 유기물을 제거하는 기작으로는 침전, 여과, 분해 등이 있고, 이를 구현하기 위한 공정으로 중력침강법, 부상분리법, 멤브레인법, 미생물법 등이 있다. 이 중에서 가압공기부상법은 침강법에 비해 부지면적을 적게 소모하고 처리시간이 50% 이상 감소되는 특징이 있다. 가압공기부상법은 물 속에 공기를 과포화시킨 후 노즐을 통해 재분사할 때 발생하는 압력차에 의해 미세기포가 발생함을 이용하여 유기물을 분리하는 공법이다. 그러나, 가압용 장비 및 반송수가 필요하고, 미생물분리는 불가능한 단점이 있다. 이에 본 연구에서는 미생물살균과 유기물 분리가 동시에 일어나는 플라즈마를 이용한 부상분리기법을 개발하였다. 본 연구에서는 난분해성 용존유기물인 휴믹산 100 mg/L의 플라즈마 공기부상법에 의한 제거능을 확인하였다. 용존성 휴믹산을 입자성 물질로 전환하여 플록을 형성시키고자 알루미늄설페이트(Al2(SO4) $3{\cdot}18H2O$)를 100 mg/L 주입하였고, 침출수와 같이 염도가 높은 물을 모사하고자 35 g/L의 염화나트륨을 첨가한 상태에서 방전을 실시하였다. 방전에 사용된 전원은 EESYS사에서 제작한 펄스형 고전압 전원장치를 사용하였고 최대 15 kW의 출력 중 6 kW의 전력을 인가하였다. 전극 한 개는 2 mm 텅스텐봉을 세라믹튜브로 감싼 구조로 총 사용전극은 28개이다. 전극 한 개당 대략 200 Watt의 전력이 소모되며 이 때 최대의 버블이 생성됨을 확인하였다. 전극 1개에서 생성되는 버블의 부피는 14 mL/min 로 측정되었다. 버블의 크기는 평균 70 um이고 가압공기부상법에서 최적공기크기로 제시하고 있는 40~80 um 의 버블은 약 80% 가량 생성된다. 본 연구에서 사용된 반응시스템에서의 물의 높이는 약 500 mm 이고 전체 40 L의 수조가 3개의 벽으로 분리되어 4개의 수조로 분리되었다. 각 수조는 하부에 7개의 전극을 포함하고 있다. 플라즈마 발생시 생성되는 기포는 약 1분 방전 후에 포화농도에 도달하며 방전종료 후 약 4분간 수체 내에 남아있게 된다. 이를 공정에 적용하여 1분 방전 및 4분 휴지의 순서로 플라즈마를 인가하였다. 휴믹산 용액의 유량을 2 lpm 으로 운전하였을 때 최종 처리율은 94% 이고 이때의 대장균 살균능은 99%이다.

  • PDF

A Study of the Improvement Plan and Real Condition Estimation of Fire Protection Safety Management for Power Plants in Korea (국내발전소 소방안전관리 운영실태조사 및 개선방안에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.61-73
    • /
    • 2017
  • The Fukushima Nuclear Disaster in 2011 and California Power Failure in 2001 are examples of the importance of the power plant safety management that caused huge national loss with a power-related mass casualty incident. In a situation where humans cannot live without electricity, efforts to strengthen the systematic firefighting safety management in power plants that produce electricity with large amounts of hazardous materials as fuel, such as nuclear energy, coal and gas, are essential to protect life and prevent property loss and stable economic growth from fire explosion accident or radiation leak due to the negligence of safety management and natural disasters such as earthquakes, which has recently become an issue. This study examined the operating situation of firefighting safety management in power plants with firefighting officials employed by five power generation companies including Korea Southern Power Co., Ltd. and Korea Hydro & Nuclear Power Co. Ltd., which are in charge of the domestic power supply. As a result, for the systematic firefighting safety management of power plants, improvement plans were drawn, including the development of an effective business manual and a comprehensive management system, the substantiality of firefighting safety education, and the strengthening of seismic designs to prepare for earthquakes.

Evaluation of the Actual Conditions for the Construction of a Firefighting Safety Management System in Domestic Power Plants (국내발전소 소방안전경영시스템구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-wook
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.89-98
    • /
    • 2018
  • Fire accidents in foreign countries, like the accident in a thermal power plant in Beijing, the accidents in domestic power plants, including Boryeong Power Plant in 2012 and Taean Power Plant in 2016, a disaster in a nuclear power plant in Fukushima in 2011 or the large-scale power failure in California in 2001 are safety accidents related to electric power, which caused losses in the people's stable lives and the countries. Electricity has an absolute impact on the people's life and the economy, so we can easily expect the serious situation affecting economic growth as well as direct damage to the protection of the people's lives and the losses of properties, if there are fire or explosion accidents or radioactive leak because of negligence in safety management, or problems because of natural disasters like an earthquake in power plants that generate electricity. In this study, it was drawn the improvement of the organizations exclusively in charge of firefighting, the operation of a program for the improvement of professional competency, the development of a customized firefighting management system for plants for systematic firefighting safety management and the improvement of the earthquake-proof correspondence system, which has recently become an issue, as measures for improvements through a survey of the actual conditions concerning the necessity of the construction of a firefighting safety management system for power plants with five power generation companies, including Korea Southern Power Co., Ltd., and the persons in charge of firefighting safety Korea Hydro & Nuclear Power Co., Ltd.

국방예산(國防豫算)의 국민경제적(國民經濟的) 효과분석(效果分析)과 지출구조(支出構造) 개선방안(改善方案)

  • Hwang, Seong-Hyeon
    • KDI Journal of Economic Policy
    • /
    • v.20 no.3_4
    • /
    • pp.175-222
    • /
    • 1998
  • 본 논문에서는 우리나라 국방예산 운영의 국민경제적 파급효과에 대한 실증분석에 기초하여 국방예산 규모논쟁에 대한 검토, 지출구조의 개선방안, 그리고 지출구조 개성을 위한 국방부문의 효율화 방향을 제시하였다. 실증분석을 위해 Feder-Ram 2부문-외부효과모형에 기초하여 1970년대 이후 총국방비 운영유지비 방위력개선비 등 3가지의 국방부문 지표를 이용한 실증분석 결과, 방위력개선비가 국민총생산에 대해 유의한 정(正)의 효과를 갖는 것으로 나타났다. 총국방비의 경우 유의성이 없었으며, 운영유지비의 경우 유의한 부(負)의 효과를 갖는 것으로 나타났다. 국방예산 규모논쟁과 관련하여, 최근 GDP 대비 국방비 비중과 안보위협을 고려한 국가군별 비교 등을 통해볼 때, 지금까지의 우리나라 국방비규모의 상대적 비중이 하락하는 추세를 더 이상 기대하기는 어렵다고 보는 것이 현실적인 인식이라고 판단된다. 이제 국방예산 관련 논의의 초점은 상대적 규모를 포함하여 국방예산규모 자체보다는 국방예산의 지출구조와 내역에 맞추어져야 하고, 국방예산 운영의 낭비사례를 방지하고 효율성 투명성을 높여서 적절한 지출구조와 배분내역 방식을 이루는 것이 되어야 한다고 판단된다. 국방예산 지출구조의 개선을 위해서 투자비 성격의 방위력개선비 비중을 높이는 예산구조상의 개선이 매우 중요한 과제이다. 이를 위해 각종 경사경비에 대한 영점기준의 검토작업과 더불어 인력과 장비의 대체, 인력구조의 조정 등을 통해 기술집약형 전력구조를 지향하는 보다 근본적인 구조조정노력이 이루어져야 할 것이다. 미래전 양상에 대비한 군 첨단화의 핵심인 해상방위력 및 항공력 증강 등이 필수적이며, 지상군 위주에서 상대적으로 해 공군 중심의 군 구조로 개선되어야 할 것이다. 구조개선의 완급조절과 군별배분의 수평적 구조개선을 통해서 예산규모의 커다란 증대 압력 없이 추진 할 수 있는 구조개선은 시급히 실현되어야 할 것이며, 구조조정 재원의 상당부분은 군 내부의 낭비사례를 막고 생산성을 획기적으로 제고해서 확보할 수 있어야 할 것이다. 국방예산 운영의 효율성 투명성 제고를 위해서는 군 내부 자원관리기능이 강화되어야 하고, 군조직 운영에 있어서도 민간부문에 상응하는 경영효율성 개념의 과감한 도입이 요구된다. 지금까지의 '국방전력 극대화'를 위한 군인중심의 획일적 폐쇄적 군조직 운영에서 벗어나 조직 인사 예산 운영 전반에 걸친 경영혁신이 이루어져야 한다. 국방부문에 경영효율성 개념을 도입하여 경영혁신을 이루어나가는 주요 정책방향은 일부 기능 조직의 민영화 및 민간위탁의 확대, 민간전문인력의 활용도 제고, 자율적 책임경이 필요한 부문을 대상으로 한 "책임경영사업소(Agency)제도"의 도입 등이다. 또한 유사기능을 갖는 조직과 각군별로 별도로 설립되어 중복되는 기능을 수행하는 기관을 통폐합해야 할 것이다.

  • PDF

The Activity of Standard and Fast SCR over V-based Catalysts Supported on Various TiO2 (다양한 TiO2에 담지된 바나디아 촉매의 표준 및 빠른 SCR 활성)

  • Ji Eun Jeong;Yeon Jeong Jo;Inyoung Lee;Jeongkeun Lee;Chang-Yong Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.584-589
    • /
    • 2023
  • The physicochemical properties of VOx/TiO2 catalysts with different TiO2 supports were analyzed, and SCR reactions were performed. VOx/TiO2 catalysts were prepared by impregnation using anatase TiO2, which was manufactured by Sigma Aldrich and prepared from TiOCl2 and titanium isopropoxide (TTIP) as a precursor. They are denoted as VS, VC, and VP. The specific surface area of the VS was 1/10 or less of that of the VC and VP, and the dispersibility of vanadium oxide was relatively low. As a result of XPS analysis, the ratio of adsorbed oxygen was higher in VS and VP with Ti3+ than in VC. In VC and VP, vanadium mainly existed in V4+ and V3+ states in relation to the dispersibility of vanadium oxide. The amount of adsorbed oxygen contributed more to NH3-SCR activity than vanadium oxide dispersibility below 250 ℃, while vanadium oxide dispersibility contributed more to activity beyond 300 ℃. The fast SCR activity in all three samples was the highest at NO2/NOx = 0.5, followed by VS < VC < VP samples. It was determined that the dispersibility of vanadium oxide had a significant effect on fast NH3-SCR activity.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF