• 제목/요약/키워드: 전동기구동해석

Search Result 171, Processing Time 0.031 seconds

A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor (영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.40-51
    • /
    • 2009
  • To analyze influences under open faults in switching devices of the PWM inverter and under the isolation between the inverter and motor terminal, a faulty model for the inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control AC motor, it can not be used under open faults in switching devices since the 3-phase balanced condition is no longer hold under the open fault and it is not easy to obtain motor input voltages in open phase from the pole voltage. To deal with this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is derived by using the line voltage of motor according to switch open, which can be effectively used for performance evaluation of the diagnostic algorithm. The validity of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335.

A Study on Stator Winding Turn-Fault Model for Fault Diagnosis in Inverter-Driven Permanent Magnet Moor Drives (고장진단을 위한 영구자식 동기전동기의 권선 단락에 의한 고장모델 연구 및 특성해석)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.18-28
    • /
    • 2009
  • To analyze influences under faults caused by a stator winding short and to evaluate an effectiveness of a diagnostic algorithm a faulty model for an inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control the motor, it can not be used in the analysis of a faulty motor since the 3-phase balanced condition is no longer hold under the fault caused by a stator winding short, and thus, it is very difficult to obtain motor input voltages from the pole voltage of an inverter. To overcome this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is proposed by considering the line voltage of 3-phase variables. The effectiveness of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335 and motor built to allow a partial short of inter-turn.

Design and Characteristic analysis of Hollow Type Motors for Robot Arms (로봇 관절용 중공모터 설계 및 특성 해석)

  • Kim, Kyung-Su;Lee, Sung-Ho;Cha, Hyun-Rok;Lee, Kyu-Suk;Park, Byung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.814_815
    • /
    • 2009
  • 본 논문은 로봇관절 구동 및 제어에 활용될 중공모터의 설계 및 특성해석에 대해 연구하였다. 로봇관절에 사용될 중공모터의 경우고 토크출력이 요구될 뿐만 아니라, 저속에서 제어 및 구동 신뢰성이 높은 운전특성이 요구된다. 또한 로봇 관절에 활용하기 위하여 배선처리가 간편한 중공타입의 구조가 요구된다. 따라서 우리는 로봇 구동 및 경량화가 가능하도록 유성기어와 결합이 가능한 외전형 타입의 영구자석 동기전동기의 설계 및 특성해석을 하였다. 먼저 로봇 관절에 적합하도록 FEA 기법을 이용하여 설계하였으며, 실제 시작기 모델을 제작하여 성능실험을 통해 제안된 모터의 특성을 분석하였다.

  • PDF

Analysis of the Chopper Fed DC Motor Control System Using State Space Averaging Method (상대 평균화법에 의한 초퍼구동 DC모터 제어 시스템의 해석)

  • 정헌상;백형래;이상일;조금배;유권종;이완권
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.5
    • /
    • pp.56-64
    • /
    • 1994
  • 본 논문은 직류초퍼구동 전동기 제어시스템을 해석 대상으로 하여 전류 연속모드와 전류 불연속모드의 양 모드 동작시에 있어서의 해석을 상태변수법과 상태평균화법을 적용하여 해석하였으며 두 해석 방법의 결과를 비교 검토함과 동시에 상태평균화법에 의하여 시스템의 해석이 근사적이지만 해석이 용이하다는 것을 나타내고 있다. 또한, 본 시스템의 궤환루프 제어시스템에 있어서 상태평균화법을 이용한 평형점 근방의 근사 선형화 방법을 적용함으로써 전달 매트릭스의 형태로 동특성을 표현할 수 있으며, 이것을 이용한 선형 제어법을 적용하여 궤환루프 제어계의 설계기법을 제시하고 있다.

  • PDF

Module-based Modeling Method of $3\Phi$ Phase-Controlled Rectifier System for DC Motor Drive under Matlab/Simulink environment (Matlab/Simulink 환경하에서 3상 위상제어 정류기-DC 전동기 구동시스템의 모듈별 모델링 기법)

  • 김상민;한우용;이창구;김성중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.15-21
    • /
    • 2000
  • This paper presents the modeling method of $3\Phi$ phase-controlled rectifier for the DC motor drive in MATLAB/SIMULINK environment. This method has no need to extend the system mathematically and thus it's easy to integrate the various systems. The whole model consists of $3\Phi$ phase-controlled rectifier block, DC motor block and speed/current controller block. The simulation results show that the model outputs are almost similar to those of the real system and therefore that the presented method is suitable for the research of the closed-loop controlled power electronic systems.

  • PDF

A Study on Revolving Characteristics According to Stator Shape in 5MW Class Brushless DC Motor for Ship Propulsion (선박용 5MW급 BLDC 추진전동기의 고정자 형상에 따른 회전특성에 관한 연구)

  • Kim, Dong-Sok;Sung, Il-Kwon;Kim, Jang-Mok;Park, Gwan-Soo;Kim, Han-Deul;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.47-49
    • /
    • 2005
  • 최근의 선박 추진시스템은 기존의 엔진, 터빈 둥의 구동 원에서 선박의 발전기로부터 선체 외부의 프로펠러와 일체형으로 구성된 모터를 구동하여 추진하는 전기추진식으로 변화되고 있다. 특히, 히토류계 영구자석재질의 발달로 인하여 대형선박의 추진을 위한 대용량 자석계자형 BLDC와 영구자석형 동기전동기의 설계 연구가 활발히 이루어지고 있다. 그러나 여전히 MW급 대용량 BLDC 추진전동기의 설계 연구는 미흡한 실정이다. 이에 본 연구에서는 5MW급 대용량 BLDC 추진전동기 설계 연구를 진행하였으며, 그 결과 슬롯 수에 의한 고정자 형상이 다른 3가지 타입의 인버터 내장형 MW급 모델을 설계하였다. 그리고 이들 모델들을 정자계 유한요소법을 이용하여 해석함으로써 고정자 형상에 따른 회전특성을 분석하였고, 이를 바탕으로 본 설계 조건에 적합한 고정자 형상 설계 방향을 제시하였다.

  • PDF

The Vector Control of SLIM Considering End-effect (단부효과를 고려한 편측형 선형유도전동기 벡터제어)

  • 조금배;임홍우;장용해;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.395-403
    • /
    • 2002
  • The advanced space vector PWM is Implemented for the control system using high arithmetic performance microprocessor such as DSP. It is difficult to realize the complicate SLIM which is applied to SVPWM system, but widely used in vector control system or servo control system for AC motor because of its high performance in current control. In this paper, we use the dynamic characteristic analyzing method that can calculate efficiently the end effect by using equivalent circuit methode in the operating SLIM system modeling and examine the dynamic characteristics of SVPWM with PI controller.

Regenerative Power Drive of a Induction Motor Based the Field Acceleration Method (FAM 법에 의한 유도형 서보 전동기의 전력회생 구동)

  • Hong, Soon-Ill;Jeong, Seoung-Hwan;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1198-1200
    • /
    • 2005
  • 본 연구는 스파이랄 벡터에 기초한 유도 전동기 모델의 해석을 나타내고 이 해에 기초한 자계가속법(Field Acceleration Method)에 의해 순시 토크제어와 회생전력 해석을 나타내었다. 전압지령형의 전압 PWM 인버터에 의한 유도 전동기의 속도 서보시스템을 설계하고 가감속시의 소비(회생)전력을 측정하여 실제 시스템에서 전력 절약정도를 검토하였다. FAM법에 의한 실험을 행하고 유효성을 확인하였다.

  • PDF

Analysis on the Effect of LCR Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter (멀티레벨 인버터 구동 고압유도전동기에시 발생하는 과도과전압 저감을 위한 LCR필터의 효과분석)

  • Kim, Jae-Chul;Kwon, Young-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.45-52
    • /
    • 2006
  • In this paper, we analyze on the effect of LCR filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage that it was occurred in inverter appears transient overvoltage at the motor input terminal. the transient overvoltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of transient overvoltage appears more serious in high voltage induction motor than low voltage induction motor. We selected LCR filter for reduction of the transient overvoltage. Consequently, we demonstrated that the LCR filter connected to the invertor output terminals greatly reduces the transient voltage stress and ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

The Theoretical Analysis for Instability I. M Driven by VVVF Source (가변주파수 전원으로 구동되는 유도전동기의 불안정 현상에 관한 이론적 해석)

  • Baek, Soo-Hyeon;Kim, Yong
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.57-63
    • /
    • 1993
  • In this paper, we study the effects that the variations of machine parameters and frequency of which affect the instability occured in induction motors when operated at low speed or light load, by obtaining the locus of dominant root for the characteristic equation.

  • PDF